Question about Konica Minolta bizhub Office Equipment & Supplies
belt unit is damaged.Reinstall or reconnect IDC sensor shutter or connector for every color unit and clean the sensors when vacuum cleaner after remove the all imaging units and the transfer belt unit
Question about Konica Minolta bizhub Office Equipment & Supplies
...IDC sensors are located under the transfer belt on the right sid eof the machine. Belt must be removed to clean sensors. Once belt is removed sensors are located on a black plastic frame and have ...
Question about Konica Minolta bizhub Office Equipment & Supplies
where is the IDC front sensor in konica minolata C450 there is a problem in the sensor but m unable to find which one is the IDC front sensor Located under the transfer belt, which mean the belt has ...
...? All density readings taken from the density pattern produced on the Transfer Belt are 0.5 g/m2 (IDC Sensor photoreceiver output) or less during max. density adjustment (Vg/Vdc adjustment). ? All ...
Question about Konica Minolta bizhub Office Equipment & Supplies
...IDC/Registration Sensor in konica minolta bizub c450 Remove the transfer belt. Then right below the fusing unit right where the edge of the transfer belt is located when normal installed right below ...
Question about Konica Minolta bizhub Office Equipment & Supplies
...C-550 I appear P. -21 code After I changed the UNIT appeared to me Code P. -5 What should I do Clean the Front and Rear IDC sensors,open and close the front door,run an image stabilization
Question about Konica Minolta bizhub Office Equipment & Supplies
...the laser output. • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment. Replace the PWB Print Head ...
Question about Konica Minolta Office Equipment & Supplies
where is the IDC sensor part in the machine am unable to find the part of the IDC sensor as i dont know which one is the IDC sensor Well first I need to know the model #####?
...run tcr gives error code 6. machine says operating,but does nothing. Check the following , Dirt of IDC sensor, Clean up the IDC sensor, if no then Printer control board abnormality Replace ...
...DC output is 0 or lower. Associated Parts: • Printer control board (PRCB) • Developing unit /K • IDC sensor (IDCS) • IDC shutter solenoid (SD3) Remove the black (K) Drum. behind and toward the ...