Ruud UAKA030 Air Conditioner "wire condensor" Questions

Ad

...wire leads off the condensor 2- Brn and 1-Red (New Capacitor Labels are as follows (C) (Fan) and (HERM)) How do I hook this up ? Please Help ! -Thanks the wire diagram should tell you how. it all ...

Ad

Question about Weather King Heating & Cooling

1 Answer

...wire the condensor fan. If new motor is 4 wire verses 3 wire use seperate capacitor between brown wires and don't use terminal on 3 pole cap. If this motor has a white strip on one brown wire you can ...

Ad

Question about Heating & Cooling

1 Answer

...wire system red and white Red goes to the t-stat RH and white goes to W for heat furnace. If it as A/C unit Red goes to one of the wires at the condensor(pick one) and the other side to Y at the ...

...condensor fan stops and compressor keep on running.What can cause this problem? Check all your wires and connections of your condensor fan. If there are damaged or overheated wires or

wire diagram from T-stat to Air-Handler then cond unit green goes to g on air-handler,white goes to w on air-handler yellow goes to outside condensor, red from air-handler goes to rh-rc on thermostat,

Question about Goodman Heating & Cooling

1 Answer

condensor fan motor i replaced my condensor fan motor. the new one has four wires and the old one had only three. what do i do and the color code is different you have a reversible motor or a two ...

Question about Amana Heating & Cooling

1 Answer

...is the condensor fan motor still turning when it stops cooling. if not check low voltage wires to condensor, furnace and ...

Question about Heating & Cooling

1 Answer

...Condensor unit won't come on except if you push down the contactor manually. Over the winter the inside heater and air handling part of the split system was replaced with a Goodman unit. The outside ...

Question about Heating & Cooling

2 Answers

...wire leads off the condensor 2- Brn and 1-Red (New Capacitor Labels are as follows (C) (Fan) and (HERM)) How do I hook this up ? Please Help ! -Thanks Comments: Aug 27, 2009 - I hooked it up based on ...

Question about Whirlpool Heating & Cooling

1 Answer

...WIRING AND REPLACE CAPACITER STILL SAME RESULT ? check wiring for condensor fan motor,make sure wire nuts and connections are tight,if still no luck then i'm afraid you have a bad condensor fan ...

Not finding what you are looking for?
Ruud UAKA030 Air Conditioner Logo

56 questions posted

Ask a Question

Usually answered in minutes!

Top Ruud Heating & Cooling Experts

Brad Brown

Level 3 Expert

19187 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

john h

Level 3 Expert

29494 Answers

Are you a Ruud Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...