...tube & operates the pressure switch turning off the inlet valve. Either the pressure switch is faulty or, more likely, the tube has a hole(maybe tiny) in it and is not allowing the pressure to ...
Question about Fisher and Paykel Washing Machines
...runnjng. Strong flow = No blockage. Poor flow = remove pump & hose & check for blockage. If flow is ok then check pressure tube and if all is ok then it will have to be a control board
Question about Fisher and Paykel Washing Machines
...amp;P service rep believed it to be an electronics fault which only a service could fix. Is this the case and would be the exact problem? Could it be fix at home? Fault code 39 is a pressure tube ...
Question about Fisher and Paykel Washing Machines
amp; paykel washer will not allow water in to fill the machine Hello, unplug the washer and take the control panel out to access the water level switch again. Remove the pressure tube that goes to the
Question about LG Washing Machines
...amp; filter "PE" error: Water Level Pressure Sensor Error. 1) Verify that the black tube is still connected to the Water Level Sensor at the top of the washer---and to the Air Bell at the bottom of ...
...amp; Solution = The water level sensor is faulty. Change the water level sensor. (remove pressure tube and blow through it to make sure it is clear first) ERROR E2 PROBLEM inlet valve is filled with ...
tube between the controls & air chamber causing the lack of pressure. Sometimes the electronic GW/LW/MW models of F & P machines go faulty where the transducer (electronic sensor on the board)
...even refill for a new load. aplastic tube leading from bottom of tub goes to a pressure switch and is probably plugged w lint. the machine tthinks its full & Wont prceed. clean tube & ...
Question about Fisher and Paykel Washing Machines
...clear tube with a clip, remove & blow into the "tube only" in a lot of cases this will hopefully eliminate fluff caught in the chamber. I do not think there is any other major issues here - ...
Question about Fisher and Paykel Washing Machines
fisher & Paykel gw711 excellence keeps filling and overflowing when first turned on to initial wash cycle the clear pressure tube is blocked, you need to blow air down the clear pressure tube hose