...to achieve the proper burning of the heater with the least amount of fumes. Thanks M Cramer ...
...for service parts http://www.bealsmotor.com/Desa%20Hot%20Surface%20Manual.pdf for the service manual My guess is the plug is dirty or air pressure is off causing the no ignition ...
...www.reddyparts.com . If the air pump pressure is correct, then check the following: Cracked air line preventing correct pressure at the nozzle. Cracked nozzle adapter preventing the fuel from being ...
...are at www.reddyparts.com . Check your heater over thoroughly for the exact model of your heater. "Pro 200" only designates a style and not all parts interchange from one PRO 200 to the
Question about Reddy Heating & Cooling
...www.reddyparts.com website. This pressure setting directly affects fuel delivery & fuel atomization This nozzle rule will only apply if everything is correct as far as fuel delivery applies. The pump ...
...recommended annual replacement because as the nozzle wears the cone puts out a spray rather than a fog and combustion suffers. Also set the air pump pressure. ...
...www.bionaire.com On my Bionaire BCH9212, I found two zener diodes shorted on the power board that has the relays on it. The type number is 1N4739A which is a 9.1 volt, 1 watt Zener diode. Zd1 and Zd2 ...