...will not switch on. CH-52 Communication error between inverter PCB and main outdoor unit PCB. Check wiring fuses and LEDs . If OK either inverter or main PCB defective what do i do ch 52 on ...
LG error CH 64 Hi, My Lg art cool display de error CH 64, anyone know the problem? thanks What is the model of the unit?
Error code CH 02 for a ceiling cassette model LTUH186ELF1 The pcb is working,air flow sensor also working CH02- Means "Indoor coil sensor is faulty or not connected" WHAT ARE SOLUTION THE ERROR CODE ...
What is error code ch o5 CH-05 Communications Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4
CH-10 error code in LG a/c.Modal-LBUC609RSA5 i need to fix this problem so pales give the answer,CH-10 error code in LG a/c RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure ...
...error code CH 05. no heating or cooling. cheers. CH 5 on these machines indicates a communications error between the indoor and outdoor units. Generally, it will require a replacement outdoor board ...
Question about LG Heating & Cooling
...error code CH 46 and with no response at all. How can I fix it? Thanks for your help in advance! LG with 1 - 3 units. All 3 units are flashing with error code CH 46. And no response when press the ...
...Ch is usually followed by another error code if there is a problem with the unit. If you have no other errors this is a reminder to clean the filter that will appear every 366 hours of use. Clean the ...