...DC controller PCBs. COPIER>I/O>DC-CON<DC-CON (5/7)> P020 xxxxxxxxxxxxxxxx=runs from left to right 15>0 ADDRESS=P020 BIT- 0- zero-cross signal - 1- heater trigger 1 signal 0: ON 2- ...
Question about Canon Office Equipment & Supplies
...disengaging motor and J1100 for the DC controller PCB. 2. Replace the developing disengaging drive assembly. 3. Replace the DC controller PCB. Calibrate the printer after replacing the DC
...DC controller PCB. Replace any damged parts. 2. Replace the fuser drive assembly. 3. Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. Best regards, ...
I have DC 12 Xerox and when I am give an print to fiery Network Controller Error is display on Printer Display NVM CHANGE 752-008 = 2 702-031 = 1 702-032 = 30 702-037 = 0 702-038 = 0
...DC controller connectors J1010, J1012, and J1021. Reseat laser/scanner unit connectors J101, J102, J5001A, and J5001B. 4. Replace the flat cable. 5. Replace the laser/scanner unit as necessary. 6. ...
dc controller PCA (location J98) 3 Replace the main motor. See Main motor. 4 Replace the dc controller PCA. See Dc controller PCA. 59.A or 59.4 print-cartridge-motor failure (LJ 4250, 4300, 4350 only)
...DC controller connectors J1022, J1026, and J1027. Reseat laser/scanner unit connectors J101A, J101B, J5001A, J5001B, and J5020. Replace the laser/scanner unit as necessary. Replace the DC controller ...
...DC controller PCB. Set the tester range to x1KW, and measure the resistance between J104B-2 and J104B-1. Is it about 500W? NO Check the wiring from the DC controller PCB to the total copy counter; if ...
Question about Canon Office Equipment & Supplies
DC controller PCB is faulty. Caution- To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR. Action ------------------------------------------------------------
Question about Canon Office Equipment & Supplies
...DC CONTROLLER PCB ASSEMBLY Subject: Error Code E020-0XA0, E020-0XA2, E020-0XA8, and E020-0XA9 Detail: The error code of E020-0XA0, E020-0XA2, E020-0XA8, or E020-0XA9 is displayed. A component on the ...
19 questions posted
Usually answered in minutes!
2,244 Questions
2,149 Questions
1,862 Questions
1,594 Questions
1,302 Questions