ac drive board · Defective main board · Fusing harness shorted To reset code : 1. Turn on the main switch. 2. Enter "71" by using the numeral keys. 3. Press and hold the Clear/Stop key until
ac drive board · Defective main board · Fusing harness shorted To reset code : 1. Turn on the main switch. 2. Enter "71" by using the numeral keys. 3. Press and hold the Clear/Stop key until
...(Thermistor Connector and AC Connector). 2.Replace the Fixing Main Thermistor (Film Unit). 3.Replace the Fixing Assembly. 4.Replace the DC Controller PCB Hope this may help you to get clear.
AC power for the machine.The power should be 120VAC +-10%. Make sure it has its own dedicated power and not sharing power with any other device. If the power checks to be good, follow the steps below.
Question about Toshiba Office Equipment & Supplies
...3) Check if the thermostat is blown.(4) Check if the connectors on the IH board are disconnected (AC input connector and LGC I/F connectorCN455/456).(5) Check if the IH board or the switching power ...
3) Check if the thermostat is blown. (4) Check if the connectors on the IH board are disconnected (AC input connector and LGC I/F connector CN455/456). (5) Check if the IH board or the switching power
...AC frequency was detected at over 66Hz or below 45Hz, and the zero cross signals are not detected within a certain period within 500 ms after the main power switch has been turned on. Possible causes ...
Question about Toshiba Office Equipment & Supplies
3) Check if the thermostat is blown. (4) Check if the connectors on the IH board are disconnected (AC input connector and LGC I/F connector CN455/456). (5) Check if the IH board or the switching power
AC drive board defective (check the triac) · Fusing thermistor defective · Main control board defective For safety reasons, Level A service calls cannot be cleared by turning the main switch
94 questions posted
Usually answered in minutes!
401 Questions
267 Questions
218 Questions
181 Questions
164 Questions