...pool heater pilot says lit but wont fire any more replaced pilot generator pilot that whole unit nice pilot but wont fire problem isnt with the pilot generator. you have either an open safety withing ...
pilot wont stay on and ive replaced the My heaters pilot wont stay on and ive replaced the thermocoupler and pilot assembly and replaced the gas valve and it still wont stay lit what could cause that?
...pool heater pilot wont stay lit wont stay lit after 1 minute pressing button and switching to on position wait 5 - 10 minutes, turn off gas and on to off still nothing dirty pilot tubing or need new ...
pilot light wont ignite...i followed directions behind the door but burners wont light up. it seems like gas is not flowing into the burner...its a teledyne laars spa/mark DR-175 check the silver line
...pilot does not stay lit If this is a M/V heater you must have at least 400mv/dc to hold the pilot valve open. Check to make sure that the pilot is lighting, then hold the pilot valve down for about a ...
pilot wont light //suspect corrosion, connections.. If your pilot assembly is corroded, you will have trouble lighting the pilot. I would highly recommend replacing the pilot assembly. By doing this, ...
...pool and spa heater i have replace the pilot assembly and the theremal couple and the ignitor i have a great flame on the pilot but when i turn the valve to on the burners wont lite the thermastats ...