Question about Tally Office Equipment & Supplies
...fault message: Hammer Voltage has been replaced, in the T6218, with: Hammer Voltage 1 There is a new fault message for the T6218. It is: Hammer Voltage 2 Explanation: A high resistance coil fault has ...
...: hammer voltage 2 it prints for about two minutes then starts slowing down and then stops printing showing an error of : hammer voltage 2 My Tally T6218 Printer had fault "Hammer voltage 1" and ...
...hammer coils. Note: This fault message will have been preceded by printing slow-down attempts associated with On-The-Fly thermal monitoring of hammer bank temperature. Check blower underneath ribbon ...
fault with one of the hammer coils, this would need investigating, other possible causes;Faulty / damaged ribbon cableFaulty main boardUpdate firmware, the error should change to a more
Question about Tally Office Equipment & Supplies
...hammer coils. Note: this fault message will have been preceded by printing slow-down attempts associated with On- The-Fly thermal monitoring of hammer bank temperature. Check the hammer bank for ...
Question about Tally Office Equipment & Supplies
...the ribbon cable from the main board to the hammer bank for damage and ensure the cable connects correctly. There may be a fault with the main board or with the interconnect board on the hammer
HAMMER VOLTAGE 1 FAULT, CAN U HELP ME WHUCH IC OR CHIP FAULTY It could be the problem with your Hammer bank/ Hammer bank cable or MLC, Some cases dusty hammer bank . Hammer 1 is usally the logic board
Question about Tally Office Equipment & Supplies
...HAMMER VOLTAGE 1 ERROR indicate? FAULT STBCNT 1 There is a short on the hammer drive circuit. It can be caused by the HammerBank TALLYGEN 093524 HAMMERBANK T6306 Refurbished The Main Logic, the link ...
...fault before calling your authorized service representative: 1. Set the printer power switch to O (Off), wait 15 seconds, then turn the printer on again. Run your print job again. If the message does ...
...hammer coils. Note: this fault message will have been preceded by printing slow-down attempts associated with On-The-Fly thermal monitoring of hammer bank temperature. Solution: Check the hammer bank ...