...240V timer. Intermatic make a freeze control for 1 or 2 circuits. Intermatic page showing Pool and Spa timers ...
Question about Electric Hardware & Accessories
...wire-EH40-hot-water-heater-timer.html There are two hot wires in 240V circuit because every circuit requires two wires to complete the circuit. Hot wires from breaker connect to terminal 1 and 3. ...
...240V clock motor. Wiring diagrams are shown on links below: http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html http://waterheatertimer.org/images/T-104-240-Volt-400.jpg ...
Question about Intermatic Hardware & Accessories
...240V and b) the timer mechanism is ok ... so clock motor is probably bad. 4) If manual override snaps crisp but pool timer does not turn on, then then circuit breaker could be bad, wire is loose, ...
...240V 24 hour is correct replacement timer http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx 5) Amazon sells new T104 for 50$ which is cheaper than some folks are ...
...240V circuit. Load1 wire connects to T104 terminal 2 Load2 wire connects to T104 terminal 4 Terminals 2 and 4 have power whenever timer turns ON 4) Definition: In electric wiring, Line means power ...
...240V.pdf http://waterheatertimer.org/How-to-operate-and-set-T104-timer.pdf Open following link if you have T104R201 with fireman's switch ...
...wire to Load connects to pole X Timer can control 240V Load if removable bridge between poles L and 1 is taken out. Timer clock is still 120V: so 120V Hot still connects to pole L and neutral from ...
...240V, then no change is needed. If circuit breaker that supplies power to timer is 120V, then change jumper on back of timer to 120. Timer mechanism snaps out of box using thumb spring located top ...
i have a paragon timer model 4004-20 and do not have a wiring digram for it . can you help http://waterheatertimer.org/Paragon-timers-and-manuals.html I don't find the Paragon 4004-20 listed in manual