hayward heater not staying lit i have a h series millivolt hayward heater. i have bypassed the high temp limit switch and the pressure switch due to a fault and need replacing. the igniter sparks and ...
Question about Jandy Pool & Spa
i have a lite 2 the pilot is lit but the bruners wont lite up pump must be running. or filter is plugged. or pad pressure switch it's located on the plumbing inside of the heater and has 2 wires going
Where is a flame sensor located on a laars lg millivolt pool heater first of all millivolt heaters dont have an actual flame sensor. flame rods are located in the electronic ignition models. The only
larrs lite llg natural gas heater - the only way i can light the pilot is to remove the valve knob and push the valve pin in manually - that lights the pilot everytime but when the pin is released, ...
Millivolt system,troubleshooting them is often not as simple, if you go by the book using a Volt/Ohm meter to test the generator and gas valve. The Pilot Generators are less tricky as they all put out
I have a raypac RP2100 model # CR185MN ASME. I want to know how many millivolts are required to operate the gas valve ? Generally, it should operate properly at around 500mv. There are different gas ...
heater goes on for 5 minutes ,then shuts off,just changed thermopile generater,changed fusible link 2 months ago and now its burned again, read it might be flame rollout,there is alot of soot,what do ...
what is the thermopile That is the same as a pilot generator. it is a thermal sensor right next to the pilot burner itself, it is touching the pilot flame. Its purpose... Is to get hot and then with ...
Question about Napoleon Pool & Spa
Millivolt system,troubleshooting them is often not as simple, if you go by the book using a Volt/Ohm meter to test the generator and gas valve. The Pilot Generators are less tricky as they all put out
172 questions posted
Usually answered in minutes!
193 Questions
177 Questions
72 Questions