FL4 code A FL-4 error is an ignitor failure. There are three things that need to be checked to correct the issue. First is the ignitor. Replace if broken or burnt or cracked. Second is the 220/120 vac
Question about Pool & Spa
...FL4 error code but the hot surface ignitor works if I run power to it from an outlet. Maybe an open circuit at igniter? Direct power at igniter, does not make it problem free when installed on the ...
...FL4 code? I have a Jandy Lite 2 that has an FL4 Code. Igniter is new. Heater works for a while then shuts down and won't ignite. It makes one click noise then displays FL 4 code. Any thoughts on how ...
...code fl4 - hot surface igniter problem- I tapped the gas valve and checked the fuse , still getting the same code. Igniter circuit is open. Check fuses on igniter wires. Identify and correct loose or ...
fl 4 code fl4 = Igniter Failure A. Igniter circuit is open: Check fuses on igniter wires B. Element has a fine crack in it: Replace igniter C. Igniter fault: Replace igniter
Question about Jandy Pool & Spa
FL4 error code and in-line fuses were blowing, replaced the R0367100 igniter (old one missing the tip) and fuses, but still blowing the 2 fuses and getting the 04 code. no more details that would make
fl4 code i replace the ignator but the code is still present i want to know if the conversion plug is the problem Thank you for posting your question here on Fixya.com. If you follow the two wires up ...
...ignition sequence and function normally. NOTE: The manual also says that an FL4 code should be fixed by a professional. ...