Goodman CLQ36AR49 Air Conditioner "low pressure reading" Questions

Ad

Question about Carrier Heating & Cooling

1 Answer

Low pressure reads High. High Pressure reads low??? Your gages are hooked up backwards, try switching them

Ad

Question about Carrier Heating & Cooling

1 Answer

Low Pressure reads HIGH. High Pressure reads LOW??? Not cooling much. stuck in heat mode tap on reverse valve lightly

Ad

Question about Goodman Heating & Cooling

2 Answers

...low pressure will not read over 55-60psi and high pressure will not read over 200psi even when adding freon day or night Inefficent compressor Make sure your tank has enough pressure to to get low ...

Question about Goodman Heating & Cooling

1 Answer

...low and high pressure readings what should the low and and high readings be for a 4 ton 13 seer goodman AC 65to 78 psig on low side 210 to 270 on high side. higher values when house is

Question about Goodman Heating & Cooling

1 Answer

...and high sides while the machine is running, partially block the outdoor fan until the high pressure reaches 270 psi, the low pressure should be 70 psi at this time. This should be true within 10

Question about Haier Heating & Cooling

1 Answer

low pressure reading high. Would appreciate any help I can get. HEY,Kim, connect the red hose with the crooked end on the small line service vale and the blue crooked end to the fat line service valve

Question about Heating & Cooling

1 Answer

...low pressure chamber (left side), utility chamber (middle), and the high pressure chamber (right side). When technicians connect the HVAC manifold gauge to the air conditioner units, he connects the ...

...gauges that can handle the high pressures and have two on a manifold so that you can read suction and high side pressure differences That way you can see if the system is low on gas or over ...

Question about Sanyo Heating & Cooling

1 Answer

Pressure on the low side What is the pressure for freon reading for this model c13632a in the low side at 80 degrees outside temperature . should be above 57psi. Tom

Question about Goodman Heating & Cooling

1 Answer

...the reading for amb, evap temp, pressures high low. Then adjust charge. you need to determine super heat based on dry bulb indoor and outside ambient the read suction line temp vs suction line ...

Not finding what you are looking for?
Goodman CLQ36AR49 Air Conditioner Logo

444 questions posted

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...