1) Not likely the timer is problem, unless there was fire or overheating in timer box. Use nose and eyes to inspect for signs of high heat.
2) Eliminate timer as suspect:
Move wires on timer to test if timer relays have gone bad.
Move terminal 4 to terminal 3
Move terminal 2 to terminal 1
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T1043) Check watt rating of Hayward pump, and voltage.
1Hp motor at 240Volt draws 8 amp, and can draw 6 to 8 times that amount when starting. Up to 100 feet, should be at least 12 gauge wire and double-pole 20 amp breaker. Over 100 feet, 10 gauge wire and 30 amp double-pole breaker is best.
http://waterheatertimer.org/Color-codewire.html#motor4) Intermatic T104 240V timer is rated 40 amps
Can safely handle 1 Hp motor without nearing heat-rating capacity of timer
5) Make sure the motor is wired correctly for 240Volts.
If motor is wired for 120, and 240 is applied, then tripped breaker can result.
If you need further help, I’m available over the phone at
https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
×