Before calling service technician, open following link for Rheem troubleshooting resources.
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.htmlList of causes MIGHT include one of following:
Bad household circuit breaker that powers electronics, or loose wire inside outlet where tankless plugs in.
Tankless fuses and control board.
Water flow rate too low. Minimum .8 gallon required (depending on model)
Tankless inlet filter clogged.
Household aerators clogged at faucets.
Crossover at single-handled faucet
If installed, there can be crossover at mixing valve.
Faulty household check valve, including check valve on re-circulation system if that system is installed.
Restriction in household water line, such as clog at elbow.
Unequal pressure in household hot and cold lines, caused by restriction in hot line. When single-handled faucet turns on, the cold water pressure is higher so hot does not flow and tankless will not turn on.
Loose wire connection inside tankless.
Unit temperature set too high.
Unit temperature set too low.
Water temperature is very hot coming out of tap, so more cold is added, but that reduces amount of hot water flow, so tankless turns off because flow rate is too low.
On some tankless, if water is preheated by solar or other indirect source, the burner will not activate.
High mineral content in water > delime tankless yearly
Misaligned temperature sensor
Low gas pressure. Wrong type of gas. Undersized gas line.
Too many faucets on at same time.
Faulty tankless water valve. Water valve stuck.
Fluctuating household water pressure, for example MUD and PUD district water pressure problems or water well pressure.
Faulty household pressure reducing/regulating valve if installed.
Faulty household pressure tank, if installed -or- pressure tank needs to be installed.
×