Question about 2003 Hyosung GV 125 Aquila

Open Question

Where is the battery on a hyosung 125 aquila?

Where is the battery on a hyosung 125 aquila 2008 model - I'm stumped?

Posted by on

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Hyosung GV 650 Aquila vacuum line routing


Hi, Rudi for this scenario you will need your service manual, parts fiche, and owners manual if you can't find the best tool you ever bought for your Hyosung, despair not, for a mere zero $0 you can download another one.
For more information about your issue and valuable "FREE" downloads that you will need for viewing or printing please click on the blue links below. Good luck and have a wonderful day.
Hyosung GV 650 Aquila vacuum line routing Google Search
vacuum and fuel line routing
HYOSUNG Aquil GV650 Service Manual
HYOSUNG AQUILA GV650 CATALOGUE Manual
HYOSUNG GV650 User Manual

Jan 26, 2018 | Hyosung GV 650 Aquila Motorcycles

1 Answer

2005 Hyosung GV 250 Aquila vent hose routing


Hi, Sherri for this scenario you will need your service manual, parts fiche, and owners manual if you can't find the best tool you ever bought for your Hyosung, despair not, for a mere zero $0 you can download another one.
For more information about your issue and valuable "FREE" downloads that you will need for viewing or printing please click on the blue links below. Good luck and have a wonderful day.
2005 Hyosung GV250 Aquila vent hose routing Google Search
Charcoal Canister
Hyosung Aquila 250 Service Manual
http://www.alpha-sports.com/hyosung_parts.htm
HYOSUNG GV250 User Manual

Nov 29, 2017 | 2005 Hyosung GV 250 Aquila

1 Answer

2005 Hyosung GV 250 Aquila no spark


Hi, Anonymous in the back of the service manual is a wiring diagram otherwise the usual suspects are:
1. Fouled spark plugs.
2. Severely discharged or a damaged battery should have 12.5 volts or more and be able to pass a proper "LOAD" test if necessary, you may have a preliminary reading of 12.5 volts or more but little or zero amperage the battery is faulty and must be replaced, AGM batteries fail in this scenario more so than lead-acid batteries.
3. Check battery terminals for damage or corrosion, check the battery cables at "BOTH" ends for loose, corroded, or broken connectors, "INSIDE" and outside the cable harness, perform connector wiggle test and check cables with an ohmmeter if necessary.
4. Loose connection at ignition coil or plug between ignition sensor and module.
5. Spark plug cables in bad condition, shorting/leaking, spark plug cable connections loose check for spark leakage in the dark.
6. Faulty ignition coil or electronic control module.
7. Faulty pulse coil.
8. Faulty CKP, CMP, or BAS sensor.
9. Faulty ignition switch.
10. Tilt sensor needs a reset.
11. Security alarm failing to disarm needs reset
For more information about your issue and valuable "FREE" downloads that you will need for viewing or printing please click on the blue links below. Good luck and have a wonderful day.
2005 Hyosung GV250 Aquila wiring diagram Google Search
Need help with no spark issue
Hyosung Aquila 250 Service Manual
http://www.alpha-sports.com/hyosung_parts.htm
HYOSUNG GV250 User Manual

Oct 03, 2017 | 2005 Hyosung GV 250 Aquila

1 Answer

Hyosung GV 125 Aquila how to remove the engine


Hi, Barney for this scenario you will need your service/owners manual if you can't find the first and best tool you ever bought for your Yamaha, despair not, for a mere zero $ you can download another one. For more information about your issue and valuable "FREE" downloads that you will need please click on the blue links below. Good luck and have a wonderful day.
http://banici.pl/bam/Tom/GV125/Instrukcje/GV125_SERVICE_MANUAL_EN.pdf
HYOSUNG GV125 PARTS CATALOGUE Parts Catalog
http://www.hyosung-motos.ch/fileadmin/medien/pdf/handbuecher/GV125.pdf
Hyosung GV 125 Aquila 2005
Hyosung GT125 Wikipedia

Mar 20, 2017 | Hyosung GV 125 Aquila Motorcycles

1 Answer

My Hyosung GV250 Aquila has starting problems. It cranks but doesn't turn over. The battery is fully charged. If I push it, it starts and runs perfectly fine.


Hi, Jawahir and the usual suspects are:
1. Ignition Switch not in the "ON" position.
2. Engine Run Switch in the "OFF" position.
3. Discharged battery, needs to be 12.5 volts or better and be able to pass a load test if necessary, check battery terminals for damage or corrosion, check the battery cables at "BOTH" ends for loose, corroded, or broken connectors, "INSIDE" and outside the cable harness, perform connector wiggle test and check cables with an ohmmeter if necessary.
4. Bank angle sensor tripped and ignition/light key switch not cycled to the "OFF" position and then back to the "ON" position.
5. Faulty starter button/switch.
6. Faulty kickstand or clutch pull in switch/sensor.
7. Security alarm needs a reset.
8. Starter control circuit, relay, or solenoid faulty.
9. Main fuse or circuit breaker may be blown or faulty.
10. Electric starter shaft pinion gear is not engaging or over-running starter clutch slipping.
For more information about your issue and valuable "FREE" downloads that you will need please click on the links below. Good luck and have nice a day.
gv250 starting problems
http://www.alternativecruisers.com/index.php?action=printpage;topic=10801.0
http://meiguohosting.com/How-to-fix-start-problem-for-your-2011-Hyosung-GV250-Aquila-EFI
2008 Hyosung GV250 Aquila Starting Problem
http://files.hyosungmotorsusa.com/GT125_250_Service_Manual.pdf

May 11, 2016 | Hyosung GV 250 Aquila Motorcycles

1 Answer

Hyosung 650 aquila starter solonoid


For Every starter motor there is a Relay check the relay near the battery for he starter motor/ Change

Apr 27, 2014 | Hyosung GV 650 Aquila Motorcycles

1 Answer

Bonjour, je ne parle pas l'anglais et je m'en excuse. Je possède une aquila GV 125 cc de 2002 et depuis quelques jours mon compte tour et ma jauge d'essence ne fonctionnent plus. Auriez...


Hi, Jmcarlier if some or all of your instrument cluster goes dark/blank immediately upon startup or a few minutes later riding down the road the usual suspects are:
1. Blown instrument fuse.
2. A bad ground in the instrument circuit.
3. Faulty wiring before or after the fuse.
4. Faulty wiring or connector between the fuse and the instrument cluster.
For more information about your issue and valuable "FREE" downloads that you will need please click on the blue links below. Good luck and have a wonderful day.
https://www.perthstreetbikes.com/forum/showthread.php?t=134911
HYOSUNG COMET 125 Service Manual
HYOSUNG GV125 PARTS CATALOGUE Parts Catalog
http://www.hyosung-motos.ch/fileadmin/medien/pdf/handbuecher/GV125.pdf
Hyosung GV 125 Aquila 2005

May 28, 2017 | 2002 Hyosung GV 125 Aquila

1 Answer

Hi i just got my self a 125 hyosung aquila the battery went flat on it i left the key on, i charged the battery and put it in again she wont turn for me what can i do?


You need to check the voltage of the battery after charging it. It may have become so discharged from leaving the ignition on that it will not recover and will have to be replaced.

Feb 01, 2010 | 2003 Hyosung GV 125 Aquila

Not finding what you are looking for?
2003 Hyosung GV 125 Aquila Logo

Related Topics:

223 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hyosung Experts

Arnie Burke
Arnie Burke

Level 3 Expert

4536 Answers

yadayada
yadayada

Level 3 Expert

77499 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22306 Answers

Are you a Hyosung Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...