Question about 1999 Aprilia RS 125 Extrema

1 Answer

Just run in after complete rebuild and new power vaulve.now there is flames comeing out of the exhaust.and it seems to loose power after shutting off for a corner.also just put new plug in.

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Champion:

    An expert who has answered 200 questions.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

  • Expert
  • 224 Answers

The flames from the exhaust means your fuel system is rich. If it's losing power and bogging down in a turn (leaned over) or in a wheelie makes me think your float level height is to high. Could also be your mixture screw just needs to be adjusted.

Posted on Dec 10, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My York furnace sometimes doesn't completely ignite


A noisy inducer probably is headed for replacement.

The igniter can produce a healthy glow and still be defective. Mine had to be replaced with a new, improved one.

The thermocouple could be defective even though it seems to open the gas valve when it should.

The heat sensor in the bonnet could be defective. That controls main blower operation.

The heat exchanger could be cracked.

Jan 10, 2014 | Heating & Cooling

1 Answer

I have a Kenmore Dryer Mod#110 62722101. It will run about 10 minutes and shut off, after a cool down period it will restart but only run about 10 mins. Heats, fine, tumbles fine. A few days before this...


If it runs after a cool down period, then the high temperature limit is part of the cause. What is causing the high temperature limit to overheat is next.
Strong stream of air should be felt coming out the exhaust, make sure this exhaust air works or the burner part will overheat and cut out the flame/burner on hight temp safety.
With good exhaust air varified, the drying air operating temperature sensor needs to be checked, this cuts power to the burner. The sensor must open electricaly when satisified on temperature and should be properly mounted for proper sensing of temperature.
Bottom line: Check the hot air and its control

Jun 04, 2017 | Dryers

1 Answer

I have a Johnson air ease 90 plus.I turn the thermostat up and exhaust blower comes on igniter comes on and i can hear the natural gas release for a second or two then igniter shuts off along with gas. Fan...


If the burners come on for a few seconds and shut off check the flame sensor near the burners and clean it with steel wool, usually this will fix the problem. The flame sensor is a metal rod that is immersed in the burner flame on the opposite side of the igniter. robhvac47_7.jpg

Jan 17, 2011 | Heating & Cooling

1 Answer

Buner does not shut completly off. flame lingers near orifice. how determine if its the gas valve or temp control?


The thermostat is a snap action. It is either completely on or completely off. The combination valve may be letting a little extra gas pass by the main valve. Unless it is a significient amount of flame or it continues for more than a minute or two, just keep an eye on it. It is not unusual to see a tiny flame at the orifice, but it usually dies out in less than a minute or so. You can get a rebuild kit for the gas valve. The complete valve is around $150.00. You will need to get the model number and the serial number of the fryer, to buy either the valve or the rebuild kit. If you are very confident in your abilities to do a gas valve rebuild it should take a couple of hours to remove the valve by removing the main gas line, then the manifold that runs to the burners. You will also have to remove the wires that run to the high limit switch and thermostats. Be sure to mark the wires as you remove them. The gaskets are very fragile. As you take the valve apart lay everything in order so that you may retrace your steps in putting it back together. There is an exploded view of the valve in the rebuild kit. You MUST check for gas leaks before lighting the fryer after you have rebuilt the valve. With the gas pressure on, but the pilot not lit, spray the entire valve with liquid leak detector, available at the same place you get the rebuild kit. You can also use dishwashing liquid, but either way look for bubbles at all the gasket locations as well as the gas pipes and manifold that you removed. If you see ANY bubbles, don't light the pilot. Start over with new gaskets. Hope this helps

Oct 15, 2010 | Pitco Frialator 35CS Deep Fryer

1 Answer

Onan generator not running


recheck, reclean,and rebuild carb possible had moisture in fuel and carb --white smoke--but sounds like float and carb still gummed up

Feb 15, 2010 | Watts Onan Portable Generator - 4000 ,...

2 Answers

The gas dryer is not getting hot enough to dry clothes have to run it double the time to get clothes dry-exhaust not blocked-igniter is working-there is a flame-checked dryer heat setting manual knob with...


You might want to replace the thermacouplar. Sometimes when they are going out , all will appear to be alright but as you stated it takes a long time for the flame to come back on. This sounds to me like the thermacouplar is going out.

Dec 08, 2009 | Amana ALG331RAW Gas Dryer

3 Answers

1997 volvo850gtl extreme smoking from exhaust


black smoke ( burning too much gas)
blue smoke (burning oil)
white smoke ( burning coolant)
hope this helps

Jun 15, 2009 | 1999 Oldsmobile Bravada

1 Answer

Poulan pro 25cc will start but not continue to run.


Is it difficult to pull? If so it could be the exhaust flame arrester has fouled with carbon. Over time it will become completely clogged and will not allow the engine to come up to speed or even start. Remove the exhaust and you will find the screen on the inlet side of the exhaust.

Apr 26, 2009 | Poulan/Weed Eater No. Bvm200le 711482 24cc...

1 Answer

Heater will not run more than 1 cycle.


Check your thermocouple. You should never leave it on pilot to run. The Thermocouple detects flame and it doesnt seem like it is detecing the flame. You can go to a local appliace shop and pick up your new thermocouple

Feb 19, 2009 | Williams 3003622 Ceramic Wall Mounted...

Not finding what you are looking for?
1999 Aprilia RS 125 Extrema Logo

Related Topics:

158 people viewed this question

Ask a Question

Usually answered in minutes!

Top Aprilia Experts

Marvin
Marvin

Level 3 Expert

83096 Answers

Arnie Burke
Arnie Burke

Level 3 Expert

5374 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Are you an Aprilia Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...