Cleaned gas and changed fuel filter. Mower only runs with full choke on. Stalls without full choke.
There are a number of things that can cause this, depending on the engine fitted. Assuming a Briggs & Stratton V-twin...
Check that the carb solenoid under the float bowl is connected, has battery voltage when the ignition switch is at 'RUN', and is functional.
As a quick check, with the engne OFF, turn key to 'RUN' there should be an audiable 'click' from the carb if the solenoid is working.
After that, check that the fuel pump is delivering fuel (disconnect output, and crank engine). SHould be a good flow.
377 views