The OH Light keeps coming on although the temperature never exceeded 100 degrees.

The OH Light comes on. I know that means Over Heating but, our Hot Tub has never gotten over 104 degrees. In Fact when I noticed the OH light was on, the temp was only 100 degrees. I cut it off and let the tub sit for quite awhile turned it back on and the temperature was about 88 degrees. The OH Light was flashing so I pressed the jets and they come on and the OH Light disappeared. I waited about 10 min and the OH Light was on again. I repeated this procedure several time but the OH Light keeps coming back on? Have any answers and is this something I can fix on my on?

1 Answer

David Spradling

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Renaissance:

An user who is expert in 3 categories / brands.

  • Master 1,448 Answers
  • Posted on Oct 18, 2014
David Spradling
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Renaissance:

An user who is expert in 3 categories / brands.

Joined: Jan 11, 2014
Answers
1448
Questions
2
Helped
518489
Points
1901

Check your recirculation pump it sounds like it isnt working or plugged filters

5 Related Answers

Samuel Phillips

  • 78 Answers
  • Posted on Apr 22, 2009

SOURCE: QCA Opal hot tub display reading OH.

The tub experienced an overheat situation. This may be due to leaving the t stat turned all the way up and not monitoring or the hi-limit sensor is defective. The hi-limit sensor will shut down the heating cicuit if temp gets above 105 D optimally.the fact that the heater light is on is a good sign that things are working at this point.Whether or not a suitable temp(100-103 D) will be arrived at is to be seen. If spa heat kicks off before set temp is reached then replace hi-limit sensor.

Ad

Anonymous

  • 37 Answers
  • Posted on Dec 05, 2009

SOURCE: savannah spas

probably a dirty filter!! take it out turn tub off to reset turn back on with filter out and c if nthis solves problem if so replace filter.

Coastsider

Charles East

  • 331 Answers
  • Posted on Apr 14, 2010

SOURCE: mystic hot tub doesn't stay hot enough

Is your spa wired for 110Volt or 220V?

Ian  Hot Tub

hot tub plus

  • 77 Answers
  • Posted on Apr 17, 2010

SOURCE: Intermittent jet problem on Spa form hot tub

Hmm, that's an odd one. It could be either a fault with the PCB or the pump.

The first thing to check is the voltage to the twin speed pump. If that's ok the motor is probably the cause of the fault.

As always, with anything electrical you need to be very careful with what you're doing and if you're unsure seek professional help.

Regards,
Ian.
http://hottub.synthasite.com

Anonymous

  • 310 Answers
  • Posted on Oct 28, 2010

SOURCE: my hot tub control panel keeps showing OH and the

It sounds like your circulation pump is not keeping up with the heater. Check for debris in the pump impeller. If this is 24 hour circulation pump, it is probably failing. New units are about $200 US

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Why the hot water temperature couldn't reach the set temperature (130 degree) in Amtrol WHS80Z indirect water heater?

I have a couple of thoughts. You may have air in the boiler water circuit at the loop that feeds the tank. You'll have to find the vent in the loop to get it out. Second, the automatic valve that opens for hot water may not be opening fully. Have you felt both the boiler water lines that go in and out of the tank? If the water going in is hot and the line out is very cold you have very little boiler water going through the loop. Make sure the isolation valves on the loop are open. Is your boiler full of water? If the boiler loop lines are hot going in and coming out, the tank is full of rust or debris and no water can get to the fins on the internal tubing to pick up heat. If that's the case there is no repair and its time to get a new tank. Hope this helps good luck.
0helpful
1answer

Adjust thermostat

A thermostat only cuts the heating off when the temperature it is set to is reached while the heating is on. If the heating is set to off then the thermostat will do nothing.
Generally you want to think about when you want your heating to come one and off by using the timer and then the thermostat is just used to ensure that you don't waste energy by exceeding the maximum comfortable temperature.

Hope this helps a little.
Nov 22, 2013 • Ovens
1helpful
2answers

My ac unit will not go below 77 degrees. It quit working about 1.5 weeks ago, and I had a service technican come and look at it. He replaced the capacitor and the unit started back up and would cool to...

Hi, It sounds to me like you have covered all of the basis. The evaporator coil should be clean if you keep your filter clean and the condensation is showing that it is cooling properly. Normally, when the temperature increases outside, you will loose as much as 35% of your units efficency as it it working very hard. 77 degrees is very good temperature if the outdoor temperature is in the triple digits or a little less. It may be that your thermostat is off just a little also. If you clean your coils and keep it up like he said, that is great! I wish more people would do this. You should have a 18 to 25 degree temperature difference between the supply air from you vents and the return air at your filter. Example, if your supply air is 56 degrees, and the return air is 76 degrees, a 20 degree difference or TD, that is excellent. You can check this with a thermometer. I live in Northern Ca and it gets up to 116 degrees here in Redding!! We are lucky to have it 80 degrees in our home, no kidding!!. If you are unhappy, call this tech about it and see what he says. Your indoor coil is fine if you have no ice and I know you keep your filter clean. If you lost a capacitor again, you would have no cooling. Like I say, keep a eye on it, it could be the stat not accurate. Check the supply at the vents and filter to see what you have. If its lower then 18 degrees or higher then 25, you have a problem. If you are in the triple digits, this will cause this. I wish you the best and keep up the good work on that unit! That' great! Please keep me posted and please be kind when rating me as I know you will. Let me know the out come.
Sincerely,
Shastalaker7
A/C, Heating, & Refrigeration Contractor


2helpful
2answers

The AC doesn´t work when outside temp goes 100 degrees and above

Try using a garden hose to wash down the condensor coil (the coil that is exposed to the outside air).
During the cooler times when it seems to be working, check the temperature difference of the air coming out against the temperature of the air coming in (room temperature air). The temperature should be approximately 16 to 22degF difference. If you are not getting at least 16degF air, you most likely need to have your unit serviced to see if professionial cleaning or a recharge is needed. If you are getting the temperature difference but not getting the amount of cooling you need during hot weather, it could be a capacity problem. You can perform a quick test by using the calculator on this site:
http://www.goodhousekeeping.com/home/air-conditioner-calculator.

I hope you find this information helpful. Good Luck! :-)
0helpful
1answer

Spa / hot tub does not heat

Your temperature control is way out of calibration or, it's wired wrong. Remove it and check it in a glass of water. Use an ohm meter across the heater wires. As you add hot wwater, the heater contacts should open.
0helpful
1answer

Humidity factor up to 92 degrees ,although it keeps the temperature down to 69 degrees

HMMM, I am not quite sure exactly what your setup is. My first question is how are you reading humidity and is it accurate. Second if you are maintain 69 degrees, is it hot and humid outside? If your unit is low on charge, the evaporator (indoor) coil will maintain a warmer temp reducing its ability to reduce humidity but if it is hot outside, you would not be keeping at 69 degrees. If this is a new system my best guess is that the system is over sized. I know a lot of people want a big AC unit to cool down quick but if the unit comes on, runs for 2 minutes and shuts off, It is not running long enough to remove any humidity from the air,thus proper sizing is extremely important. Let me know exactly what your situation is and lets see if we can get it fixed.
seth
1helpful
2answers

My Jeep Cherokee 95 Radiator temperature is always hot

100 degrees f? That is way too cold Either you have the wrong thermostat or it is wide open. 180 degrees is nominal and give you the best performance.. With AC on, expect 190 to 200 degrees. We are talking farhrnheit and not ccelsius, correct?
0helpful
1answer

My rf367 range gets so hot during the self cleaning cycle that the top of the range is to hot to touch and the fan on my otr microwave comes on.

Normal operation. If in doubt place a high temp theromoter on range top to see if it exceeds 600-900 degrees
The basic idea is "burn baby, burn!" Self-cleaning ovens use an approximately 900 degrees Fahrenheit (482 degrees Celsius) temperature cycle to burn off spills leftover from baking, without the use of any chemicals. A self-cleaning oven is designed with a mechanical interlock (patented in 1982) to keep the oven door locked and closed during and soon after the high-temperature cleaning cycle, which can be approximately three hours. The door stays locked to prevent burn injuries. You can open the oven door after the oven cools to approximately 600 F (315 C).
Not finding what you are looking for?

327 views

Ask a Question

Usually answered in minutes!

Top Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29492 Answers

David Spradling
David Spradling

Level 3 Expert

13520 Answers

Are you a Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...