Question about Motorcycles

1 Answer

I have a Honda EB 7000I generator. It runs for 7-10 seconds then stalls. When it stalls the red LED overload light comes on. I just put a brand new Inverter in it. Since it sat awhile with a bad inverter in it, I also changed the plug, drained and cleaned carb bowl/ get/ need and seat, checked for water in the fuel. Turned eco throttle on and off still does the same thing. Only gets to around 1,445 RPM,s. Does not spit or sputter...

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 364 Answers

As silly as this sounds, Harbor freight toold generators by "Predator" will shut down if the generator is not on level ground, and the oil level is not at the desired level, crazy but there is an inbuilt oil level sensor. maybe this might be the answer. hope iy helps, good luck.

Posted on Oct 20, 2013

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 126 Answers

SOURCE: engine runs, but it will not rev up past 2000-3000 rpms,

are you turning the choke off after its warmed up? most will not run with the choke on and warmed up.

also try running it with the gas cap open to see if you have a vent issue in your tank. if air can't get in, then gas can't flow.

if not a choke or vent issue, then try this. turn the petcock off and then disconnect the fuel lines one at a time going into the carb. start with carb fuel line #1 disconnected (and the rest connected) and in a coffee can, turn petcock on and ignition too. fuel pump should come on momentarily and inject some fuel. see how the quantity looks. reconnect the line to carb #1 and repeat for carbs #2 - #4. your looking for a decrease in fuel to a couple of cylinders.

if all looks fine, i would then focus on the carb floats & jets. have the carbs been off for a good cleaning lately? modern fuel breaks down quickly and could cause a gumming condition in the carbs. spraying the sea foam or carb cleaner into the carbs is bypassing the everything in the carb bowl (but it means the spark plugs are ok) so there could be an obstruction. i would look there first.

if uncomfortable removing the bank of carbs, you can try a quick fix first. with the petcock closed, open the drain screws of each carb and let the gas drain out. go and buy some yamaha carb cleaner (liquid in a black bottle) at a yamaha motorcycle dealer. mix it in a separate container with gas as recommended. close the drain screws on each carb. pour the mixture into each fuel line feeding the carb and let it sit overnight. DO NOT POUR THIS MIXTURE INTO YOUR TANK. its not a fuel additive, but a cleaner that will not harm orings or gaskets, but it will not ignite with a spark plug. open the drain screws the next morning and let the mixture pour out. reconnect the fuel lines to the carbs and test drive it.

if that didn't work, then removing the carbs for a good cleaning is my next step. good luck.

Posted on Jan 28, 2009

SOURCE: My FZR 600 is acting up and backfires

I have had several bikes in my time. and keeping the carbs syncranized is very important. Did you put aftermarket pipes on it? try rejeting the carbs up 2+mm that may help the fuel air ratio?

Posted on Feb 01, 2009

  • 9 Answers

SOURCE: how to drain fuel from carb bowl?????

there should be a screw or a larg looking bolt on the bottom of the float bowl (carb) remove it and it will drain use a rag to catch it and drain your tank add fresh gas (if it dose'nt run right you may have to clean the carb)

Posted on Apr 04, 2009

  • 375 Answers

SOURCE: I need tuning specs for my 1982 suzuki gs 750.

You need to fix the fueling first - without fuel it won't run!
Your other problem sounds like an air leak - either the manifold or the carb. Check by spraying WD-40 or CRC at the manifold and carb join while the bike is running - if the revs change (either up or down) you have a leak.

Posted on Jun 29, 2009

ollie reece
  • 1167 Answers

SOURCE: My 99' gsxr 600 won't go past idle.

hi mate im prety sure these bikes have injectors rather than a carb

Posted on Aug 25, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Honda eb 7000 inverter generator won't stay running. It runs for 12 seconds and stops. I tried disconnecting the oil sensor but no luck.


it appears to be insufficient fuel flow to the carby
check for blockages in the tap , lines , tank filter, needle and seat area

Aug 03, 2016 | Honda Electrical Supplies

2 Answers

What can you advice me to do? i have a UPS SURTD5000XLI, indicating a red Led light, but when i remove it from the AC power source, the Red Led also remove & when i flog it again to the AC Source it...


Is red light on for overload or for battery?
If on overload, try reducing the load on the UPS. If red light on overload persists buy a new UPS (overload fault hard to repair).

Red light on battery - replace the batteries.

Red light on boost or buck, may mean that the nominal voltage of ups and the limits need to be changed/corrected.

Jun 23, 2014 | APC Smart-UPS RT 5000VA (SURTD5000XLI) UPS...

2 Answers

Generator will not stay running


The toggle switch automatically resets all faults when it is turned to the off position. I would turn the toggle switch off, turn off the breaker on the generator and then turn off all the loads in the house except a few lights. Turn the generator breaker back on, then turn the toggle switch back to automatic. If it starts and stays running, you were overloading the generator. Turn on other loads slowly and keep track of what is on so you don't overload it again. If it still does not stay on, you may have a problem with the panel. Let me know what happens.

Nov 20, 2013 | Briggs & Stratton 15,000 Watt Home Standby...

1 Answer

Generac generator on auto runs weekly. light green previuosly green. now red. what causes this??


Hi and welcome to FixYa I am Kelly. Your red LED is telling you that it was 1. overloaded. 2. has low voltage 3. overheated or 4. short in the powered circuit.

OVERLOAD LED (red): Lights up if the generator experiences
a load greater than the rated output, low voltage, overheats or
the powered circuit experiences a short. The output is stopped
even though the engine keeps running.

I do not know which of the 4 conditions caused your red light. If you have the read light with no load I would suspect low voltage from the generator / inverter. If it overheated you will also get the Red LED with no load.

Thanks for choosing FixYa.

Kelly

Aug 30, 2010 | Kitchen Ranges

1 Answer

My kipor KGE 1000Ti starts fine but after several minutes stops generating and the red overload light comes on, with the demand for power left connected and the generator still running electrical...


You may be UNDERLOADING the generator and it may be unstable with such a light load... see if it might behave running a heavier load... put a 100 watt light on it as a test,

Jul 25, 2010 | Electrical Supplies

1 Answer

I have a Honda 7000 EM inverter generator. When it starts after a few seconds the overload light comes on and it shuts down. What is the problem?


ARE SURE ITS THE OVERLOAD LIGHT AND NOT THE NOIL ALERT? IF ITS THE OIL ALERT ITS CAUSE YOUR LOW ON OIL OR THE SENSOR INSIDE THE GENERATER IS BAD?

Sep 09, 2009 | Honda Electrical Supplies

1 Answer

Honda eu 6500 gen overload indicator light will not shut off


Check the Ground Fault Indicator circuit breaker for triping, and look for the high limit on generator. Reset the main breaker by triping it full right and then back. Vitally

May 22, 2009 | Honda 6370C - Parallel Power Kit For ...

Not finding what you are looking for?
Motorcycles Logo

Related Topics:

150 people viewed this question

Ask a Question

Usually answered in minutes!