Question about 2004 Yamaha Road Star Silverado

1 Answer

30 amp main fuse blows when the key is turned on.

First started while riding on freeway, motor just quit (blown fuse) replaced fuse, moved wiring harness around, started and ran for a while. 'But now the fuse blows as soon as the key is turned on. I can't find any wires that are shorted out. Could it be the selinoid of voltage regulator. Sometimes the fuse blows while trying to start engine. Engine has 10.5 to 1 high compression pistons with electric compression release that does not seem to be opening up enough. The battery seems plenty hot enough. Sometimes when cranking the starter, I can smell what seems to be some wires getting hot, but cannot locate the hot spot. All wiring looks good, but can't see all places where the wiring harness runs between the frame and motor. Need help in knowing where to look for a short, ground or maybe a falter ignition part.

Posted by on

  • kwd27 May 11, 2010

    Where you carrying anything (anyone) when this happened?



1 Answer

  • Level 1:

    An expert who has achieved level 1.


    An expert that hasĀ over 10 points.


    An expert whose answer gotĀ voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 10 Answers

Can be "nasty problem, for it can mean DEATH, if as you attempt traffic manouvre & it blows !-(As safety precaution , & this TIP would be useful to most all Bikers>Call to friendly POLARIS ATV Dealer & ask for Automatic Re Settable 20 AMP PROTECTOR ( tHIS FITS THE 500 sPORTSMAN A T V & as far back as the 350L 2 Cycle Firebreathing A T V ()Standard Equipment )-Wire that in from POSITIVE Supply on to your loom, & attch its earth ( Negative cable to NEGATIVE > - on Your Battery!--That done, procede to your RecRegulator Unit &Examine Likely "Melting of Delrin (Nyloc, White looking plastic connector plug to terminals of Rectifier/Regulator , Test Output from Alternator., Ensure ALL Eaths have been attended properly, by Unscrewing, & Shining through the Paintwork Refit, tighten & Apply Silicone Sealant ( So that when You "Power Clean" the Motorcycle You wont be "Degrading the EARTHS again!--Now Ride!--If the Loom Loom, near steering head happens to "Short out" The POLARIS Re Settable Fuse Link & Sealed in waterproof covering, will Re Set & then You get chance to further investigate at Your workshop!!Arm yourself with Voltohmyst , or Multimeter OOR mini pointer that can sense Current Flowing, check out ALL Swithes ( Disconnect rear brake light switch & front one by way of unplugging supply leads ( Just possible that You have intermittant short in one of them!--Did You happen to note IF You were turning slightly to Left or Right when Fuse Blew?--Well, look then for "Stress areas for wiring looms, as at Steering Head Stem region, Open the Sheath with Razor Blade & attempt to pull wires apart slightly , then EXAMINE RFOR>bare leads !---With Multimeter You could slowly "ISOLATE" components & IF You had reference to WIRING CHART You then could Painstakingly TRACE EACK LEAD & ENSURE it has no "LEAKAGE "--Best Of Luck & "StayUpright" -Des.

Posted on Jan 17, 2009


1 Suggested Answer

  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017


Add Your Answer

Uploading: 0%


Complete. Click "Add" to insert your video. Add



Related Questions:

1 Answer

My york heat and air unit with emergency heat is blowing 30 amp fuses and sparking at the fuses and contactor when turn main breaker back on. I have replaced contactor, transformer and the compacitor on...

You either have something wired wrong or you have a direct short in the system. Are you starting the A/C or the furnace? If it's the A/C, it could be a shorted compressor, capacitor, fan motor or it's wired wrong.

Oct 30, 2013 | Heating & Cooling

1 Answer

1997 Harley Ultra Classic 30 amp main breaker pops while riding. Also blows 10 radio power fuse

Hi Anonymous, you have a hard/dead short that should be easy to find generally they are the easiest. Time to get out your test light and start tracking the wire from the power side of the switch, circuit breaker or the blown fuse receiver, when the test light quits lighting you are very close to your short. For a free wiring diagram please visit the website below and good luck.
Harley Davidson Wiring Diagrams and Schematics

Jul 19, 2012 | Harley Davidson FLHTCUI Electra Glide...

1 Answer

1997 Harley Ultra Classic blows 10 amp radio power fuse and 30 amp main bike breaker

Hi Anonymous, sounds like you have a hard short between the battery, ignition switch and the radio. For a free wiring diagram please visit the website below:
Harley Davidson Wiring Diagrams and Schematics
Good luck

Jul 19, 2012 | Harley Davidson FLHT - FLHTI Electra Glide...

1 Answer

Why does my mower keep blowing the 20 amp fuse

could be the safety switch for the pedal

Apr 23, 2012 | Husqvarna Garden

1 Answer

20 amp fuse blows when key turned to on.

unplug the wires on the side of the engine and plug one in at a time

Apr 21, 2012 | Garden

1 Answer

Can a bad voltage regulator cause the main 30 amp fuse to blow?

Usually a bad regulator will only cause problems with charging...
Sounds like you've got a short somewhere in the wiring...I'd start by checking the ignition switch wiring and the connections going into the fuse box.

Mar 19, 2012 | kawasaki VN 1500 Vulcan Classic...

1 Answer

Main 30 amp fuse keeps blowing when i plug the 4 wire fuse top back on after replacing 30 amp fuse. any suggestions

Hi, Anonymous before diagnosing your blown fuse issue, check the bottom of your seat, if it's metal and comes in close proximity to the positive battery post you need to take the necessary steps to ensure there is no contact (electrical tape, thick rubber insulation, hammer a dent in the seat bottom etc.) You are going to need a wiring diagram from your service manual, a test light, an ohmmeter and plenty of extra fuses.
If you turn on your ignition switch and immediately blow a fuse you have a hard/dead short and is usually easy to find. With a test light connected to the hot side of the blown fuse holder start stabbing the wire/s that leads away from the fuse holder and towards the ignition switch, you test light will illuminate validating the short. When the test light fails to illuminate you have passed the short and need to back up until the test light illuminates, then look in the immediate area for the short.
If you driving down the road for 30 minutes or 15 miles and blow a fuse you have soft/flying short and may take some time and patience to find.
If the main fuse/circuit breaker constantly blows/trips while riding you probably have a faulty battery terminal connection. Check battery terminals for damage or corrosion, check battery cables at "BOTH" ends for loose, corroded, or broken connectors, "INSIDE" and outside the cable harness, perform connector wiggle test and check cables with an ohmmeter if necessary. Any other fuses that constantly keep blowing while riding are usually caused by a loose or corroded ground wire in the circuit, which means you have to check, inspect, test each and everyone with an ohm meter set on a low ohm scale 100 ohms or less . Simply touch one lead to the ground source and the other lead to the battery negative terminal, a reading of zero indicates a clean solid ground. Any number reading or infinity indicates a poor ground and needs to be repaired. Poor or weak grounds require excessive additional amperage to complete the circuit which in turn blows the small amperage fuse.
For more information about your issue and valuable "FREE" downloads that you will need for viewing or printing please click on the blue links below. Good luck and have a wonderful day.
keep blowing the 30 amp fuse
main fuse keeps blowing
Honda Shadow VT1100 Owner Manual
Honda shadow vt1100 Owners Workshop Manual

Jul 14, 2017 | 2003 Honda VT 1100 C Shadow Spirit

2 Answers

LTX1000 42" 18HP Kohler - Blowing fuse after 2-4 min mowing.

sounds as though you are on the right track
but be sure to check the wiring directly from the electric clutch on the front of the motor back to the switch
a wire could be pinched in the frame and shorting out intermittingly
look around and find those wires and move them around and look for chaffing and tightness
and what you could also do is to unhook the clutch at the connection to it at the front of the motor and engage switch and ride around and see if fuse blows and if not you may have an electric clutch issue

Jun 07, 2009 | Craftsman 17.5 hp 42 in. Deck Lawn Tractor...

1 Answer

Fuse blows on wiper when i start my 1999 dodge ram pickup

Hi my name is Allen!

When the fuse for the wipers keeps blowing, that means either the motor has a dead short within it and must be replaced, or the wiring going to the motor is damaged and shorting out on the vehicle body somewhere and must be repaired.

Here is how you check it; replace the blown fuse, unplug the connector from the wiper motor, then turn the key on if the fuse does not blow then you need to check the wiring to the motor if the wiring is not damaged anywhere replace the wiper motor.

For further assistance contact me at FixYa!

Dec 24, 2008 | 1997 Dodge Dakota

Not finding what you are looking for?
2004 Yamaha Road Star Silverado Logo

555 people viewed this question