2002 Dodge Caravan Logo

Related Topics:

Posted on Feb 17, 2011
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Blower fan does not work? - 2002 Dodge Caravan

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

  • Expert 266 Answers
  • Posted on Feb 17, 2011
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

Joined: Feb 11, 2011
Answers
266
Questions
1
Helped
71986
Points
836

Wiggle the connection at the blower mtr .make sure all the fuses are good even take a hammer and lightly tap blower mtr...If that doesnt help and power is present at blower mtr connection then blower mtr needs replaced

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

Gmc 2500 truck work blower does not work at all

Check your fuses for the blower motor. If they are ok, it is probably the blower fan resistor which is located on or next to the blower fan assembly under the passenger side dash in the footwell. if resistor is bad, there will be no fan speeds. make sure you are getting power to fan motor, if power but fan does not work then its the fan. check fuses and fan resistor first. good-day !
5helpful
2answers

01 grand.prix ac fan switch only works on high. has a duel temp controller when you turn fan off the only way fan comes back on is to move the temp controller levers

Hi!!
When the Blower Motor Resistor (controls blower speeds) goes bad, the blower motor works only on HIGH SPEED. REPLACE IT.
BLOWER MOTOR RESISTOR Removal & Installation
  • Disconnect negative battery cable.
  • Remove right lower instrument panel insulator panel.
  • Disconnect blower resistor connector located behind right side of dash.
  • Remove blower resistor screws and blower resistor.
To install, reverse removal procedure
Good Luck!! A HELPFUL - 4 THUMBS - rating for this solution would be greatly appreciated. Thank you for using FixYa!!
2helpful
2answers

Heater blower stopped working?

Hello,
You may want to try your fan on all speeds. If it will work on high, you have a bad resistor for the fan motor. ( high speed doesn't go through the resistor ).
If it doesn't work on any speed, I would check the following;
1. Make sure the fuse isn't blown for the fan blower motor.
2. Check, or have checked the wires between the fan control switch and the fan blower motor.
3. Have the fan control switch checked.
4. Have the fan blower motor checked.

I hope this helps you.
1helpful
1answer

Heater/defrost/ac does not blow in my 2006 tacoma. worked this morning, parked at work, came out half hour later and would not work.

what has most likely happened is that a fuse has blown that is in your blower fan circuit. Check your owners manual, and see if there is a fuse to that system, if there is, check and see if it is blown. If it isn't, then the problem could either be your blower fan itself, or your blower motor resistor. Generally, when the blower fan goes bad, no speeds of the fan work. When the Blower motor resistor goes bad, usually only 1 speed of the fan works. Try the first suggestion i gave, and it everything checks out in the fuse box, then try all of your fan speeds. If one works, you need a blower motor resistor, if none work, then it is most likely your fan. Let me know how it goes and i'll do my best to assist you further. good luck.
3helpful
2answers

2005 Chevrolet Silverado - Fan not coming on. When I turn the heater/ac blower fan on, fan does not work. Prior to completely going out, fan would quit working intermittently. Is this a fuse problem? ...

Chk for power at the blower motor electrical connector. If no voltage, check the blower motor resistor, its within the blower motor vent (this controls power to the blower motor). Also, in theses vehicles water may have damaged the blower motor itself. Inspect the blower motor for proper function.
1helpful
1answer

My fan stopped today. it was working fine and then gone. the rear works fine and I checked the fuses and they all seem fine?

Check the fan relay(or fan module near the blower)or the fan switch itself,or the blower motor is bad,bump the blower motor while the switch,and key are on,if the blower starts working,it is bad.
0helpful
1answer

Saturn 2000 LS2 Blower Fan Problem

You blower fan obviously works. Try replacing the fan speed switch.
4helpful
2answers

Blower fan not working correctly

It is the blower motor resistor and is located under the glovebox behind the blower motor.
Not finding what you are looking for?

177 views

Ask a Question

Usually answered in minutes!

Top Dodge Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Are you a Dodge Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...