If the fuses are all good change the blower motor-

  • Disconnect the negative battery cable.
  • Disconnect the blower motor lead connector from the wiring harness connector.
  • Remove the blower motor cooling tube from the blower motor.
  • Remove the four retaining screws.
  • Turn the motor and the wheel assembly slightly to the right so that the bottom edge of the mounting plate follows the contour of the wheel well splash panel.
  • Lift up on the blower and remove it from the blower housing.
  • Installation the new blower motor by reversing the removal steps.
  • Connect the negative battery cable.
  • Posted on Jan 11, 2011

    Ad

    1 Suggested Answer

    6ya6ya
    • 2 Answers

    SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

    Hi,
    a 6ya expert can help you resolve that issue over the phone in a minute or two.
    Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
    New users get 2 Free calls (no credit card required) and instant help on almost anything you can think of (from cars to computers, appliances, handyman, and even pets).
    click here to download the app (for users in the US for now) and get all the help you need.
    Goodluck!

    Posted on Jan 02, 2017

    Ad

    Add Your Answer

    Uploading: 0%

    my-video-file.mp4

    Complete. Click "Add" to insert your video. Add

    ×

    Loading...
    Loading...

    Related Questions:

    1 Answer

    Heater fan runs when heater is off.06 ford expoler


    Automatic or manual climate control ?
    • The blower motor does not operate correctly - manual climate control
    • Circuitry short
    • A/C blower motor resistor
    • A/C blower motor switch
    • Blower motor high speed relay
    • Go To Pinpoint Test O .

    • The blower motor does not operate correctly - EATC
    • Circuitry short/open
    • A/C blower motor speed control
    • EATC module
    • Go To Pinpoint Test Q .

    Pinpoint Test Q: The Blower Motor Does Not Operate Correctly - EATC
    Normal Operation Under normal operation, the blower motor control module receives a 1-2 volt signal from the EATC module through circuit CH218 (GN/VT) to determine the desired blower motor speed. The EATC module receives a feedback voltage from the blower motor control module through circuit VH219 (GY) to determine actual blower motor speed. When the highest blower motor setting is selected, the EATC module sends 12 volts to the blower control module through circuit CH217 (BN).
      Possible Causes
    • An open, short to voltage, ground or together in circuits CH218 (GN/VT), VH219 (GY) or circuit CH217 (BN)
    • Blower motor control module
    • EATC module
    • If automatic HVAC system i would suspect Blower motor control module .

    Oct 27, 2016 | 2006 Ford Explorer

    1 Answer

    Location of heater relay on 2003 ford focus.


    There is no relay, according to my info. At the blower motor, green wire is voltage, fuse protected, goes hot with key on. Black wire is ground. The blower speed control switch is part of ground circuit. There are resistors for the lower speeds. Hi speed doesn't use a resistor. If you have good voltage and ground at blower motor and no blower action, suspect the blower motor. Any motor that uses brushes, sometimes you can tap on suspect motor, and it will run intermittently. Sign of bad brushes.
    You may be able to use jumper wires to blower motor connector for voltage and ground, from the battery, just to see if blower motor will run? If it won't run, suspect blower motor. If you use jumpers, use an inline fuse, just in case.

    Oct 15, 2015 | 2003 Ford Focus

    1 Answer

    Heater and airconditioner control on mercery grand marquis


    If the fan will not run on ANY speed in your Grand Marquis, the problem is most likely NOT the control switch.

    Check for power and ground at the blower motor connector. If power and ground is present, replace the blower motor. Otherwise, the problem is most likely a failed blower speed control module (VERY common). The blower motor speed controller is located in the A/C evaporator housing just below the heater hoses.

    Note: It is also common for a bad blower motor to CAUSE the controller to go bad. You MAY have to replace BOTH.

    May 17, 2012 | 2001 Mercury Grand Marquis

    2 Answers

    Power at blower no power at heater control


    Start simple and check the fuse. If you can run the fan on certain speeds but not others, it is most likely the resistor. If the fuse is good but it wont run on any speeds, look at the relay (this component is first in the circuit. If all components turn out to be fine, look lastly to your blower speed control knob.

    Sep 16, 2009 | 1997 Honda Passport

    1 Answer

    1994 lesabre, hi speed a/c motor runs all the


    You need to replace the blower control module. It's about six inches from the blower motor on top of the heater case on the passenger sid of the blower motor.

    Sep 08, 2009 | Buick LeSabre Cars & Trucks

    1 Answer

    Car a/c heat blower stopped no warning


    Check for a blown heater motor supply fuse,
    Check operation of heater motor control relay,
    Check operation of fan speed control switch,
    Check heater motor speed control resistor pack (usually located in the heater ducting - in the air flow),
    Check the heater motor runs if power directly applied to the motor- if not motor may be faulty.

    Aug 26, 2009 | 2003 Dodge Neon

    3 Answers

    Subject: 2004 isuzu rodeo...my ac/heater blower is not working


    The resistors are in circuit only on the lower fan speed settings.
    On the highest speed setting, power is switched directly to the fan motor.
    Check fan power supply fuses,
    Check power is available to the fan when high speed selected.
    If all above OK, apply power directly to the motor to verify fan motor runs- if it doesn't the motor may need replacement/repair.

    Jul 29, 2009 | 2004 Isuzu Rodeo

    1 Answer

    Interior fan won't run to run A/C or heater. I


    If blower only works on high speed I would say blower motor resistor but if it does not work at all I would suspect blower motor. Make sure you are getting power to motor if not it might be blower motor switch.

    Jul 02, 2009 | 1998 Jeep Grand Cherokee

    1 Answer

    I have a 2000 ford E350 van with front and rear air. the front blower motor runs at low speed, The front blower still runs on low even when the knob is set on medium or high. I do not know where the...


    it's either the blower motor switch or blower motor resister. Resistor ?Heater Blower Motor Switch Removal Remove the battery (10655) ; refer to Section 414-01 . Remove the battery tray. Remove the screws. Remove the battery tray. Disconnect the heater blower motor switch resistor connector. Remove the heater blower motor switch resistor (18591). Remove the two screws. Remove the heater blower motor switch resistor. ----------------------------------- Switches Removal Disconnect the battery ground cable. Remove the center trim panel; refer to Section 501-12 . Remove the control assembly. Remove the screws. Remove the control assembly. Remove the A/C-heater function selector switch knob. Disconnect the vacuum harness connector. Disconnect the A/C-heater function selector switch connector. Remove the A/C-heater function selector switch. Remove the screw. Remove the A/C-heater function selector switch. Remove the temperature control switch knob. Disconnect the temperature control switch connector. Remove the temperature control switch. Remove the screw. Remove the temperature control switch. Remove the heater blower motor switch knob. Disconnect the heater blower motor switch connector. Remove the heater blower motor switch (18578). Remove the screw. Remove the heater blower motor switch. ----------------------------

    Mar 31, 2009 | 2007 Ford E-350 Super Duty Length XLT

    Not finding what you are looking for?
    2000 Chrysler Grand Voyager Logo

    376 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Chrysler Experts

    yadayada
    yadayada

    Level 3 Expert

    76649 Answers

    Colin Stickland
    Colin Stickland

    Level 3 Expert

    22219 Answers

    Jeff Turcotte
    Jeff Turcotte

    Level 3 Expert

    8518 Answers

    Are you a Chrysler Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...