Question about 2003 Subaru Outback

1 Answer

A/C ISSUES WITH 03' OUTBACK 3.0

To make a long story short as possible, local certified mech replaced, comp., accumalator, expansion valve and high side line due to a leak, I began having a noise that sounds like the low note of a flute resonate inside of the cab, but only sporadicly. I tracked the noise down to a vibration in the low side line just before it enters the fire wall. I am thinking restriction or malfunction in expansion valve. Maybe too much oil in the system. Any ideas? Also, how much oil should be in the compressor. Subaru says 4oz in the condensing coil, .4oz per hose, .2oz in accumalator, but no spec on compressor.???? HELP!!!!!!!!!!!!!!! JOEL

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

I had this problem and it was because I tried to fill the system myself and I did two things wrong.  One, I had the pressure too high.  Subaru preasors are lower than a lot.  Two, I got air in the line and it was causing this.  I took my Subaru back to a certified mecanic who put my a/c system on a vacuum  for an hour them preasurized it properly and it took the problem away and it works great.

Posted on Jun 26, 2008

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Where is expansion valve located on 2004 mazda 3


That valve is located just in front of the evaporator. You can look for the location that the high side connection uses to go through the firewall and it is either there or just on the other side in the plenum. However, if you replace it, you are looking at a long complicated process that should not be undertaken as a do it yourself project because it requires tools and training that you cannot short cut.

Jul 30, 2014 | 2004 Mazda 3

Tip

Detroit Diesel Fault Codes


Code Description DDEC V Circuit
11 P 187 4 Chain PTO. Short circuit in the power
11 P 187 7 control system PTO wrong answers
12 P 187 3 Chain PTO. Short circuit in the ground
13 P 111 4-level circuit antifreeze. Short circuit in the ground
13 P 111 6 second-level circuit antifreeze. Short circuit in the ground
14 P 52 3 circuit coolant temperature intercooler. Short circuit in the power
14 P 110 3 circuit temperature antifreeze. Short circuit in the power
14 P 175 3 Chain oil temperature. Short circuit in the power
15 P 52 4 circuit coolant temperature intercooler. Short circuit in the ground
15 P 110 4 circuit temperature antifreeze. Short circuit in the ground
15 P 175 4 Chain oil temperature. Short circuit in the ground
16 P 111 3-level circuit antifreeze. Short circuit in the power
16 P 111 5 second circuit level antifreeze. Short circuit in the power
17 P 51 3 Throttle position circuit failed high
17 P 72 3 Bypass position circuit failed high
17 P 3 354 Relative humidity sensor circuit failed high
18 P 51 4 Throttle position circuit failed low
18 P 72 4 Bypass position circuit failed low
18 P 354 4 Relative humidity sensor circuit failed low
21 P 91 3 TPS circuit failed high
22 P 91 4 TPS circuit failed low
23 s 65 3 Oxygen content circuit failed high
23 P 174 3 Chain fuel temperature. Short circuit in the power
24 s 65 4 Oxygen content circuit failed low
24 p 174 4 Chain fuel temperature. Short circuit in the ground
25 no codes
26 s 25 November Aux. shutdown # 1 active
26 S 61 11 Aux. shutdown # 2 active (Incorrect SID. subject to change)
27, p 105 3 circuit temperature in the reservoir. Short circuit in the power
27 p 171 3 Ambient air temp circuit failed high
27 p 172 3 Air temp, circuit failed high
28, p 105 to 4 Chain manifold temperature. Short circuit in the ground
28 p 171 4 Ambient air temp circuit failed low
28 p 172 4 Air temp, circuit failed low
29 p 404 4 TCO temperature circuit failed low
29 p 351 4 TCI Temperature circuit failed low
31 S 51 3 Aux. Output # 3 open circuit (high side) S3
31 S 51 4 Aux. Output # 3 short to ground (high side) S3
31 S 51 7 Aux. Output # 3 mech. system fail S3
31 s 52 3 Aux. Output # 4 open circuit (high side) T3
31 s 52 4 Aux. Output # 4 short to ground (high side) T3
31 s 52 7 Aux. Output # 4 mech. system fail T3
32 S 238 3 SEL short to battery B1
32 S 238 4 SEL open circuit B1
32 s 239 3 CEL short to battery B2
32 s 239 4 CEL open circuit B2
33 p 102 3 Boost pressure circuit failed high
34 p 102 4 Boost pressure circuit failed low
35 p 19 March Ext range oil pressure circuit failed high
35 p 100 3 Chain oil pressure. Short circuit in the power
36 P 19 April Ext range oil pressure circuit failed low
36 P 100 4 Chain oil pressure. Short circuit in the ground
37 P 18 March Ext range fuel pressure circuit failed high
37 P 94 3 Chain fuel pressure. Short circuit in the power
37 P 95 3 Fuel Filter Restriction circuit failed high
38 P 18 April Ext range fuel pressure circuit failed low
38 P 94 4 Chain fuel pressure. Short circuit in the ground
38 P 95 4 Fuel Filter Restriction circuit failed low
39 S 146 2 Mechanical error EGR valve
39 S 146 12 Mechanical error EGR valve
39 S 146 return valve 7 does not meet the exhaust
39 S 147 2 turbocharger control mechanism does not respond
39 s 147 12 turbocharger control mechanism does not respond
39 s 14 147 current returns exhaust gases enough
39 S 147 11 turbocharger control mechanism does not respond
39 S 147 7 turbocharger control mechanism does not respond
41 S 21 0 Too many SRS (missing TRS)
42 S 21 January Too few SRS (missing SRS)
43 p 111 1 Low coolant level
44 p 52 0 ntercooler coolant temp, high
44 p 105 0 temperature in the reservoir above the norm
44 p 110 0 antifreeze temperature above normal
44 p 172 0 Air inlet temp, high
44 p 175 0 Oil temperature above normal
45 p 19 January Ext range oil pressure low
45 p 100 1 Oil pressure below normal
46 p 168 1 Low voltage batteries
46 S 214 1 RTC Backup Battery Voltage Low
46 S 232 1 Sensor Supply Voltage Low A3 & W1
P 0 47 18 Ext range fuel pressure high
P 47 94 0 The fuel pressure above normal
47 p 0 102 Turbo boost press high
47 p 106 0 Air inlet pressure high or TCBV diff press high
47 p 164 0 Injection control pressure high
48 p 18 January Ext range fuel pressure low
48 p 94 1 fuel pressure below normal
48 p 106 1 Air inlet pressure low
48 p 164 1 Injection control pressure low
48 p 351 1 TCI Temperature below range
48 p 404 1 TCO Temperature below range
48 p 411 1 EGR Delta pressure low
48 p 412 1 EGR Temperature low
49 p 351 0 TCI Temperature above range
49 p 404 0 TCO Temperature above range

More Fault Codes here Detroit Disel DTC

on Dec 20, 2016 | Cars & Trucks

1 Answer

Error code P1446 on a 2002 Subaru Outback


P1446 Subaru
P1446 Subaru - Fuel Tank Sensor Control Valve Circuit Low

Possible causes
- Faulty Fuel Tank Sensor Control Valve
- Fuel Tank Sensor Control Valve harness is open or shorted
- Fuel Tank Sensor Control Valve circuit poor electrical connection

Read more: http://engine-codes.com/p1446_subaru.html#ixzz3XW7JPocn

Feb 17, 2013 | 2002 Subaru Outback

2 Answers

Where is the expansion valve located on the 2004 KIA Sedona


Kia Sedona expansion FRONT valve located under dash, behind glove box, fan and coil. Evacuate freon first. Disconnect Freon lines from firewall., Lay right front seat back to flat horizontal position and lay on top or totally remove the seat for easier working access. Remove under dash cover, fan, glove box, coil housing, remove coil mounting bolts, remove old expansion valve. (Inspect old valve, if debris inside, blow out coil before installing new valve. If visible debris best to consider replacing REAR expansion valve and DRIER/FILTER in front of radiator too and blow out all lines and coils while servicing.) Use compressor oil to lubricate "O" rings on new FRONT or REAR expansion valve, install valve bolts, reinstall coil bolts to FRONT firewall or REAR frame, reconnect freon lines to firewall in engine compartment. Evacuate AC system, install freon (35 1/2 ounces, nominal 3 pounds), check system for leaks, check for proper operation, enjoy.

Sep 12, 2012 | 2004 Kia Sedona

1 Answer

Where is the orifice tube located on 88 buick park avenue


Inspect/Test/Replace To raise pressure, there must be a restriction in the air conditioning system. The restriction divides the system into the high side and the low side. The terms high side and low side refer to the high pressure and low pressure within the system.
The flow control can be either an orifice tube or a metering device called an expansion valve. A thermostatic expansion valve controls the amount of refrigerant that is allowed to flow to the evaporator. A temperature sensing bulb on the evaporator inlet controls the expansion valve.
  • A bad expansion valve will cause low readings on both the low and high side.
  • Failure of the sensing bulb is the most common problem.
  • Sometimes the valve can become plugged with debris.
  • If the sensing capillary tube is warm, there is high pressure that pushes on the diaphragm.
  • The sensing bulb checks the temperature of the outlet line of the evaporator.
  • If it is warm, it opens the valve.
  • Pressure on top of the diaphragm tries to push the valve open.
  • The operation of the expansion valve can be checked.
  • Some expansion valves can be cleaned, repaired or adjusted.
f73-15a.gif This system uses an expansion valve as it's flow control device. Some expansion valves are wrapped with insulation. When the sensing bulb is in the evaporator case, it does not need to be wrapped because it stays cold. When an expansion valve is packed in that type of system, it is only to silence the noise that the evaporator makes.

CAUTION
Only EPA-certified technicians can purchase R-12 refrigerant, since proper recovery and recycling techniques are required to prevent damaging the environment. Improper disposal of R-12 refrigerant can result in a fine.

Jun 06, 2012 | Buick Park Avenue Cars & Trucks

1 Answer

2006 Subaru Outback Hatchback lock doesn't work. Subaru mechanic said it needed a tailgate wiring harness--total cost $400.00. Only one wire deffective. Why does it need such an expensive part? Mike...


Hi,

I believe that because your vehicle is relatively new is the reason that the subaru mech wants to use original equipement. He/she also makes a bit more money if they do the work that way.

This is one of those times that you may want to get a second and third opinion, no need for hip replacement when vitamins will do.

The $400 should be spent when you have exhausted all avenues.

Check online for your local subaru forum and ask them for a mech who will probably have more understanding than your current guy...


Hope that helps.

G.

Feb 08, 2011 | 2006 Subaru Outback

1 Answer

A backyard mechanic gave my 2001 outback an old change. However he drained the tranny instead, then when replacing the tranny fluid he wrongly put over 3 quarts into the transfer case on the passenger...


To drain the transfer case, you will need to **** out the fluid some, you can get a hand held pump at your local auto store. Then you will need to make sure that you add the proper transfer case fluid, then drain it again, then add the proper amount. Good luck with this, and my suggestion is to make sure that you hire on a mechanic that is certified, Lic, and bonded, or take it to a shop.

Nov 08, 2010 | 2001 Subaru Outback

1 Answer

AC problem with 2001 Montana passenger van


Did you replace the expansion valve?
Also try adding just a little more freon and see if that makes a difference....is there a sight glass you can view with the system activated to be sure you have it completely air free?

Jul 21, 2010 | 2001 Pontiac Montana

2 Answers

04 Saturn Vue AC blows cool air for about one minute then hot air


Above solution is correct, had the same problem with mine and it was the expansion valve.

Jul 06, 2010 | 2004 Saturn VUE

2 Answers

99 Toyota Tacoma a/c reads high pressure on low pressure side


Does the compressor run?
Low side could be high without a running compressor.

A running compressor?
The expansion valve itself is about $50 and bolts in.
You will have to remove the 134a gas before installing a replacement expansion valve and vacuum the system before recharging.

Sep 07, 2009 | 1999 Toyota Tacoma PreRunner

Not finding what you are looking for?
2003 Subaru Outback Logo

278 people viewed this question

Ask a Question

Usually answered in minutes!

Top Subaru Experts

yadayada
yadayada

Level 3 Expert

70374 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22041 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

6878 Answers

Are you a Subaru Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...