Question about 1996 Jeep Grand Cherokee

Open Question

My heater/ac fan doesn't work. I replaced the blower motor and checked my fuses. Is there a relay I need to check?

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 958 Answers

SOURCE: Blower for AC/Heater stopped working

if you can reach the blower motor, it could be a worn out carbon brush of the blower motor. if they are, buy a set of carbon brush, learn how to replace them and it would be back running in no time. by the way, when you pull out the carbon brush holder, make sure you dont interchange the position. you can put them back wards and what would happen is the rotation will be reversed. either you reversed the carbon brush holder or just simply interchange the wires that are coming to the motor. i hope i was able to help...

Posted on Jul 07, 2008

Ad
  • 1 Answer

SOURCE: 2001 BMW 525I Heater/AC Blower-Fan Motor not pushing out air

hedgehog is a final stage unit located on passenger side deep behind the radio. Replace my batt before fiding the post. did my self and part cost about 70.00 bucks but area is very tight. The fuses 75 and 76 are located behind the glove box and very difficult to get to and see. I am trying to find the solution to that as we speak.

Posted on Jan 18, 2009

  • 135 Answers

SOURCE: I have a 2006 Chev Impala that the fan does not operate,

underhood fuse block think it says BATT 4 30amp prob. going to be bad blower resistor

Posted on Aug 05, 2009

SOURCE: blower motor does not work

I had the same problem, replace, replace, replace. Check, check and recheck. What I found was the blower motor resistor, located in the blower squirrel cage area, two prongs and a curly wire, was bad. Took the new one back, (it ohmed out okay, continuity ok, all ok!) replaced it with another, and Bingo, problem solved. Frustrating to say the least. After two relays and a blower switch, and test, test and retest. It was a faulty resistor. Made in Mexico. And no guarentee, even though new, it works. Trial and error. Even the dealer parts are Honcho en Mexico. Thanks NAFTA. You gonna make us all welfare babies.

Posted on Sep 28, 2009

  • 18 Answers

SOURCE: Heater Blower won't work

There was a bulletin reguarding water contaminating the blower motor, which overheats the blower resistor and renders it inoperative. The fix was to replace the blower and the resistor and seal the culprit hood cowl screw at the base of the windshield, which is the second screw from the passenger side. They say water drips off of it down into the fresh air opening.
Here's what I'd do: Assuming your switch and blower motor is good, replace the blower resistor. Remove the blower motor and see if it spins without any excessive drag. If it's okay, reuse it. If it's dragging, it will overheat your new resistor in a short period of time and you'll be back at square one. The blower resistor is mounted to the front of the case with 2 screws to the left of the blower motor. Remove the glove box and you'll see it.
The Hood cowl screw is straight down into the cowl, the second one from the right side, about 10-12 inches from the right fender. Pull it out, put some sealer on it, and reinstall it.

Posted on Oct 02, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

2005 dodge durango front heater/ac blower motor doesn't work


Check fuses and relays. On relay just switch with one you no works.

Feb 20, 2013 | 2003 Dodge Durango

1 Answer

Heater blower motor doesn't run


check under your dash by the fuse box might be there

Mar 24, 2012 | 1998 GMC Sierra

1 Answer

Heater/ac blower motor does not work,,, check fuses, didnt check blower resistor,


CHECK BLOWER MOTOR RELAY ALSO, AND USE A TEST LIGHT TO SEE IF POWER GOING TO BLOWER MOTOR, IF YES BLOWER MOTOR FAULTY.IF NO POWER GOING TO BLOWER MOTOR AND FUSE AND RELAY OKAY CONTROL SWITCH COULD BE BAD,A RESISTOR BAD MOST OF THE TIME IF YOU DONT HAVE BUT A FEW FAN BLOWER CONTROL SPEEDS.

Jul 22, 2011 | 1999 Oldsmobile Alero

1 Answer

My 1991 isuzu trooper heater blower fan is not working, nor when i turn it to the airconditioner the compressor does not engage. i checked all the fuses except the ac relay fuse block, what could the...


if the lower fan speeds dont work but the fastest speed does the heater fan resistor block needs replacing. If the highest fan speed doesnt work leave it on there and check for power at heater blower fan, if power is on one wire and the other is an earth the blower motor fan needs replacing. Use a normal globe test light to check this. If no power on any wires to fan go back and check all fuses in car and under bonnet with same test light. If fuses are ok possible open circuit wire to fan.

Jan 13, 2011 | 2004 Isuzu Rodeo

2 Answers

The heater fan is not working. Is it a fuse?


fuses are the easy thing to check just pull one and look at it if you see a burned spot replace it, checking relays and blower motor resesters and blower motors are harder if you dont know how to do it. there best left to a shop to check.

Dec 16, 2010 | 1999 Plymouth Voyager

1 Answer

My 97 buick lesabre limited heater/ac blower quit, it has the climate control,I checked all fuses.


REMOVE HEATER BLOWER MOTOR HOT WIRE BLOWER MOTOR IT.IF IT WORKS.YOUR AC AND HEATER CONTROL SWITCH IS FAULTY.CHECK HVAC FUSES AND CHECK BLOWER MOTOR RELAY.IF BLOWER MOTOR DONT WORK WHEN HOT WIRE REPLACE IT.IF ALL CHECK OUT GOOD.HAVE DEALERSHIP DO A DIAGNOSTIC TEST ON YOUR CLIMATE CONTROL SYSTEM.

Dec 02, 2010 | 1997 Buick LeSabre

10 Answers

1997 Isuzu Rodeo V6 4X4. I have only owned this vehicle for 3wks and the fan/ac wont blow at all out the vents. The blue light comes on when i push the ac button but that is all it does. I don't know which...


C-19 Blower motor fuse 25A located in cabin fuse box. Left hand footwell on LHD vehicles, right hand dashboard on RHD vehicles.
Start by checking blower relay B-36 in the engine compartment fuse and relay box. Remove the relay. Jumper directly from battery to pins 85 and 86. (also see here: http://www.fixya.com/cars/r5544622-wire_relay if you dont know about relays) The relay should click Now measure across pins 30 and 87. Measurement should be 0 ohm.
Remove the blower motor(3 screws on the bottom of the unit under the passenger side dash) and connect jumper leads from the battery directly to the blower motor to see that it operates.
The blower motor resister is mounted on the ducting between the motor housing and the heating unit. Remove to test
Measure :
  • pin 1-2 : 2.4 ohm
  • pin 2-4 : 0.9 ohm
  • pin 2-6 : 0.28 ohm
  • pin 2-3 : 0 ohm

Aug 21, 2010 | 1997 Isuzu Rodeo

2 Answers

Where is the heater fan relay located on 1990 mercedes 190e


If the heater is not working (fan is not turning), but you are able to press the climate control buttons to activate the AC and venting, then the relay (actually this is the ACC in the dash with the buttons, there is no separate relay that controls the AC/Heater fan) is not the problem. Check the fuse box in the right side engine compartment, then check the long 3A flat fuse located in a coverd case atop the the wheel well in front of the fuse box. If these are okay, the fan motor is the problem. If the motor needs to be replaced, you'll need to remove the front cowl under the windshield, and also the windshield wiper assembly. The motors usually bind after 20+ years and need to be replaced. Sometimes, they will bind, then work again. Sometimes they'll bind and blow the long fuse. The job takes about 2 hours and the motor is about $150-$250.

Jan 10, 2010 | 1990 Mercedes-Benz 190

1 Answer

Ac blower motor


Check fuse supplying fan is not blown,
Check blower control switch is operating OK,
Check relay controlling fan is operating OK,
Check variable speed resistor pack is not faulty (the resistor pack is usually located in the blower ducting, in the blower airflow),
Check blower motor ground connection is not missing.

Aug 12, 2009 | 2000 Mercury Grand Marquis

2 Answers

1983 Chevrolet Suburban Heater fan not working


Heater blower motor resister is bad, replace, located under dash above heater motor.

Mar 15, 2009 | 1983 Chevrolet Suburban

Not finding what you are looking for?
1996 Jeep Grand Cherokee Logo

Related Topics:

75 people viewed this question

Ask a Question

Usually answered in minutes!

Top Jeep Experts

yadayada
yadayada

Level 3 Expert

76164 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

Kevin Daniels

Level 3 Expert

1455 Answers

Are you a Jeep Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...