Question about 2001 Dodge Caravan

1 Answer

Only high speed on a/c fan - 2001 Dodge Caravan

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 14 Answers

Heater fan resistor is burned out. If you change it also change heater motor as it is overloading resistor.

Posted on Sep 15, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

When i start my 2008 Cadillac sts i get a notification that engine hot A./C off. Even though it is the first time i stated it today


ENGINE HOT - AC OFF
Cooling System Description and Operation

you must have a cooling system problem of some sort !

Do the cooling fans come on when A/C is switched on ? Fan's should come on ! Does your vehicle have two or three cooling fan's ?
Cooling Fan Control - Two Fan System
The engine cooling fan system consists of 2 puller type electrical cooling fans and 3 fan relays. The relays are arranged in a series parallel (S/P) configuration that allows the engine control module (ECM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood fuse block. The ground path is provided at G104.
During low speed operation, the ECM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the low speed fan relay coil, closes the relay contacts, and supplies battery positive voltage from the low fan fuse through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan S/P relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation the ECM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. After a 3 second delay, the ECM supplies a ground path for the high speed fan relay and the cooling fan S/P relay through the high speed cooling fan relay control circuit. This energizes the cooling fan S/P relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time, the high speed fan relay coil is energized closing the relay contacts, and provides battery positive voltage from the high fan fuse on the cooling fan motor supply voltage circuit, to the right cooling fan. During high speed fan operation, both engine cooling fans have their own ground path. The result is a parallel circuit with both fans running at high speed.
The ECM commands the low speed cooling fans ON under the following conditions:
• Engine coolant temperature exceeds approximately 94.5°C (202°F).
• A/C refrigerant pressure exceeds 1447 kPa (210 psi).
• After the vehicle is shut OFF, if the engine coolant temperature at key-off is greater than 101°C (214°F), the low speed fans will run for a minimum of 60 seconds. After 60 seconds, if the coolant temperature drops below 101°C (214°F), the fans will shut OFF. The fans will automatically shut OFF after 3 minutes, regardless of coolant temperature.
The ECM commands the high speed fans ON under the following conditions:
• Engine coolant temperature exceeds approximately 104.25°C (220°F).
• A/C refrigerant pressure exceeds approximately 1824 kPa (265 psi).
• When certain DTCs set
At idle and very low vehicle speeds the cooling fans are only allowed to increase in speed, if required. This ensures idle stability by preventing the fans from cycling between high and low speed.
Cooling

Having a qualified professional technician check it out would be your best bet ! Hooking up a factory or professional type scanner an check data input's an DTC'S - diagnostic trouble codes .

Diagnostic Starting Point - Engine Cooling
Begin the system diagnosis with the diagnostic system check. Refer to Diagnostic System Check - Vehicle . The Diagnostic System Check - Vehicle will provide the following information:
• The identification of the control modules which command the system
• The ability of the control modules to communicate through the serial data circuits
• The identification of any stored DTCs and their status
The use of the Diagnostic System Check - Vehicle will identify the correct procedure for diagnosing the system and where the procedure is located.

DTC P0480: Cooling Fan Relay 1 Control Circuit
DTC P0481: Cooling Fan Relay 2 Control Circuit
DTC P0480: Cooling Fan Relay 1 Control Circuit
DTC P0481: Cooling Fan Relay 2 Control Circuit
DTC P0691: Cooling Fan Relay 1 Control Circuit Low Voltage
DTC P0692: Cooling Fan Relay 1 Control Circuit High Voltage
DTC P0693: Cooling Fan Relay 2 Control Circuit Low Voltage
DTC P0694: Cooling Fan Relay 2 Control Circuit High Voltage
DTC P1258: Engine Coolant Overtemperature - Protection Mode Active
DTC P2600: Auxiliary Coolant Pump Relay Control Circuit
DTC P2601: Auxiliary Coolant Pump Performance
DTC P2602: Auxiliary Coolant Pump Relay Control Circuit Low Voltage
DTC P2603: Auxiliary Coolant Pump Relay Control Circuit High Voltage

Dec 10, 2017 | Cadillac Cars & Trucks

1 Answer

I have a 2006 buick lucerne 3.8 v6 cxl.my coolinf fans dont come on .i need to know how to change the relay and the fuse.


Your vehicle cooling fan's are controlled by three relay's , couple of fuse's an the PCM - engine computer . The engine coolant temp. sensor is a input to the PCM , when engine temp get's to 212 the PCM will turn on the cooling fans in low speed . Checking to see what the actual temp is with a scan tool an a infrared thermometer at the thermostat housing ,an looking up the specification's in a service repair manual is how to diagnose . Not guessing an replacing parts . Plus learning how the cooling fan's work .
Relay Driven Dual Cooling Fan Diagnostics Reading factory service info as to how they work also would be a good idea .

Cooling Fan Control - Two Fan System
The engine cooling fan system consists of 2 puller type electrical cooling fans and 3 fan relays. The relays are arranged in a series parallel (S/P) configuration that allows the engine control module (ECM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood fuse block. The ground path is provided at G104.
During low speed operation, the ECM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the low speed fan relay coil, closes the relay contacts, and supplies battery positive voltage from the low fan fuse through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan S/P relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation the ECM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. After a 3 second delay, the ECM supplies a ground path for the high speed fan relay and the cooling fan S/P relay through the high speed cooling fan relay control circuit. This energizes the cooling fan S/P relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time, the high speed fan relay coil is energized closing the relay contacts, and provides battery positive voltage from the high fan fuse on the cooling fan motor supply voltage circuit, to the right cooling fan. During high speed fan operation, both engine cooling fans have their own ground path. The result is a parallel circuit with both fans running at high speed.
The ECM commands the low speed cooling fans ON under the following conditions:
• Engine coolant temperature exceeds approximately 94.5°C (202°F).
• A/C refrigerant pressure exceeds 1447 kPa (210 psi).
• After the vehicle is shut OFF, if the engine coolant temperature at key-off is greater than 101°C (214°F), the low speed fans will run for a minimum of 60 seconds. After 60 seconds, if the coolant temperature drops below 101°C (214°F), the fans will shut OFF. The fans will automatically shut OFF after 3 minutes, regardless of coolant temperature.
The ECM commands the high speed fans ON under the following conditions:
• Engine coolant temperature exceeds approximately 104.25°C (220°F).
• A/C refrigerant pressure exceeds approximately 1824 kPa (265 psi).
• When certain DTCs set
At idle and very low vehicle speeds the cooling fans are only allowed to increase in speed, if required. This ensures idle stability by preventing the fans from cycling between high and low speed.

Dec 10, 2017 | Buick Cars & Trucks

1 Answer

How to replace coolig fan sending unit on a 2008 chevy uplander


Why ? Did you test ? Hook up a scan tool to see if the PCM/ECM - engine computer is reading coolant temp. ? Testing not guessing ? Do you even know how the system works .

The engine cooling fan system consists of 2 electrical cooling fans and 3 fan relays. The relays are arranged in a series/parallel configuration that allows the engine control module (ECM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood fuse block.
During low speed operation, the ECM supplies the ground path for the low speed fan relay, which is Fan 1 Relay, through the low speed cooling fan relay control circuit. This energizes the low speed fan relay coil, closes the relay contacts, and supplies battery positive voltage from Fan 1 Fuse 29 through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the Series/Parallel relay, which is the Fan 2 Relay, and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation the ECM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. The ECM supplies a ground path for the high speed fan relay, which is the Fan 3 Relay, and the Series/Parallel through the high speed cooling fan relay control circuit. This energizes the Series/Parallel relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time the Fan 3 Relay coil is energized, the relay contacts close to provide battery positive voltage from Fan 2 Fuse 33 on the cooling fan motor supply voltage circuit to the right cooling fan. During high speed fan operation, both engine cooling fans have their own ground path. The result is a parallel circuit with both fans running at high speed.
When the request for fan activation is withdrawn, the fan may not turn OFF until the ignition switch is moved to the OFF position or the vehicle speed exceeds approximately 10 mph. This is to prevent a fan from cycling ON and OFF excessively at idle.

Feb 27, 2017 | 2008 Chevrolet Uplander

1 Answer

Fan is not working on 2001 Chevy Silverado 2500 truck radiator fan motor?


The engine cooling fan system consists of 2 electrical cooling fans and 3 fan relays. The relays are arranged in a series/parallel configuration that allows the powertrain control module (PCM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood fuse block.
During low speed operation, the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the low speed fan relay coil, closes the relay contacts, and supplies battery positive voltage from the low fan fuse through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan s/p relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. After a 3 second delay, the PCM supplies a ground path for the high speed fan relay and the cooling fan s/p relay through the high speed cooling fan relay control circuit. This energizes the cooling fan s/p relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time the high speed fan relay coil is energized closing the relay contacts and provides battery positive voltage from the high fan fuse on the cooling fan motor supply voltage circuit to the right cooling fan. During high speed fan operation, both engine cooling fans have there own ground path. The result is a parallel circuit with both fans running at high speed.
Your best bet would be to take your vehicle to a qualified repair shop !
Relay Driven Dual Cooling Fan Diagnostics

Aug 19, 2016 | 2001 Chevrolet Silverado 2500

1 Answer

Engine cold. Start engine reading says engine hot ac off. Fans run all time.


Are the fans running on low or high ?
Circuit/System Description
The engine control module (ECM) commands the fans ON in either high speed or low speed, depending on cooling requirements. In low speed, both fans are turned ON at a reduced speed. High speed has both fans turned ON at full speed.
In low speed operation, the ECM applies ground to the coil side of the fan low relay. This energizes the coil and applies voltage directly to the left cooling fan through the switch side of the fan low relay, which is fed by the fan 1 fuse. The right fan is connected in series to the left fan through the de-energized fan control relay so that both operate at low speed.
In high speed operation, the ECM applies a ground to the coil side of the fan low relay, the fan control relay , and the fan high relay. On the fan high relay, the energized coil closes the switch side of the relay and applies voltage directly to the right cooling fan through the switch side of the relay, which is fed by the fan 2 fuse. At the same time, the ECM energizes fan control relay pulling the switch side over, providing a direct path to ground for the left cooling fan, which has voltage applied through the energized fan low relay. In high speed mode, the fans are operated as a parallel circuit with full voltage applied to each.
You should have it hooked up to a scan tool that can read engine sensor data parameters . Check for DTC'S - diagnostic trouble codes etc...
Circuit/System Verification
  1. If DTCs P0480 or P0481 are set, perform those diagnostics first.
  2. Ignition ON, verify with a scan tool that the control module is not commanding fan activation.
  3. Ignition ON, observe that the fans are not activated.
Your best bet is to take it to a ASE certified repair shop !

Jan 10, 2016 | 2009 Chevrolet Silverado 1500

1 Answer

3 speed fan barely changes speed


You are talking about your blower fan for the air conditioner and heater right? More information will be needed to solve the problem.

When you say it barely changes speeds, does that mean it doesnt speed up, or doesnt slow down? By that I mean, is it "stuck" on low, or high?

Most blower fans run at different speeds through the use of a multi-stage resistor built into the fan switch circuit. Low speed is a high value resistor, medium speed is a low value one, and high speed is the fan running without any resistance.

If your fan is running on high and doesnt seem to want to run on lower speeds, the resistor pack may be failing. If the fan is running on low speed only, it may be that the fan itself is beginning to fail, or that the lubricant in it has gotten gummy.

Dec 07, 2015 | Cars & Trucks

1 Answer

My car 2008 Chevy Uplander warning light came on stating A/C shut off for engine protection. My question exactly as 1posted 2011. Gauge not Reading. Fan running continuously. Doesn't seem hot.


What gauge not reading , Temperature ? you posted back in 2011 ? You did feel you should take it to the repair shop ? You need to take this to a ASE certified repair facility ! This is a complex electronically controlled cooling system , Three relay's controlled by the ECM -engine control module turn the fans on in two different speeds ! There could be DTC'S diagnostic trouble codes stored in the ECM, HVAC module , BCM !
Circuit/System Description
The engine control module (ECM) commands the fans ON in high speed or low speed. In low speed, the fans are configured in series. In high speed, the fans are configured in parallel.
In low speed operation, the ECM applies ground to the coil side of the low speed fan relay, which is the Fan 1 Relay. Voltage is applied directly to the left cooling fan through the switch side of the low speed fan relay. The right fan is connected in series to the left fan through the de-energized Series/Parallel relay, which is Fan 2 Relay, so that both fans operate at low speed.
In high speed operation, the ECM applies a ground to the coil side of the low speed fan relay, the Series/Parallel relay, and the high speed fan relay, which is the Fan 3 Relay. Voltage is applied directly to the right cooling fan through the switch side of the high speed fan relay. The left cooling fan obtains voltage through the low speed fan relay and ground through the Series/Parallel relay.
When the ECM is commanding a fan relay ON, the voltage of the control circuit should be low, near 0 volts. When the ECM is commanding a fan relay OFF, the voltage of the control circuit should be high, near battery voltage.
One of the relays could be stuck on ! An for the gauge you have to have it removed an fixed , there is a stepper motor behind the gauge needle an they go bad ! Or replace the instrument cluster !

May 14, 2015 | Cars & Trucks

1 Answer

My ac is not working I have a Chevy Tahoe 2005 the fans won't turn on either .


Hi Maria , The A/C system wouldn't keep the fans from running but none working cooling fans will keep the A/C from working ! This is a fairly complex system if your not familiar with this sort of thing ! I will add the description from the factory service manual.
Cooling Fan Control - Two Fan System
The engine cooling fan system consists of 2 electrical cooling fans and 3 fan relays. The relays are arranged in a series/parallel configuration that allows the powertrain control module (PCM) to operate both fans together at low or high speeds. The cooling fans and fan relays receive battery positive voltage from the underhood fuse block.
During low speed operation, the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. This energizes the low speed fan relay coil, closes the relay contacts, and supplies battery positive voltage from the low fan fuse through the cooling fan motor supply voltage circuit to the left cooling fan. The ground path for the left cooling fan is through the cooling fan s/p relay and the right cooling fan. The result is a series circuit with both fans running at low speed.
During high speed operation the PCM supplies the ground path for the low speed fan relay through the low speed cooling fan relay control circuit. After a 3 second delay, the PCM supplies a ground path for the high speed fan relay and the cooling fan s/p relay through the high speed cooling fan relay control circuit. This energizes the cooling fan s/p relay coil, closes the relay contacts, and provides a ground path for the left cooling fan. At the same time the high speed fan relay coil is energized closing the relay contacts and provides battery positive voltage from the high fan fuse on the cooling fan motor supply voltage circuit to the right cooling fan. During high speed fan operation, both engine cooling fans have there own ground path. The result is a parallel circuit with both fans running at high speed.
Do you have a check engine light lit ? The thing to do would have it check at the dealer or a ASE certified repair facility ! They could hook up a advanced scan tool an diagnose fairly quick ! Or you could find a wiring diagram an try testing with a volt meter yourself ! But watch yourself so you don't short out the PCM - engine computer !

May 01, 2015 | AC Cars & Trucks

1 Answer

ON a 2006 HHR LT is there separate fuses for the three fan speeds. The high fan speed is working but th low and medium speeds are not. Where are the fuses located


the fan speeds work through a blower motor resistor and not separate fuses for each speed. when these resistors go bad they are designed to work on high speed only.

Oct 11, 2014 | 2006 Chevrolet HHR LT

Not finding what you are looking for?
2001 Dodge Caravan Logo

Related Topics:

50 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dodge Experts

yadayada
yadayada

Level 3 Expert

80339 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22326 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6927 Answers

Are you a Dodge Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...