1 Answer

Air conditioner full of coolant but blowing warm air.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Legend:

    An expert who has written 200 answers of more than 400 characters.

  • Expert
  • 251 Answers

A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner, the first thing to check is whether the unit is getting proper power. If the unit uses 220 volt power be sure that the proper voltage is getting to the unit. Same for 110 volt units. A voltage meter can be used to assure that the voltage is correct.

For window air conditioning units the voltage can also be checked before and after the thermostat. If voltage is being supplied to the thermostat but not from it then the thermostat probably needs replaced. This is a fairly common problem. Another place to check is the fan motor voltage. The fan on window air conditioners runs both the indoor blower and the condenser fan. If that motor fails than the compressor may run for a short time, but will overheat and shut off. Continued operation like this will result in compressor failure. This motor can be economically replaced for larger window air conditioners, but for smaller ones the cost of replacement will be more than a new unit.

Central air conditioners for the home are more complex and there are more things that can go wrong. As with the window air conditioner the thermostat can also be a problem. The central air conditioner thermostat will only have 24 volts going to it. So don't look for high voltage there. Some units the voltage will be coming from the outdoor unit and others the voltage will be supplied by the indoor air handler or furnace. Most home central air conditioning will be supplied by the indoor air handler or the furnace. If the air conditioner is for cooling only the unit will usually have only two wires going to the condenser unit. Make sure that you have 24 volts across those wires.

The next thing to check will be the indoor blower. If your thermostat is calling for cooling then the indoor blower should be running. If there is no air moving across the indoor cooling coil then you will soon have a big block of ice formed on the coil. This can happen for a few reasons. The indoor blower is not working, the air flow is restricted and not allowing air to move across the coil. A clogged air filter would also do this. Or the outdoor condenser unit has lost the charge of refrigerant.

Finally and worst of all is when you have a complete compressor failure. Often when this happens the compressor will "lock up" or not be able to turn when power is supplied to it. Overheating or lack of lubrication are usually the main causes of compressor failure. Overheating can be caused by the outdoor coil around the compressor getting clogged with dirt, leaves, or grass. Loss of the refrigerant charge will also cause the compressor to overheat. It is the cool return gas coming back to the compressor that helps to keep it from overheating.

As you can see there are many things that can go wrong with an air conditioner and I have not come close to exhausting the possibilities here. I have just touched on the most common problems in a very basic way.
There are some basic trouble shooting things that can be done very easily. Most problems are above out of the range of comfort for many homeowners and professional help should be consulted before any attempt is made at repairs. Remember also, that the release of refrigerant gases into the atmosphere is a federal offense in the
US. Proper care must always be taken to minimize the release of any gases. A license is also required to handle refrigerants. Make sure that the professional you call has the proper certifications to handle refrigerants properly.


http://www.fixya.com/support/r3636709-size_air_conditioner_need

http://www.fixya.com/support/r3623253-window_air_conditioners_clean_every_year

http://www.fixya.com/support/r3633369-portable_air_conditioning_great_portable

http://www.fixya.com/support/r3623166-heating_air_conditioning_scams

http://www.fixya.com/support/r3597468-you_can_add_air_conditioning_to_your_hot

http://www.fixya.com/support/r3583697-how_to_keep_house_cool_without_using_air

Posted on Jun 07, 2011

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

2002 Ford Taurus, Heater blows cold air?


What have you checked so far ?
Radiator full of coolant ? Heater hoses getting hot ?

Feb 23, 2015 | 2002 Ford Taurus

1 Answer

2003 alero blows air no hot air


If the heater hoses are hot, it could be a blend door problem under the dash.

Jan 19, 2014 | 2003 Oldsmobile Alero

1 Answer

Heater issue


This sounds like a thermostat that is fully open all the time. It allows the engine coolant to warm when sitting still (no air being forced thru the radiator), but even that goes away when moving, since the air through the radiator will remove that heat from the coolant. Does you van have a temp gauge? Is so, at full operating temp. most vehicles have coolant temps of 180-195 degrees F, depending on the thermostat installed. Anything less indicates a thermostat that is starting to malfunction.

Dec 08, 2013 | 2000 Mercury Villager

1 Answer

Heater isnt blowing warm air in 2003 grand caravan


Assuming the radiator is full of coolant, you are describing a faulty thermostat. The thermostat is closed when the engine is cold to restrict coolant flow until it warms up.

Feb 01, 2013 | 2003 Dodge Caravan

1 Answer

Air conditioner


Check whether the warm air isn't going in with the cold air .Coolant line that runs into the firewall on the passenger side of the engine which is toward the bottom half of the firewall on the passenger side. If there is warm air going into the vents with the cold air then it blows warm air. You may have to shut it manually because it gets stuck sometime. Check it out.

Jul 24, 2012 | 2005 Honda Accord

2 Answers

When the car is idling, the heater blows out cool air but when the car is moving, the heater works fine


When the coolant in the heater core is hot from the engine and your fan is on hot air will blow through the hot fan coil, i figured it out, when i stepped on the gas i could here the coolant squeezing by the control or limiter valve, because the higher rpms make the belt spin faster which makes the water pump pump harder causing more pressure, so when u idle that hot coolant will cool down from the fan blowing on it, u need to find the control valve and open it up to full blast, then hot coolant will always be flowing through your heater coil. ;)

Dec 17, 2010 | 2008 Pontiac G6

1 Answer

Air conditioner blows hot air,


As long as the belt is turning the compressor than the only other thing would be that the refrigerant (R-134) is not full. You can buy re-charging kits at any local auto parts store, although they recommend that you have a licensed dealer remove the old refrigerant so it dosn't go into the atmosphere. Good luck.

May 10, 2009 | 1998 Dodge Durango

1 Answer

Air conditioner blows hot air, checked coolant and it is full


There are a few different possibilities for a vehicle doing this. A low refridgerant level can, or a temp control on the dash is not operating properly.

May 10, 2009 | 1998 Dodge Durango

2 Answers

Nissan Altima no cool air blowing or hot air blowing


Hi!
It appears we have an Air lock scenario and you will need to perform a system Bleed.
Park the vehicle on level ground, when cold remove coolant filler cap, start engine and leave to idle, turn heater on full and blower to max. When engine reaches operating temperature watch and listen near coolant filler, keep clear as gurgling and hopefully a boil over should occur. Top up with very warm coolant and wait as it may do it again.
Check for heat inside vehicle if warm replace coolant cap but keep an eye on temperature gauge as the ~Air lock may have moved on from heater matrix/core so proceedure needs to be carried out again from COLD.

Please press the Blue button to appraise my FREE Efforts, Thank You!
Paul 'W' U.K

Feb 24, 2009 | 2002 Nissan Altima

Not finding what you are looking for?
1992 Buick Regal Logo

123 people viewed this question

Ask a Question

Usually answered in minutes!

Top Buick Experts

yadayada
yadayada

Level 3 Expert

75822 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

8195 Answers

Are you a Buick Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...