3 Answers

I have a 1993 chevy 1500 and the a/c control will not come on no fan, no a/c not heat nothing there is power to the control it lights up but no controls. i purchased another unit and its the same problem

Posted by on

  • 2 more comments 
  • thurstn Aug 25, 2010

    would that cause the control unit not to even show anything? its the digital one

  • thurstn Aug 25, 2010

    there is nothing like that anywhere around the blower

  • thurstn Aug 25, 2010

    I have a 1993 chevy pick up, the a/c control lights up but the a/c wil not come on. no fan ,no heat ,no blower. i replced the head unit and still nothing. can anyone help

  • thurstn Aug 25, 2010

    it lights up the ground seems to be good is there any way of bypassing the control unit to rule it out

×

3 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 749 Answers

Were you able to verify the blower motor works?You can verify power to the blower motor with a test light and a good ground.If you then connect the light to the positive power supply you can check and make sure it has a good ground. Also you may want to check the blower resistor it controls the fan speed settings.I believe the blower motor is located on the passenger side firewall and the resistor is very close to it.

Posted on Aug 26, 2010

  • Jonathan S
    Jonathan S Aug 26, 2010

    You can directly wire the blower with jumper wires to power it up but you will not be able to switch where the air is blowing wherever the blend door is where it will stay for right now but you will at least know if the blower is good or not. Been awhile since working on one of these so the blower motor is either on the passenger firewall or on the passenger side under the dash.

×

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 1,297 Answers

If you have good power and a good control hear then check or replace the ground

Posted on Aug 25, 2010

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Chevrolet Master
  • 75,117 Answers

Have u replaced the blower motor speed control resistor? it has a thermal fuse that blows then the blower gets on power, it is located right next to the blower, it plugs into the air duct work for cooling, the is pictured below, about as big as a pack of smokes. it is cheap and avail in the aftermarket,here is the part number:
FOUR SEASONS Part # 20074 [Blower resistor)
I have a 1993 chevy - f7453e1.jpg

Posted on Aug 25, 2010

  • 1 more comment 
  • yadayada
    yadayada Aug 25, 2010

    It is near the blower, have replaced dozens of these, you didn't say the control was the automatic type, if it doesn't light up then the control head is either burned out or has no power, I suspect the control head is defective, it is fairly common on older trucks, you can either get the old one repaired or try and find a used one, use the web link below to locate a used AC automatic control head.

    http://www.usedwreckingyards.com/parts/c...

  • thurstn Aug 25, 2010

    i have replaced it. it lights up just has no controls

  • thurstn Aug 25, 2010

    and i did say it was replaced and it lites up just nothing works

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How to find fuse boxs


FUSE PANEL LOCATION
The fuse panel is located in the engine compartment. A label on the inside of the cover lists the fuse amperage and circuits protected.
volvo 850 fuses fuse panel layout service repair manual
FUSE PANEL IDENTIFICATION
Fig. 1: Fuse Panel Identification
Courtesy of Volvo Cars of North America.
WARNING: Always disconnect battery ground cable before servicing "high-current fuses. It is recommended that "high-current" fuses be replaced by a qualified technician.
* 1 - 15 Amp
Fuel Injection, Distributor Ignition, Automatic Gearbox
* 2 - 15 Amp
Fuel Pump, Alarm System
* 3 - 10 Amp
Courtesy Lights, Oil Level Sensor
* 4 - Not Used (1993-95)
* 4 - 10 Amp (1996)
Electronic Start Inhibitor (Immobilizer)
* 5 - 30 Amp
ECC Blower (Speed 4)
* 6 - 25 Amp
Central Locking System, Alarm
* 7 - 15 Amp
Audio System (Amplifier)
* 8 - 25 Amp (1993-95)
Power Antenna, Trailer Connector
* 8 - 40 Amp (1996)
Electronic Start Inhibitor (Immobilizer)
* 9 - 30 Amp
ABS, Traction Control System
* 10 - Not Used (1993-95)
* 10 - 15 Amp (1996)
Heated Rear Seat (If Equipped)
* 11 - 30 Amp
Heated Rear Window & Side Mirrors
* 12 - 10 Amp
Brake Lights
* 13 - 15 Amp
Hazard Flashers, Headlight Flashers, Alarm
* 14 - 30 Amp
ABS, Traction Control System
* 15 - 10 Amp (1993-95)
Audio System, Courtesy Lights, Door Open Light, Trunk Light, Glove Box Light, Remote Control Central Locking System,
Oil Level Sensor, Seat Belt Reminder
* 15 - 10 Amp (1996)
Audio System, Courtesy Lights, Door Open Light, Trunk Light, Glove Box Light, Remote Control Central Locking System,
Oil Level Sensor, Seat Belt Reminder, Data Link Connector
* 16 - 30 Amp (1993-95) Accessories
* 16 - 30 Amp (1996)
Power Antenna, Trailer Connector, Accessories
* 17 - 10 Amp
Key Reminder
* 18 - 25 Amp (1993-95)
Heated Front Seats, Power Mirrors
* 18 - 15 Amp (1996) Front Fog Lamps
* 19 - 15 Amp
Left High Beam Headlight
* 20 - 15 Amp
Right High Beam Headlight, High Beam Indicator
* 21 - 15 Amp
Left Low Beam Headlight
* 22 - 15 Amp
Right Low Beam Headlight
* 23 - 10 Amp
Left Parking Light, License Light
* 24 - 10 Amp
Right Parking Light, Bulb Failure Warning Sensor
* 25 - 10 Amp
Rear Fog Lamps, Fog Lamp Indicator
* 26 - Not Used (1993-95)
* 26 - 25 Amp (1996)
Heated Front Seats, Power Mirrors
* 27 - 15 Amp
Back-Up Lights, Turn Signals
* 28 - 10 Amp
Cruise Control, Heated Rear Window, Seat Belt Reminder Light, Shiftlock, Bulb Failure Warning Sensor, Heated Rear Seat
* 29 - 15 Amp
ABS, Traction Control System
* 30 - 10 Amp
Cigarette Lighter
* 31 - 25 Amp
ECC, ECC Blower (Speeds 1-3)
* 32 - 10 Amp
Audio System, Remote Controlled Central Locking System
* 33 - 15 Amp (1993-95)
Power Seats, OBD Test Socket, Tailgate Washer/Wipe (Wagon)
* 33 - 15 Amp (1996)
Power Seats, Tailgate Washer/Wipe (Wagon)
* 34 - 25 Amp
Windshield Wiper/Washer, Horn, Headlight Washer/Wiper
* 35 - 10 Amp
Instrument Lights, Sun Roof, Traction Control System
* 36 - Not Used
* 37 - Circuit Breaker
Power Windows, Power Sun Roof
* 38 - Not Used
* 39 - Circuit Breaker
Drivers Power Seat
* 40 - Circuit Breaker
Passengers Power Seat
RELAY PANEL LOCATION
The relay panel is located at the left corner of the instrument panel.
i copied this off a volvo site Hope this helps

Oct 10, 2016 | Volvo 850 Cars & Trucks

1 Answer

Malibu heating and ac


does the car have automatic climate control?

Apr 05, 2014 | 2005 Chevrolet Malibu

1 Answer

1995 chevy c1500 heater motor not working


Motor is working...?
If so. Need ground.


Mai Lor

Feb 26, 2013 | 1999 Chevrolet Silverado 1500

1 Answer

1993 Ford 3arus heater/ac blower not working.


Yes , it is possible that the motor or the speed control ahs failed so that the heat is not distributed. So what is needed is to check the fuse of the blower fan, if there is power to the fan motor and still it does not work then the motor can be faulty.

Dec 09, 2011 | 1993 Ford Taurus

1 Answer

I have a 1993 chevy 1500 the 4x4 wont engauge the shift lights wont come on . it use to take a few mins to kick in and now nothing , any good info


it could be the front axel actuator may not be working cause it sounds to me like it was weak but it could also be the locking sincer on the transfrercase

Aug 24, 2011 | 1993 Chevrolet K2500

1 Answer

Malfunctioning heating system, 2004 Chevy Silv


Blower fan only works in highest (#5) setting. Problem started a wek ago.

Sep 21, 2009 | 2004 Chevrolet Silverado 1500 Crew Cab

Not finding what you are looking for?
1993 Chevrolet C1500 Logo

Related Topics:

568 people viewed this question

Ask a Question

Usually answered in minutes!

Top Chevrolet Experts

yadayada
yadayada

Level 3 Expert

75117 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22095 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

7772 Answers

Are you a Chevrolet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...