Question about 1996 Chrysler Town & Country

1 Answer

My air conditioner air flow is very poor coming out of the vents.

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Legend:

    An expert who has written 200 answers of more than 400 characters.

  • Expert
  • 251 Answers

A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner, the first thing to check is whether the unit is getting proper power. If the unit uses 220 volt power be sure that the proper voltage is getting to the unit. Same for 110 volt units. A voltage meter can be used to assure that the voltage is correct.

For window air conditioning units the voltage can also be checked before and after the thermostat. If voltage is being supplied to the thermostat but not from it then the thermostat probably needs replaced. This is a fairly common problem. Another place to check is the fan motor voltage. The fan on window air conditioners runs both the indoor blower and the condenser fan. If that motor fails than the compressor may run for a short time, but will overheat and shut off. Continued operation like this will result in compressor failure. This motor can be economically replaced for larger window air conditioners, but for smaller ones the cost of replacement will be more than a new unit.

Central air conditioners for the home are more complex and there are more things that can go wrong. As with the window air conditioner the thermostat can also be a problem. The central air conditioner thermostat will only have 24 volts going to it. So don't look for high voltage there. Some units the voltage will be coming from the outdoor unit and others the voltage will be supplied by the indoor air handler or furnace. Most home central air conditioning will be supplied by the indoor air handler or the furnace. If the air conditioner is for cooling only the unit will usually have only two wires going to the condenser unit. Make sure that you have 24 volts across those wires.

The next thing to check will be the indoor blower. If your thermostat is calling for cooling then the indoor blower should be running. If there is no air moving across the indoor cooling coil then you will soon have a big block of ice formed on the coil. This can happen for a few reasons. The indoor blower is not working, the air flow is restricted and not allowing air to move across the coil. A clogged air filter would also do this. Or the outdoor condenser unit has lost the charge of refrigerant.

Finally and worst of all is when you have a complete compressor failure. Often when this happens the compressor will "lock up" or not be able to turn when power is supplied to it. Overheating or lack of lubrication are usually the main causes of compressor failure. Overheating can be caused by the outdoor coil around the compressor getting clogged with dirt, leaves, or grass. Loss of the refrigerant charge will also cause the compressor to overheat. It is the cool return gas coming back to the compressor that helps to keep it from overheating.

As you can see there are many things that can go wrong with an air conditioner and I have not come close to exhausting the possibilities here. I have just touched on the most common problems in a very basic way.
There are some basic trouble shooting things that can be done very easily. Most problems are above out of the range of comfort for many homeowners and professional help should be consulted before any attempt is made at repairs. Remember also, that the release of refrigerant gases into the atmosphere is a federal offense in the
US. Proper care must always be taken to minimize the release of any gases. A license is also required to handle refrigerants. Make sure that the professional you call has the proper certifications to handle refrigerants properly.


http://www.fixya.com/support/r3636709-size_air_conditioner_need

http://www.fixya.com/support/r3623253-window_air_conditioners_clean_every_year

http://www.fixya.com/support/r3633369-portable_air_conditioning_great_portable

http://www.fixya.com/support/r3623166-heating_air_conditioning_scams

http://www.fixya.com/support/r3597468-you_can_add_air_conditioning_to_your_hot

http://www.fixya.com/support/r3583697-how_to_keep_house_cool_without_using_air

Posted on Jun 07, 2011

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

1996 buick park ave ultra- air conditioner turns on but now air flows through the vents it was working fine! and all of a sudden it stoped


I answered this in a different question but I was assuming the air was not coming out of the right vent.
If the air is not blowing at all, you need to check for voltage at the blower fuse, the blower motor, and the resistor.
If there were a blockage such as a dirty cabin air filter, you should hear the blower running.

Jul 17, 2012 | Cars & Trucks

1 Answer

Poor Air Flow through the air condtioner


The procedure to check this filter and replace it is the same for the Express as the pickup truck. Please go to this LINK for instructions.

Feb 24, 2012 | 2002 Chevrolet Express

1 Answer

When i turn the air on it doesn't flow from the front vents.


Sounds like the switch or actuator is not operating. Some vehicles have mechanical operators, and some have vacuum actuators. If a vacuum line is loose, it will not actuate.

Aug 01, 2010 | 2004 Ford Explorer

1 Answer

Blown air system not working


May have stopped up cabin filter

Aug 05, 2009 | 2005 Kia Sportage

1 Answer

Air conditioner flow problem


MOST OF THE TIME THIS IS A VACUME ISSUE BROKEN HOSE ETC . POSSIBLE BLEND DOOR ISSUE, WOULD NEED TO TAKE TO A QUALIFIED TECH SHOULD NOT BE EXPENSIVE

Jul 21, 2009 | 2005 Chrysler Pacifica

1 Answer

Poor air flow from floor vents or when multiple vents choosen


There has to be something blocking the output somewhere. Check where vents come out to see if something has fallen down to block them.

Dec 05, 2008 | 2006 Honda Accord

1 Answer

Very low air flow through vents despite the fan working well


It is very likely that the Air conditioner evaporator core is restricted due to leaves or some other object may be blocking air flow like a plastic bag, does it do this on both outside air and recirculation setting?

Nov 29, 2008 | 1991 Oldsmobile Cutlass Supreme

2 Answers

No dashboard heat output


The climate control was poorly designed on these cars.

There is only heat on the floor and defrost settings, due to the layout of the ductwork.

Oct 22, 2008 | 1989 Ford Festiva

2 Answers

Air conditioner blower


I found the vac lin broke under the battery

Jul 29, 2008 | 1997 Buick LeSabre

Not finding what you are looking for?
1996 Chrysler Town & Country Logo

91 people viewed this question

Ask a Question

Usually answered in minutes!

Top Chrysler Experts

yadayada
yadayada

Level 3 Expert

76164 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

8273 Answers

Are you a Chrysler Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...