I changed the battery on 2006 Trailblazer SS. Now I can only get AC from my windshield and floor vents. Nothing from the dash vents. Also the temp control only gives coldest temp. I have checked fuses and all look good. Any advise?

Posted by on

Ad

2 Answers

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Expert
  • 38 Answers

Once you disconnect the battery your body control module loses power and memory you have to get some one with a scanner with reprogramming capabilities and have the computers reset ,dealer?

Posted on Aug 05, 2010

Ad
  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Chevrolet Master
  • 6,826 Answers

Air Door Actuators
Removal & Installation Console Mode To Remove:

  1. Remove the center console from the vehicle.
  2. Detach the air outlet duct from the center console.
  3. Disconnect the console mode actuator connector.
  4. Detach the console mode actuator from the center console.
To Install:
  1. Attach the console mode actuator to the center console. Torque the screws to 17 in-lb (1.9 Nm).
  2. Connect the console mode actuator connector.
  3. Attach the air outlet duct to the center console. Torque the screw to 17 in-lb (1.9 Nm).
  4. Install the center console into the vehicle.
Left Side Air Temperature To Remove:
  1. Remove the instrument panel carrier from the instrument panel.
  2. Disconnect the left side air temperature actuator connector. HVAC control module - left side I changed the battery on - gm-10-00-1844.gif

  3. Detach the left side air temperature actuator from the HVAC module.
To Install:
  1. Attach the left side air temperature actuator to the HVAC module. Torque the screw to 17 in-lb (1.9 Nm).
  2. Connect the left side air temperature actuator connector.
  3. Install the instrument panel carrier onto the instrument panel.
  4. Recalibrate the left side air temperature actuator.
Right Side Air Temperature To Remove:
  1. Remove the instrument panel carrier from the instrument panel.
  2. Disconnect the right side air temperature actuator connector.
  3. Detach the right side air temperature actuator from the HVAC module.
To Install:
  1. Attach the right side air temperature actuator to the HVAC module. Torque the screw to 17 in-lb (1.9 Nm).
  2. Connect the left side air temperature actuator connector.
  3. Install the instrument panel carrier onto the instrument panel.
  4. Recalibrate the right side air temperature actuator.
Mode To Remove:
  1. Remove the left floor duct from under the instrument panel (I/P).
  2. Disconnect the mode actuator connector. HVAC control module - left side gm-10-00-1844.gif

  3. Detach the mode actuator from the HVAC module.
To Install:
  1. If installing a new mode actuator, move the mode door to the middle position.
  2. Attach the mode actuator to the HVAC module. Torque the screw to 17 in-lb (1.9 Nm).
  3. Connect the mode actuator connector.
  4. Install the left floor duct under the instrument panel (I/P).
  5. Recalibrate the mode actuator.
Defrost Valve To Remove:
  1. Remove the instrument panel carrier from the instrument panel.
  2. Disconnect the defrost valve actuator connector. HVAC control module - left side gm-10-00-1844.gif

  3. Detach the defrost valve actuator from the HVAC module.
To Install:
  1. Attach the defrost valve actuator to the HVAC module. Torque the screw to 17 in-lb (1.9 Nm).
  2. Connect the defrost valve actuator connector.
  3. Install the instrument panel carrier onto the instrument panel.
Recirculation To Remove:
  1. Remove the HVAC module from the instrument panel.
  2. Detach the air inlet assembly from the HVAC module. Recirculation actuator removal and installation

  3. Disconnect the recirculation actuator connector.
  4. Detach the recirculation actuator from the HVAC module.
To Install:
  1. Attach the recirculation actuator to the HVAC module. Torque the screw to 17 in-lb (1.9 Nm).
  2. Attach the air inlet assembly to the HVAC module. Torque the screw to 17 in-lb (1.9 Nm).
  3. Connect the recirculation actuator connector.
  4. Install the HVAC module into the instrument panel.
  5. Recalibrate the recirculation actuator.

Posted on Aug 05, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Chevy climate control


it sure could be that head unit. if you want to clean the unit it might help. disconnect the battery, pop the bezel off the radio and head unit remove the four 9/32" bolts that hold the unit in the dash, unplug the head unit and spray it with computer duster.

Apr 03, 2014 | 2005 Chevrolet Malibu

1 Answer

Air blend door actuator


Possible bad blend door actuator .some gm cars can be relearned to the new climate control head

Jul 28, 2013 | 2001 Oldsmobile Aurora

1 Answer

AC issues


The problem is either an actuator or the door associated with it. Sometimes the gear strips, especially when the system goes thru a recalibrate after power has been removed and reapplied. Below is a diagram of the locations of the actuators.



9_9_2012_12_22_41_am.jpg

Sep 07, 2012 | 2002 Chevrolet TrailBlazer

1 Answer

AC works fine at first then stops blowing thru dash vents and will only blow thru defrost and floor vents. this is an 02 chevy trailblazer. It this an expensive thing to fix?


It's most likely a vacuum line, look under your hood (close to the cowl panel) for a disconnected, cracked or broken vacuum line.

In some rear cases, it could be the vacuum switch (in dash). Or vacuum diaphragm (under dash).

Hope this helps you ???

Jun 21, 2011 | 2002 Chevrolet TrailBlazer

2 Answers

AC doesn't blow from dash vents.Blower will not switch from floor position.


NEED TO HAVE YOUR TEMP CONTROL UNIT CHECK FIRST. ONE OF THE VENT DOORS ARE NOT OPENING UP

Sep 27, 2010 | 2006 Chevrolet Trailblazer

1 Answer

The heater / ac control only works with one or two desired settings.defrost will not work at all (2006 chevy trailblazer)


The actuator motor that controls the defrost,to floor,to vent ,has gone out,this will be a job to take to the shop,the dash will have to be pulled out toward the seats to replace the actuator motor.

Jan 21, 2010 | 2006 Chevrolet Trailblazer

1 Answer

Fan forced air trouble in a 2005 Focus


it could be a vaccum line thats disconnected or the bypass vent door that diverts the air is either stuck or broken.

Sep 16, 2009 | 2005 Ford Focus

2 Answers

2006 trailblazer ls v6- A/C only blows on the floor & windshield, not from dashboard. A/C is cold, all fan speeds work. I replaced the relay & 40A fuse in the underhood fuse box, the fuses looked...


sounds like it might be a blend door motor, It is located on the drivers side up under the dash on the side of the heater box, try looking at it while turning the knobs on the dash and see if it is changing positions, if not than the blend door motor might be the problem

Jun 17, 2009 | 2006 Chevrolet Trailblazer Ext

1 Answer

Vent from ac/heater will not change from top exhaust port


two issues here. bad servo motor maybe and, jammed lever assembly. i would also check the wire connections for lose and separated connections.


please rate and god bless.

Mar 16, 2009 | 2006 Ford F 350 Super Duty

1 Answer

2005 trailblazer dash vents not working


CHECK TO SEE IF A VACCUM LINE DISCONECTED SOME HOW. OR YOU CAN CHECK BEHIND GLOVE BOX TO SEE IF VACCUM DOOR IS OPERATERING PROPERLY,NOT SURE IF IT IS THE SAME AS A 2003 S-10 BLAZER.

Oct 26, 2008 | 2003 Chevrolet Blazer

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

1,359 people viewed this question

Ask a Question

Usually answered in minutes!

Top Chevrolet Experts

yadayada
yadayada

Level 3 Expert

76164 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

8273 Answers

Are you a Chevrolet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...