Question about 2005 Ford Explorer

1 Answer

Defroster does not work. Only A/C/Heat from front vents, even when set to defrost. Suspected panel/defrost Door Bend Actuator. Any suggestions?

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Ford Master
  • 6,826 Answers

Yes, it sounds like a blend door actuator problem.


By Jeff Frank First you have to remove the glove box to gain access to the plenum. Next, remove the actuator from the box. The actuator is a flat white box that sits on 4 clip posts on the top-left of the plenum. It has a wire harness coming out of it. To remove it take a flat screw driver and pry up the front first then put the screw driver under and towards the back to pop up the back. You will see a white pin coming out of the bottom of the actuator. The pin is "D" shaped. Turn the ignition on and move the heat control and you should see the pin rotate. If not, the actuator is bad or the terminals are corroded. If it does move, set the control to full heat and turn the blower on high. This will force the blend door into the heat position (it is very important to do this).
Take a small dentist mirror and a flashlight and look into the top of the box where the actuator pin goes in. You should see that the chamber is half missing. It should look like the drawing below:
Defroster does not work. - 1-1.gif I think they all break in the same spot. Mine was in the position as the one above. Remember you are looking through a mirror so it is a little difficult to determine the exact position. If yours looks like mine did drill your actuator pin in the same place I did. If not, try and gauge where yours will need to go. I had to drill mine four times before I got the right position. I drilled mine with a very small drill bit. If you are looking at the pin from it's bottom, this is where it should be drilled: (drill about 1/2 inch from the bottom)
1-2.gif After drilling the actuator pin hole, you will need something to put through it. I used an old drill bit that was the same size as the hole. Just cut it to length (you will want a little more than 1/8th inch on either side of the pin). Put the rod through the pin (it should be snug so that it doesn't fall out). Then try snapping the actuator back on the box. If the pin won't go in fully the rod might be in the wrong place. Try turning the blower on high again to make sure the door didn't move and try again. If it still won't go in you will have to re-drill the hole. If it does go in, try the heat controls. If they work, congratualtions! Now take the actuator back out and glue the rod in place and put the actuator back on. You just saved yourself $1000. If only the cold or heat works, then either the rod is in the wrong position and will need to be re-drilled, or the door itself is also broken.

Posted on Aug 03, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My 1999 dodge dakota only blows out heat or A/c fom the defroster


Mode door actuator bad > electric motor that switches mode door from floor to vents to defrost ! Google mode door actuator for dodge Dakota ! Mite be a video on youtube showing how to fix it !

Dec 07, 2016 | 1999 Dodge Dakota

1 Answer

My air condition and heat works on defrost only sometime comes out vents last seconds didn't matter were controller set


Not sure what year, make or model vehicle is in question, but the issue is due to an actuator that has gone bad. Sometimes referred to as a mode actuator or blend door actuator. This actuator controls where air/heat will blow from (defroster vent, forward vents, floor vents or combo, etc.). Good luck. Ron @ Speed-O-Repair.

Aug 24, 2014 | Cars & Trucks

1 Answer

Heater only works on heat won't switch over to defroster or vents


Sounds like the blend door. The actuator motor is located on top of the box (behind the glove box) and is notorious for failing.

Oct 26, 2012 | 2004 GMC Sierra

1 Answer

The heat/vent/defrost control panel does not respond consistently. Specifically, pressing any of the buttons that is supposed to direct the airflow to heat/vent/defrost ports does nothing (the light for...


Check the actuator motor and rods on the heater box inside. The motor moves the doors in the heater to direct the heat to the area you request. It is a small motor on the driver side or in front of the heater above the dash.

May 11, 2017 | 1994 Buick LeSabre

2 Answers

When I turn my air conditioner on, the air blows out on the dashboard for the windshield and not from the vents. What can I do??


The blend door actuated by solenoids may not be working correctly causing a/c cool air to come out of the windshield vents, rather than the regular front vents.

Defroster Valve Actuator 1996 – 1999 1996 – 1999 HVAC Actuators gm-10-00-1840.gif

To Remove:
  1. Remove the air distributor assembly.
  2. Unclip the defroster valve actuator from the air inlet.
  3. Disconnect the defroster valve actuator from the valve.
To Install:
  1. Disconnect the defroster valve actuator from the valve.
  2. Clip the defroster valve actuator from the air inlet.
  3. Install the air distributor assembly.
Heater/Bi-Level Actuator 1996 – 1999 1996 – 1999 HVAC Actuators gm-10-00-1840.gif

To Remove:
  1. Remove the air distributor assembly.
  2. Remove the clip and the screws that fasten the 2 halves of the air distributor assembly and separate the air distributor assembly.
  3. Unclip and disconnect the heater/bi-level actuator from the valve.
To Install:
  1. Connect and clip the heater/bi-level actuator to the valve.
  2. Fasten the 2 halves of the air distributor assembly together and torque the fasteners to 13 in-lbs (1.5 Nm).
  3. Install the air distributor assembly.
---
Removal & Installation Recirculation Actuator 1996 – 1999 1996 – 1999 HVAC Actuators gm-10-00-1840.gif

To Remove:
  1. Remove the left sound insulator panel.
  2. Disconnect the vacuum hose from the recirculation actuator.
  3. Remove the recirculation actuator from the valve.
To Install:
  1. Connect the recirculation actuator to the valve.
  2. Clip the recirculation actuator to the air inlet.
  3. Connect the vacuum hose to the recirculation actuator.
  4. Install the left sound insulator panel.

Aug 13, 2010 | 1997 Buick LeSabre

1 Answer

Ac blowing out defroster and heat vents only


There is a vent door actuator motor that is not working in the dash,the dash will have to be removed to access the actuator motor

Jun 13, 2010 | 2001 Ford Taurus

1 Answer

Front dash vents


check the vacuum switch,,and the temp door actuator motor

Jul 06, 2009 | 1999 Chevrolet Astro

Not finding what you are looking for?
2005 Ford Explorer Logo

993 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

76132 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

fordexpert

Level 3 Expert

5520 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...