There is no power to my heater blower motor in my 1998 Ford Taurus SE with V6 engine. Fuse is good What else should I check?

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Ford Master
  • 17,970 Answers

Check the fuse first; refer to the Owners Manual for the fuse (position 13, 5AMP); according with your comment this fuse is OK.

If the blower is completely dead and is not providing any air movement, the cause could be in the resistor block for the fan motor or the fan motor.

1.- If you have one or more blower speeds, the problem is the Resistor Block. This part (resistor block) controls the various speeds of the blower motor. It is located on the passenger compartment side of the blower housing and can be replaced in few minutes. You can find the part online for around $10.

2.- If you do not have any speeds, you should verify the Fan Motor works by pulling it and connecting it to a 12 volt DC power source. To pull the fan motor, you will have to remove the glove box to gain access to the 3 or 4 screws that hold the fan in place, although I did it without removing the glove box. The motor is attached to a large mounting plate that is at the bottom of the air plenum located behind the glove box. If you look up from the passenger floor you will see the motor hanging down. Once the connector is disconnected and the screws are out, you will have to turn the mounting plate to allow the motor to drop. Keep in mind the position as you pull it down as it needs to go back in the same twisting fashion.

There is no power to - 2fc44db.jpg

Fig. 1: The blower motor-to-evaporator housing mounting


be3eeaa.jpg

Fig. 2: the blower wheel is held to the motor by a retaining clip

If the motor is good and really spins up, then the problem is the resistor block is completely dead (replace it the resistor block)


Hope help with this.


Posted on May 13, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Where is my ign fuse located on my car


Below dash instrument panel, R16 ignition relay
98 Ford Contour SE Fuse Box Map
Fuse Panel Layout Diagram Parts: passenger side air bag, heater blower, interior lighting, heater blower motor, parking lamp, interior lighting, electric mirror, clock, wiper motor, ignition, reverse voltage protection, rear window defrost, engine management system, instrument panel illumination, radio, wiper motor, power windows, ABS module, backup lamp, brake lamp, door lock, main light, cigar lighter, electric seats,
link below should be the same as yours, press the helpful button

http://www.autofuseboxdiagram.com/1342-98-ford-contour-se-fuse-box-diagram

Jan 30, 2016 | 1999 Ford Contour

1 Answer

Where is my ign fuse located on car


Below dash instrument panel, R16 ignition relay
98 Ford Contour SE Fuse Box Map
Fuse Panel Layout Diagram Parts: passenger side air bag, heater blower, interior lighting, heater blower motor, parking lamp, interior lighting, electric mirror, clock, wiper motor, ignition, reverse voltage protection, rear window defrost, engine management system, instrument panel illumination, radio, wiper motor, power windows, ABS module, backup lamp, brake lamp, door lock, main light, cigar lighter, electric seats,
link below should be the same as yours, press the helpful button

http://www.autofuseboxdiagram.com/1342-98-ford-contour-se-fuse-box-diagram

Jan 30, 2016 | Cars & Trucks

1 Answer

On my 1998 Ford Torus how do you fix the heater and keep the heater from blowing fuses.


sounds like the blower motor is bad..its pulling to many amps to to run this blows the fuse.. replace blower motor.

Nov 24, 2014 | 1998 Ford Taurus

2 Answers

1998 ford taurus se windshield wipers don't work


first you have to check if the motor has power. get a tester and test for power on the motor. if you are not getting power check a fuse, is you are getting power but the motor is not working then you may have to change it.

May 07, 2014 | 1990 Ford Taurus

2 Answers

Diagram of engine compartment fuse/ relay box 1999 ford taurus se


40A fuse 11 in the battery junction box feeds power to the blower motor relay via a BRN/ORG wire

Oct 27, 2012 | 1999 Ford Taurus

1 Answer

2000 escort diesel van.interior heater has stopped working,checked fuse and its not that.any ideas ? any thoughts.cheers


likely your blower motor. but take connector off at blower, key on, htr on high. should have power at connector. check with a test light. If power is present, its your blower. If no power, and fuse is good, it's a wiring issue or your heater blower switch on the dash.

Oct 17, 2011 | 1998 Ford Escort

2 Answers

98 Ford Taurus SE needs water constantly, could


could be a leaking head gasket but the heater sounds like its air locked have the head gasket checked

Apr 02, 2010 | 1998 Ford Taurus

1 Answer

Which fuse operates the ac & heater blower on a 2001 ford Taurus. Box is under the hood with many empty socket and no diagram.


There is a fuse box inside the car to the left of the steering column. fuse 228 10 amp and fuse 208 40 amp. Check power to the blower motor connector. Check for water in blower. I have seen water get into blower motor and short out. Good luck I hope this helps.

Jul 30, 2009 | 2001 Ford Taurus

1 Answer

1998 ford taurus blower won't work. Heat won't go on or the a.c. How can this be fixed or what is the cause of the problem?


Check the fuse box under the hood and look for the a/c heater blower fuse, check to see if it's gone bad and needs to be replaced. The other thing to is check if the blower fan works on high setting only, if it does, then the blower motor resistor has gone bad and needs to be replaced. Once you have gone through all the electrical fuse and relay, then good chance that the blower motor needs to be replaced. If you go to Auto Zone they will have the blower motor and resistor if you want to replace that too and they will have the step by step instructions for you to get the job done with common tools. Good luck and keep me posted, be glad to answer more questions you may have. 

Jul 01, 2009 | 1999 Ford Taurus

3 Answers

Blower on the heater/AC not working on 1998 Escort, checked fuse under dash?


Ok, first off, check the fuses under the dash. If they're all good, does the blower work only on high speed? If yes, then you have a bad blower motor resistor, which is located under the hood, near the blower motor itself. If the motor doesnt work at all at any fan speed, make sure the wiring harness that plugs into the motor under the hood is clean and tightly installed. If it still doesnt operate, sometimes tapping on the blower motor housing will kick it on, but if that doesnt work, you may have to replace the blower motor. They are available aftermarket, and arent usually too expensive.

May 24, 2009 | 1998 Ford Escort

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

69 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

75822 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

fordexpert

Level 3 Expert

5501 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...