    How do I test the resistors?

  • huge5550 May 14, 2010

    to fix this problem i had to replace the blower motor resistor which is located right next to the blower motor itself. Cost from dealer was $45 + tax.

×

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Master
  • 1,374 Answers

This could be the on/off switch, an open in the circuit,a defective relay,resistors, or blower motor itself.

Posted on May 13, 2010

  • JIMMY May 14, 2010

    Each resistor represents a speed. You need the shop manual and a Digital Voltmeter(DVM) to do this. Your basically measuring the resistance of each resistor with the meter to see if their resistance is within spec's or infinity. The shop manual will tell you what each resistors values are.

    BUTin your case its not comming on at all I would make sure it works first. Make A SET OF JUMPER CABLES AND HIT THE BLOWER MOTOR ITSELF WOTH DIRECT B+ FROM THE BATTERY. iF THE MOTOR WORKS THEN ITS THE SWITCH OR THE RELAY. REMEMBER HIGH SPEED BYPASSES THE RESISTORS AND IS DIRECT B+ FROM BATTERY. HINT IF HIGH SPEED ON SWITCH DOESN'T WORK!!!!!!!! Is it the switch or the motor?BuT MAKE SURE MOTOR IS GETTING B+ Eliminate the motor as being the culprit first then concentrate on the switch and relay.

  • JIMMY May 16, 2010

    Glad I could help . You saved yourself a bundle.

×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

3 Answers

I have new blower motor. it dosen't stop running


Could be a bad blower motor resistor,mounted by the blower.

Sep 28, 2016 | 2002 Dodge Ram Pickup 1500

1 Answer

Want to change fan on blower heater


Removal

  1. Remove wiper arms.
  2. Remove cowl panel.
  3. Disconnect blower motor electrical connector and vent tube.
  4. Remove blower motor retaining screws.


  1. Remove fan retaining nut from blower shaft through plenum opening while holding the fan from the engine compartment.
  2. Remove fan from blower motor while removing blower motor from vehicle.
Installation

  1. Hold fan through plenum opening.
  2. Install blower motor to vehicle while installing fan to blower motor.
  3. Install fan retaining nut to blower motor shaft through plenum opening.
  4. Install blower motor retaining screws.
  5. Connect electrical connector and vent tube.
  6. Install cowl panel.
  7. Install wiper arms.

Aug 13, 2013 | 1991 Oldsmobile Cutlass Ciera

2 Answers

Honda pilot 2007 blower fan making noise blower fan was replaced once still making noise


Either its developed the same fault or the fan motor bearing has failed, needs greasing or, if there's a belt, the belt is slipping.

Feb 22, 2012 | 2008 Honda Pilot

2 Answers

01 grand.prix ac fan switch only works on high. has a duel temp controller when you turn fan off the only way fan comes back on is to move the temp controller levers


Hi!!
When the Blower Motor Resistor (controls blower speeds) goes bad, the blower motor works only on HIGH SPEED. REPLACE IT.
BLOWER MOTOR RESISTOR Removal & Installation
  • Disconnect negative battery cable.
  • Remove right lower instrument panel insulator panel.
  • Disconnect blower resistor connector located behind right side of dash.
  • Remove blower resistor screws and blower resistor.
To install, reverse removal procedure
Good Luck!! A HELPFUL - 4 THUMBS - rating for this solution would be greatly appreciated. Thank you for using FixYa!!

Feb 18, 2011 | 2001 Pontiac Grand Prix

2 Answers

Heater blower stopped working?


Hello,
You may want to try your fan on all speeds. If it will work on high, you have a bad resistor for the fan motor. ( high speed doesn't go through the resistor ).
If it doesn't work on any speed, I would check the following;
1. Make sure the fuse isn't blown for the fan blower motor.
2. Check, or have checked the wires between the fan control switch and the fan blower motor.
3. Have the fan control switch checked.
4. Have the fan blower motor checked.

I hope this helps you.

Feb 03, 2011 | 2002 Buick Rendezvous

2 Answers

2005 Chevrolet Silverado - Fan not coming on. When I turn the heater/ac blower fan on, fan does not work. Prior to completely going out, fan would quit working intermittently. Is this a fuse problem? ...


Chk for power at the blower motor electrical connector. If no voltage, check the blower motor resistor, its within the blower motor vent (this controls power to the blower motor). Also, in theses vehicles water may have damaged the blower motor itself. Inspect the blower motor for proper function.

Aug 10, 2010 | 2005 Chevrolet Silverado 1500HD

1 Answer

Need location on blower motor resistor on 1994 pontiac bonneville


58f261e.jpg

Fig. 1: The blower motor and fan assembly is mounted in the heater and A/C module, and is accessible from the engine compartment

GM Bonneville/Eighty Eight/LeSabre 1986-1999
Blower Motor - REMOVAL & INSTALLATION
(see Figures 1 and 2)
  1. Disconnect the negative battery cable.
  2. If necessary, tag and disconnect the number 2, 4 and 6 spark plug wires from the ignition coil and move the coil out of the way.
  3. For 1993-99 vehicles, remove the nuts and cross brace bar.
  4. Detach the electrical connections from the blower motor.
  5. Disconnect the cooling tube from the blower motor.
  6. Unfasten the screws securing the blower motor to the blower module assembly.
  7. Remove the blower motor and fan assembly from the module.
  8. If necessary, unfasten the nut attaching the fan to the blower motor shaft, then pull the fan from the blower motor.
68515cf.jpg

Fig. 2: You can disassemble the fan from the motor by removing the retaining nut


To install:
  1. If the fan was removed from the motor, position the fan on the shaft, then install the retaining nut. Tighten the nut to 12 inch lbs. (1.4 Nm).
  2. Position the blower motor and fan assembly to the module, then install the retaining screws. Tighten to 5 inch lbs. (0.6 Nm).
  3. Connect the cooling tube to the blower motor.
  4. Attach the electrical connector to the blower motor.
  5. On 1993-98 vehicles, install the cross brace bar and retaining nuts. Tighten the nuts to 18 ft. lbs. (25 Nm).
  6. If removed, install the coil and connect the spark plug wires, as tagged during removal.
  7. Connect the negative battery cable.

Hope this helped (remember rated and comment this).

Mar 26, 2010 | 1994 Pontiac Bonneville

1 Answer

Saturn 2000 LS2 Blower Fan Problem


You blower fan obviously works. Try replacing the fan speed switch.

Mar 17, 2009 | 2000 Saturn Ls 4dr Sedan

Not finding what you are looking for?
2000 Acura TL Logo

Related Topics:

261 people viewed this question

Ask a Question

Usually answered in minutes!

Top Acura Experts

yadayada
yadayada

Level 3 Expert

76070 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

8266 Answers

Are you an Acura Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...