Question about 2002 Ford SVT Focus

1 Answer

Blower on fan not working on 1/2/3 but working on 4

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 678 Answers

The most likely cause is a bad blower resistor. The resistor is behind the glove box. Open the glove box and remove it's contents. Gently squeeze the sides of the glove box and pull it down. The resistor is blue i believe. Disconnect it and remove the screw securing it. Installation is the opposite of removal. You can get the resistor pack from the dealer for about $20.

Posted on May 09, 2010

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Repair of A/C and heater fan not working


1998 JK jeep , ive posted these tests and the free FSM book here, 100s of time.s
search much?
its the heater blower. failing.
DOES IT BLOW ON HIGH?????????? this is #1 important.
and like all such blowers, it can fail for all these ways.
even a loose wire.
1: fuse blown, (always first, for the end of time)
2: controls bad.
3: blower bad.
4: wire to any of the above, bad. (not conducting or shorted)
all cars,. some newer cars a computer runs this but is #2




the book is free.
98jx
click (spoon fed) JK 96+
click wiring
click 8w2-1 index. then see heater. blower.
blower is page 8w42 in the real fsm
what does it show.?
JB25 fuse not blown? (answring for fan dead no high)
Relay works>? tests, like all relays we test. sop
gas engine?
Fuse PDC6 not blown if diesel PDC 11
on HIGH the lever blower , on high grounds the motor blower
if the relay has power to blower 12v pin A ,dark green
then the blower motor is bad.
it only takes a $10 walfart meter to find cause.
12vdc across the blower pins on high is goal.

here is the free book, and is REAL not some PoS clone RAG.
http://www.morris4x4center.com/knowledge-base/index.htm?utm_source=cj#service

Sep 26, 2016 | 1998 Jeep Cherokee 4WD

1 Answer

Location of 2003 Honda accord blower motor


Check to see if u have power & ground to the blower with the fan on.if so u need A blower mtr

Aug 13, 2017 | 2003 Honda Accord

2 Answers

VW Golf 2000 A/C and Fan Blower problem


In most cases, the problem related to blower and A/C switch lies with the fan controller relay which is fitted on the housing of the blower. It is a small circuit board and your fan is connected through this circuit relay and it controls the speed of the fan which further due to safety circuit controls the A/C. indirectly. Check that.

Apr 14, 2012 | 2000 Volkswagen Golf

2 Answers

Heater blower stopped working?


Hello,
You may want to try your fan on all speeds. If it will work on high, you have a bad resistor for the fan motor. ( high speed doesn't go through the resistor ).
If it doesn't work on any speed, I would check the following;
1. Make sure the fuse isn't blown for the fan blower motor.
2. Check, or have checked the wires between the fan control switch and the fan blower motor.
3. Have the fan control switch checked.
4. Have the fan blower motor checked.

I hope this helps you.

Feb 03, 2011 | 2002 Buick Rendezvous

1 Answer

Heater/defrost/ac does not blow in my 2006 tacoma. worked this morning, parked at work, came out half hour later and would not work.


what has most likely happened is that a fuse has blown that is in your blower fan circuit. Check your owners manual, and see if there is a fuse to that system, if there is, check and see if it is blown. If it isn't, then the problem could either be your blower fan itself, or your blower motor resistor. Generally, when the blower fan goes bad, no speeds of the fan work. When the Blower motor resistor goes bad, usually only 1 speed of the fan works. Try the first suggestion i gave, and it everything checks out in the fuse box, then try all of your fan speeds. If one works, you need a blower motor resistor, if none work, then it is most likely your fan. Let me know how it goes and i'll do my best to assist you further. good luck.

Jan 13, 2011 | 2006 Toyota Tacoma

1 Answer

2004 sierra, fan blower stopped, not the fuses. where is the fan blower switch and how do I replace


get a voltmeter; check for 12vdc at the blower motor with the blower turned on; if there is voltage, the blower motor is bad; should be located behind a panel underneath the dash on the passenger side; if the fan works on 1 or 2 speeds, it is probably the blower resistor located in the same area as the blower; u can check utube for details

Jun 27, 2010 | 2004 GMC Sierra 1500 Crew Cab

1 Answer

Where is the fan in a 2000 dodge caravan


I am assuming you are asking about the Blower Fan and not the Radiator Fan?
The Blower Fan is located below the Passenger side Dash. It is inside the black Duct work.
May I ask what the problem is?
Is the Blower working or only working on High? If only on High then the Blower Motor is fine and the Blower Motor Resistor that controls the Low to High speeds is bad. This is located behind the Glove Box in the Dash and on the firewall. Remove the Glove Box to access. It is approximately 3 1/2 inches by 1 1/2 inches and has 3 to 4 wires going into it.
There is also a Front Blower Motor Relay located in the Relays and Fuses.
Before replacing the Blower Motor, get back with me (for free) and let me know. This may save you alot of money in the long run, saving you from purchasing parts you may not need!
Let me know if this helped, and let me know what the problems (symptoms/signs) are.
Contact me in the Comment Section of your Posted problem.

Feb 02, 2010 | 2000 Dodge Caravan

1 Answer

My blower fan only works on high


you will need to order a blower resister its easy to swap out

Dec 11, 2009 | 2000 GMC Sierra

2 Answers

Heater blower is not working in 1, 2, 3 and fan


MY 2003 MALIBU AC WORK VERY COOL FOR ABOUT ONE HOUR AND THEN TURN A BIT HOT AND THEN NO AIR COME OUT WHY I HAVE CHECK THE FREON AND ITS OK .

Nov 22, 2009 | 2003 Chevrolet Malibu

2 Answers

Blower fan resistor module replaced, worked for 2 days quit again


HIGH RESISTANCE IN THE BLOWER MOTOR CAN CAUSE YOUR PROBLEM, OR A BAD RESISTOR.
THERE IS NO REAL GOOD WAY TO CHECK THE RESISTANCE OF THE BLOWER MOTOR.

Jul 16, 2009 | 2005 Chevrolet Malibu

Not finding what you are looking for?
2002 Ford SVT Focus Logo

Related Topics:

81 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

75797 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22114 Answers

fordexpert

Level 3 Expert

5495 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...