1 Answer

A couple months ago I had water draining onto the pasenger compartment floor below the blower motor. Recently the blower motor stopped working? Do you know what parts I may need?

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 101 Answers

The water leaking issue may have cause the blower operation issue. there is a drain for the a/c housing that comes out at the bottom side of the firewall on the passenger side of the vehicle under the hood that likes to clog up and build water in the housing. the water then runs into the blower motor causing corrosion in the motor and usually the connector at the blower melts as well. the blower is easy to change, the connector is not as easy but shouldn't be too bad. the blower can be found just under the glove box and has a 2 wire connector

Posted on Dec 10, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

1995 Pontiac Grand AM SE. Heater fan works for weeks then won't go, try a couple hours later then it goes.


It sounds like the brushes on armature for (blower motor ) are worn. Sometime a bad spot on the armature from not being used often and also by being in the engine compartment where it is exposed to condensation. When the brushes stop at that particular spot, the blower will not start spin process unless it draws alot of current that may be why the fuse blew. You can remove the blower and examine or just make the change.

Jan 28, 2013 | 1995 Pontiac Grand Am

1 Answer

My front blower motot is no longer working on my 2010 dodge grand caravan


You need to clear the water drain for the blower motor housing, and replace the blower motor is my guess here. Remove the blower motor and check the bottom of the housing it sits inside, there is a hole there, it will be blocked with leaves or other detritus like mouse nests. Use a coat hangar or any thick wire to clear it. Once clean the water problem will go away. As far as the blower goes next time it won';t work hot the end of it with a pieces of wood and see if it starts, if it does then the blower motor is defective. The blower motor is under the dash on the passenger side,.

Nov 01, 2012 | 2010 Dodge Grand Caravan

1 Answer

Blower motor need a page from the book to fix it and it location


Component

Blower Motor Below right side oft?

Blower Motor Relay . In engine compartment fuse relay box

Blower Motor Resistors Below right side oft?

Blower Switch Below center oft?

Engine Compartment Fuse Relay Box Left side of engine compartment

ignition Switch Below left side oft?

Cl90 (68-LT gry) Left side of engine compartment (fuse relay box)

C20l (20-W HT) Below left side oft'?

C225 (13-Will) Below right side oft'?

Q216(8-WHT) Below right side ofi?

0203 Below left side oft'?

Blower Removal

1. Discharge the refrigerant from AC system. (Refer to the operating instructions of

your refrigerant recovery recycling charging station for proper procedures.)

2. Disconnect the inlet and outlet pipe from the evaporator.

NOTICE

- When connecting and disconnecting, refer to Quick Coupling below

- Immediately plug all open fittings to keep moisture out of system.

3. Remove the cover and drain hose.

4. Remove the glove box and disconnect the wiring harness connector.

5. Remove the blower unit.

6. Install in the reverse order of removal.

7. Evacuate the refrigerant system. (Refer to the operating instructions of your

refrigerant recovered cycling charging station for proper procedures.)

S. Charge the AC system. (Refer to the operating instructions of your refrigerant

Recovery recycling charging station for proper procedures.)

leedavidian_160.jpgleedavidian_161.jpg

Dec 16, 2010 | 1998 Kia Sephia

1 Answer

Water under pasenger side carpet not from heater core


Find the drain for the A/C located under the hood, firewall, nearest the bottom of the firewall. It will be a black tube and if plugged, the condensation from use of the A/C (which also turns on when the defrost is used to evaporate moisture) will back up into the blower box and drain onto the floor. Long term effects include; rotted floor board, mildew, shorted blower motor and loss of effective defrosting, heating and cooling. Use a coat hanger or other long thin item to clear the drain and allow the water to drain. The system will be much more efficient. Let me know if you need anything else.

Nov 08, 2010 | 1999 GMC Jimmy

2 Answers

Blower will only work on high


Parts of your blower speed control reister are burnt out, replace the resister I believe it is mounted on the bulhead on the pasenger side accesible from the engine compartment.

Jan 14, 2010 | 2001 Dodge Caravan

1 Answer

AC drained into blower motor...replaced moter and now wont work


Did you check the blower motor before installation?Check for a blown fuse,and a bad relay,also check the blower motor resister.I hope this was some help.

Oct 05, 2009 | 2004 Mitsubishi Endeavor

2 Answers

In the past I have had major water leaks in my 2005 grand prix. I never knew wehre the water came from. Now, I can hear water under my car shifting whenever I turn a corner. Where is it coming from??


Do you have a sun roof? I imagine you do.

Under the roof cover there is a tube on each side of the car that drains the sunroof area to the ground. Either a tube has been disconnected or come loose. This will cause severe mold and mildew problems if not fixed soon.

Jun 06, 2009 | 2005 Pontiac Grand Prix

1 Answer

Water leaking in on pasenger side floor


It sounds like you may have pinched the 12 volt wire that supplies the blower motor with power, and the seal between the motor and housing is letting in water. Try removing the blower motor and look for the pinched wire where it may be short circuited, and reseal the motor to the housing with a new gasket or silicone sealer.

Sep 27, 2008 | 1999 Oldsmobile Intrigue

Not finding what you are looking for?
Cars & Trucks Logo

170 people viewed this question

Ask a Question

Usually answered in minutes!

Top Mitsubishi Experts

Marvin
Marvin

Level 3 Expert

81342 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22326 Answers

Jeffrey Turcotte
Jeffrey Turcotte

Level 3 Expert

8841 Answers

Are you a Mitsubishi Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...