Question about Cars & Trucks

1 Answer

Wont run when up right

Im working on this ryobi leaf blower at my high school it runns when its on its side but if you put it up right it die and if you dont have the tank about hafe full it dont run i think its something whit the fule line but dont know what

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 708 Answers

Check the position of the fuel line in the tank. if it is towards the backside of the tank, when you put it upright all the fuel will flow away from the hose and it may not be able to reach the fuel. When its on its sie the fuel is evenly disperesed in the tank so it can pick it up.

In other words, reposition the hose in the fuel tank.

Posted on Nov 18, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya Mechanic can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repair professionals here in the US.
click here to Talk to a Mechanic (only for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Heater blower stopped working


Check your fuse, then you need to know if your blower is blocked or sceized, leaf, ice, any rubish

Jan 13, 2014 | Cars & Trucks

1 Answer

Drove truck to school everything great, i leave school and it dies and try to get it going and it acts like its got water in my gas or something .it starts then it wont drive i took of fuel filter and...


Sounds like the fuel pump has gone out. Test fuel pressure to see. Think it needs about 45 to run right.

Most people take the bed off to replace pump. Don't but an Airtex.. Best to buy GM OEM. I know from having to do several Airtex's twice.

Sep 15, 2011 | 2003 Chevrolet Silverado 1500

3 Answers

My lower fan speed don't work except for the high, the fan high speed stay highest


Hello sanjuis24
It sounds like you've got a bad blower motor resistor. The resistor is located under the right side of
the dash at the blower motor. A new resistor is not very expensive and it's a fairly easy DIY.
Hope this is helpful

Mar 07, 2011 | 2003 Chevrolet TrailBlazer

1 Answer

My Dad's 1985 Ford F150 Died on him yesterday. He says it started running rough like it was runnning out of gas but he thinks there is about 50 miles left in his tank(s) (his gas guage is broke so he...


Yes there are two fuel pumps of there are two fuel tanks.
One in each tank.
I assume you tried both tanks?
Best way to diagnose, put fuel in both tanks, and check each one.
The fuel pump relay in under the hood on the relay bank driver side fender.
You can provide power there on the lug going to the fuel pump. So, make sure the tank selector is working properly by setting the selector on the left tank, then turning the key to on, you should hear the pump come on for a couple seconds. Then do the same for the right tank. You need to make sure that the same pump is not coming on. Listen to each side. If that works, then the relay is OK too, and you have ruled out the pumps. Then check the valve that switches the tanks, see if there is any debris in it, or if it is even switching tanks.

Also check your fuel pressure at the fuel injector rail.

Oct 04, 2010 | 1985 Ford F150

2 Answers

2000 grand prix blower motor only worked on high for awhile now it doesnt work at all


in alot of cases the blower motor resistor burns
if you follow the blower connection to left you will the resistor plugs right in to the blower but make sure you check it before you buy it take it off and inspect it you will see burns on harness and resistor
its under the passiger side dashboard you will see the blower and to the left is the resistor i think you will need a 9/32 socket or 7mm its held by one screw
good luck

May 22, 2010 | 2000 Pontiac Grand Prix

2 Answers

Ok again. forget what money i put into it. Right


I dont know if this may help or not but 87-91 jeeps had bulhead and wiring problems at the firewall area,
also had distributor and computer problems. relays were also a problem with tese vehicles. Good luck with your problem

Oct 01, 2009 | Jeep Cherokee Cars & Trucks

1 Answer

Blower motor wont work


Disconnect connector at blower under pass side of dash.Check for power & ground with the blower switch in the #4 speed (High).Most Likely a blower motor if all 4 speeds are out.If high works but no other speeds,you need a blower resistor.Blower easy to change 3 screws & one connector.hope this helps

May 19, 2009 | 1993 Saturn SL2

1 Answer

My car wont stay running


it could be the fuel pump not working right. you can buy an electric one and put on there and it will tell you right away if your original fuel pump is dead

Dec 29, 2008 | 2001 Volkswagen Beetle

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

29 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cars & Trucks Experts

yadayada
yadayada

Level 3 Expert

77169 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22265 Answers

Randy Ohler

Level 3 Expert

14585 Answers

Are you a Car and Truck Expert? Answer questions, earn points and help others

Answer questions