Blower is not working - 1999 Mercury Cougar

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Expert 318 Answers
  • Posted on Nov 15, 2009
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Jun 22, 2008
Answers
318
Questions
1
Helped
142428
Points
701

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Why would my blower, vent, defrost, ac and heater just quit blowing air?

There are several possible reasons why your blower, vent, defrost, AC, and heater might stop blowing air:

1. Blower Motor Failure: The blower motor is responsible for blowing the air through the vents. If the blower motor fails, you will not get any airflow from the vents.
2. Blower Motor Resistor Failure: The blower motor resistor controls the speed of the blower motor. If the resistor fails, the blower motor may stop working or only work at one speed.
3. Fuse or Relay Failure: A blown fuse or faulty relay in the blower motor circuit can prevent the blower motor from working.
4. Control Module Failure: The HVAC (heating, ventilation, and air conditioning) control module is responsible for controlling the blower motor and other components. If the control module fails, it can prevent the blower motor from working.
5. Vacuum Leak: If your vehicle uses a vacuum system to control the vents, a vacuum leak can prevent the system from working properly.
6. Broken Blend Door: The blend door controls the direction of the airflow. If the blend door breaks or gets stuck, the air may not flow through the correct vents.
7. Wiring or Connector Issues: Faulty wiring or connectors in the blower motor circuit can prevent the blower motor from working.
1helpful
1answer

I have dodge ram van 3500 2003 blower fan not working. I think the wires behind the stereo have something to do with it?

blower on heat or AC fails dead.
but must work on HIGH, does blower high work?
there is blower high relay that most work on high.
the relay closed for high , on high and mode not set to off.(0)
if HIGH works and lower speed do not work the blower resistor is blown out.
causes,
fuse f10 blown.
to test just the blower 1 of 2 pins, ground wire LG/WT light green /white blower must blow or blower is dead. (or key not ON)


the wiring is here.
https://eautorepair.net/Marketing/Default.asp
1helpful
2answers

2000 Chevrolet Impala blower motor work from 1-4 but not on 5th speed why?

The blower motor relay is energized when the Blower Motor Control is set to the High position. This removes the blower motor resistors from the circuit and battery voltage is then applied directly from the HVAC BLO fuse (RH IP Accessory Wiring Junction Block) to the blower motor though the relay switch contacts. The blower motor then runs at high speed.

HVAC Blower Controls Circuit Description
The blower motor is a variable speed motor. The motor operates at a higher rate when voltage is increased to the maximum level.
The blower motor resistors reduce the voltage supplied from the A/C FAN fuse (LH IP Accessory Wiring Junction Block) when the blower control is set at low and medium speeds (speeds 1-4). The blower motor relay is energized when the Blower Motor Control is set to the High position. This removes the blower motor resistors from the circuit and battery voltage is then applied directly from the HVAC BLO fuse (RH IP Accessory Wiring Junction Block) to the blower motor though the relay switch contacts. The blower motor then runs at high speed.
0helpful
1answer

2003 trailblazer blower not working

Are you saying the blower motor would run intermittently and then just stopped working? My first thought is faulty blower motor, I've seen faulty blower motors that would run intermittently. Any motor that uses brushes, you can tap on the motor to see if it will start working, that is a sign of bad motor brushes, replace the blower motor. There could be other issues?
Did you check the blower fuse, not only check the fuse, check the fuse circuit for voltage, use a test light. Check for applicable hvac trouble codes. With hvac on, check for voltage and ground at blower motor wiring connector, if both are good and no blower action, suspect the blower motor.
blower motor-ah4hlr42fk2bjlxp04hurvgv-3-0.jpg
0helpful
1answer

Heater is not working

HEATER BLOWER MOTOR


Its faulty blower motor resistor. The low and medium speed on blower motor is controlled by resistor and its actual speed is high. So because resistor is not working, blower motors actual speed which is high is working.


It can be faulty blower motor or faulty blower motor resistor. Get the blower motor inspected. If it's faulty it has to be replaced.


=======

For blower motor testing and replacing, check the link below: ----

Blower motor Testing/replacing for all vehicles?

http://repairhelpcenter.blogspot.in/2012/02/blower-motor-replacing-for-all-vehicles.html

------------

These will help.

Thanks.

0helpful
1answer

1996 SILHOUETTE BLOWER WILL NOT WORK

of the blower motor makes a howling or grinding noise the motor is going bad. blower control modules are common and will not give you all the blower speeds.
0helpful
1answer

When I turn on Blower the ac lt comes on but the

could be the blower motor or the blower motor resistor. if its the resistor the blower will usually work on high only with the settings not working. if it doesnt work on any setting it may be the blower motor itself
1helpful
1answer

2000 Wrangler blower won't work

HOT WIRE BLOWER MOTOR IF IT WORKS PROBLEM IN THE BLOWER RELAY AND RESISTOR.IF BLOWER DONT WORK REPLACE IT.
0helpful
1answer

Blower Motor not working

hello the problem your having with the blower motor sound like the blower itself the brushes could be worn out causing the extra load on the blower resistor you may need to have a blower motor installed hopefully you won't need the resistor hope this helps you



workitover
Not finding what you are looking for?

51 views

Ask a Question

Usually answered in minutes!

Top Mercury Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Arnie Burke
Arnie Burke

Level 3 Expert

7339 Answers

Are you a Mercury Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...