The heater control is stuck in the defrost and lower heat position. The knob turns but the air flow remains the same. I can not get panel airflow, full defrost, full heat,ect. Where do I start? The heat adjustment (temperature) knob works fine.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 1,111 Answers

You are sure the knob is not stripped right ....it all runs on vacuum look underneath and ensure they are all attached to the cluster on the knob as well check the vent itself and that the cable is not kinked preventing operation ..passengers side upper corner

Posted on Oct 12, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Need pitcure of vaccum lines on 1999 Ford Ranger v6 3.o air and heat blows only threw the defroster.


26392097-cvaukpwazi2vnl4fgradjhua-2-2.gif

Item Part Number Description 1 18A318 Vacuum Control Motor-, Panel/Defrost Door 2 18A478 Panel/Defrost Door (Full Vacuum Position) 3 - Defrost Air Flow 4 - Side Window Demister Air Flow 5 18B545 Temperature Blend Door (Full Heat Position) 6 19860 A/C Evaporator Core 7 19A813 Air Inlet Duct Door (Full Vacuum Position) 8 - Outside Air Inlet 9 18A318 Vacuum Control Motor-, Air Inlet Duct Door 10 - Recirculated Air Inlet 11 18527 Blower Motor 12 19A566 A/C Vacuum Reservoir Tank and Bracket 13 - Vacuum from the Engine Intake Manifold 14 19B888 A/C-Heater Function Selector Switch 15 - Vacuum to the 4x4 Hub Solenoids 16 18495 Water Diverter Valve (Full Vacuum Position) 17 18476 Heater Core 18 18A559 Floor/Panel Door (Full Vacuum Position) 19 - Floor Air Flow 20 18A318 Vacuum Control Motor-, Floor/Panel Door 21 - Panel Vent Air Flow

Dec 09, 2016 | Ford Ranger Cars & Trucks

1 Answer

Why wont my 2001 ford windstar blow out of vents ? only on defrost?


Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob , mounted on the heater function selector switch, which is part of the heater control .
  • The function selector knob has the following positions: OFF, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST.
  • The heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318) . Refer to the System Airflow Schematic and Vacuum Control Charts.
  • An internal single-pole electrical switch is also controlled by the selector. The switch controls the electrical supply to the heater blower motor switch (18578) .
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
  • You probably have a vacuum leak , Pull heater control panel an check for vacuum . A broke vacuum hose or The vacuum selector valve is bad ! Or check for a vacuum hose in the engine compartment being off somewhere !

Mar 08, 2015 | 2001 Ford Windstar

1 Answer

Pontiac Aztek airflow decreases when temperature dial turned to hot


Heater core may be restricted with excessive dust/dirt and debris, not allowing sufficient airflow to pass thru

Feb 17, 2014 | 2003 Pontiac Aztek

1 Answer

1997 Ford Taurus front defrost not working


. Air won't blow out of the floor or center vents just defrost ? Do you have manual or automatic climate control ?
Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob mounted on the A/C-heater function selector switch, which is part of the integrated control panel.
  • The function selector knob has the following positions: OFF, MAX A/C, A/C, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST. The A/C-heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318). Refer to the Vacuum Control Diagram , System Airflow Schematics and Vacuum Control Chart .
  • Two internal, single-pole electrical switches are also controlled by the A/C-heater function selector switch. The combination of these electrical switches controls the electrical supply to the A/C clutch and heater blower motor switch (18578).
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
  • Vacuum Control Motors The vacuum control motors (18A318):
    • are located on the A/C evaporator housing, A/C recirculation air duct and heater air plenum chamber (18471).
    • direct system airflow to the vehicle interior as determined by the remote climate control module or manual override.
    • The five-passenger seating configuration has an additional vacuum control motor mounted on the heater air plenum chamber to control airflow to the rear seat A/C register (19893).


vacuum control motor-i4bq0ig33y1522pr2d2rrkk3-2-0.gif

Jul 09, 2017 | Ford Cars & Trucks

2 Answers

I have a mercury mountaineer 2003 V6. It has a problem of making sound repeated when I want to have heat turned on. No sound when the dashboard A.C/Heat stays at AC level, which is the zero? level. The...


When the engine is cold,check the coolant level.

Make sure it's on max.

===

A coolant system should be flush every two years.

===

If you did a coolant flush recently then air pocket can be the cause of the un-even heating problem.

The DIY method is to drive you car onto a ramp or a steep hill.

Iet the engine cool off and top off the coolant tank.

Set MAX heat + MAX fan

Let the engine ran for 20 minutes wih the cap off and the trap air will escape from the coolant reserve tank,

Check coolant level and top off coolant when the engine cools down.



A shop will charge $75+ for this but using an air operated excavate tool!

========

A car with over 90K miles may experience linkage problem to the heater control valve.

The heater control valve (near the firewall) may be stick over time.

Open the hood and move the heater to max and min. Back and forth.

Clean and lube the linkage with WD-40 to free the heater control valve.

If it's a vacuum type heater control valve then cash for leaky vac. hoses.


=======
Move the fan switch back and forth to re-new the electrical conductors.

Pass a vacuum over the control panel to prevent dust build up behind the console.

Sep 13, 2009 | 2003 Mercury Mountaineer

1 Answer

I have the same problem with my windstar blower is fine but is coming cold air but no heat i dont know what to do can any one show me how to fix it thnx


First, feel the heater hoses going into the firewall under the hood. If they are hot, then you have hot engine coolant going into the heater core. If they are not hot, then you either have a bad thermostat or you are very low on engine coolant.

Next you need air flowing through the heater core so it can come out heated through your vents. If the iar is flowing somewhere else, your temp blend door is not moving because the bend door motor is bad or your temp knob on your heater controls is bad. The blend door motor is an electric motor.

------------------------------------------------
Air Flow Control
Air flow control is accomplished in the following manner:
  • Primary control is through the function selector knob , mounted on the heater function selector switch, which is part of the heater control .
  • The function selector knob has the following positions: OFF, PANEL, PANEL/FLOOR, FLOOR, FLOOR/DEFROST and DEFROST.
  • The heater function selector switch combines a vacuum selector valve with an internal electrical switch.
  • The vacuum selector valve directs source vacuum to various vacuum control motors (18A318) . Refer to the System Airflow Schematic and Vacuum Control Charts.
  • An internal single-pole electrical switch is also controlled by the selector. The switch controls the electrical supply to the heater blower motor switch (18578) .
  • The position of the function selector knob determines the manner in which the system will operate.
  • Each position of the function selector knob is detented for positive engagement.
Temperature Control
The temperature control operates in the following manner:
  • Temperature control of the heater system is determined by the position of the temperature control knob (between COOL-BLUE and WARM-RED) of the heater control .
  • This control knob is connected to a potentiometer mounted in the heater control . This potentiometer is electrically connected to the electric blend door actuator that operates the A/C air temperature control door.


e72a310.gif

  • Movement of the control knob from COOL (Blue) to WARM (Red) causes a corresponding movement on the air temperature control door and determines the temperature that the system will maintain.
System uses a reheat method to provide conditioned air to the passenger compartment.
  • All airflow from the blower motor (18527) passes through the A/C evaporator housing .
  • Temperature is then regulated by reheating a portion of the air and blending it with the remaining cool air to the desired temperature.
  • Temperature blending is varied by the air temperature control door, which regulates the amount of air that flows through and/or around the heater core (18476) , where it is then mixed and distributed.
--------------------------------------------------------------------------------------------------------------------------
inside you plenum box:

09f3f8a.gif

Mar 03, 2009 | 1998 Ford Windstar

1 Answer

Heater works ok but wont send air thru defrost vents


check the control knob it may appear to be working but is not turning the actual controller

Jan 01, 2009 | 1995 Pontiac Grand Am

2 Answers

Heater only blows thru dashboard vents, won't defrost


chech cable on back of cluster dial some time pops of causing issue.

Jan 01, 2009 | 1995 Pontiac Grand Am

1 Answer

Grand am heater works ok but wont defrost


check cable behind dials rod most likely off on that dial.

Jan 01, 2009 | 1994 Pontiac Grand Am

Not finding what you are looking for?

Open Questions:

See all 1995 Oldsmobile Cutlass Supreme Questions

1995 Oldsmobile Cutlass Supreme Logo

303 people viewed this question

Ask a Question

Usually answered in minutes!

Top Oldsmobile Experts

yadayada
yadayada

Level 3 Expert

76682 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22219 Answers

Jeff Turcotte
Jeff Turcotte

Level 3 Expert

8531 Answers

Are you an Oldsmobile Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...