Question about 2003 Audi A4 Cabriolet

1 Answer

All the windows and roof will not open. help!!!!!

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

  • Expert
  • 34 Answers

Check your fuses with a test light. Sometimes the fuses will look good and they will still be bad, ran into that yesterday on a 2002 Chrysler. Fuse looked perfect, but was not making complete connection.

Posted on Sep 25, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya Mechanic can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repair professionals here in the US.
click here to Talk to a Mechanic (only for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Sun roof won't close 2004 Ford Explorer


The roof opening panel is an electronically operated panel that can be opened or closed by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor. The vent and soft-stop functions are controlled by the roof opening panel motor. These positions are obtained when an internal motor cam opens the roof position switch, removing the ground from the switch. The roof opening panel has an express open feature activated when the switch is pressed momentarily. The roof opening panel is closed by continuous activation of the switch until the sunroof stops movement. This function is controlled by the roof opening panel motor.

Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Opening shield
  • Roof panel frame
  • Opening shield guide feet
  • Central junction box (CJB) fuses:
    • 2 (20A)
    • 29 (5A)
  • Battery junction box (BJB) fuse 1 (60A)
  • Accessory delay relay
  • Roof opening panel control switch
  • Circuitry
  • Roof opening panel motor

  • The roof opening panel does not open or close
  • Central junction box (CJB) fuse:
    • 2 (20A).
    • 29 (5A).
  • Battery junction box (BJB) fuse 1 (60A).
  • Circuitry.
  • Roof opening panel control switch.
  • Roof opening panel motor.
  • Go To Pinpoint Test E .

Do the power windows and power locks work ?

E6 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR - CIRCUITS 400 (LB/BK) AND 1173 (BN/OG)
  • Key in OFF position.
  • Disconnect: Roof Opening Panel Motor C920.
  • Key in ON position.
  • NOTE: Activate accessory delay relay for this check.
  • Measure the voltage between roof opening panel motor C920-4, circuit 400 (LB/BK), and ground; and between roof opening panel motor C920-7, circuit 1173 (BN/OG), and ground.
  • Are the voltages greater than 10 volts?
Yes
GO to E7 .

No
REPAIR circuit 400 (LB/BK) or circuit 1173 (BN/OG). TEST the system for normal operation. If you can't do electrical testing , there is a manual way to close it .
Roof Opening Panel Manual Operation
  1. Remove the overhead console. For additional information, refer to Overhead Console in this section.
  1. Insert a hex-head screwdriver in the center of the manual drive slot to depress the release pin. Rotate the screwdriver clockwise until the roof opening panel is closed.

Jan 13, 2017 | 2004 Ford Explorer

1 Answer

Sunroof will not close. Was working fine earlier today


The roof opening panel assembly uses an integrated motor and module to operate the roof opening panel. The roof opening panel motor and module are installed new as an assembly. The roof opening panel is an electronically operated glass panel that can be opened or closed by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor/module. The soft-stop function is controlled by the roof opening panel motor/module. The roof opening panel has 3 modes of operation, manual mode, express open and tilt. The express open feature is activated when the switch is pressed momentarily. The tilt feature is activated when the tilt switch is depressed. These functions are controlled by the roof opening panel motor/module.
Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Roof opening panel frame
  • Roof opening panel drain hoses
  • Roof opening panel lifter assemblies
  • Roof opening panel water trough
  • Roof opening panel rear trough guides
  • Roof opening panel air deflector assembly
  • Roof opening panel seal
  • Roof opening panel shield
  • Smart junction box (SJB) circuit breaker 47 (30A)
  • Circuitry
  • Accessory delay relay
  • Roof opening panel switch
  • The roof opening panel does not open or close - one direction only
  • Circuitry
  • Roof opening panel switch
  • Roof opening panel motor assembly
  • Go To Pinpoint Test E .
PINPOINT TEST E: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE Test Step Result / Action to Take E1 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES FOR OBSTRUCTIONS OR DAMAGE
  • Check the roof opening panel lifter assemblies for obstructions and damage.
  • Are the roof opening panel lifter assemblies OK?
Yes
GO to E2 .

No
REMOVE all obstructions and REPAIR any damage. If lifter assemblies cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel Frame in this section. TEST the system for normal operation. E2 CHECK THE ROOF OPENING PANEL WATER TROUGH AND REAR TROUGH GUIDES
  • Check the water roof opening panel water trough and rear trough guides for any loose obstructions.
  • Are the roof opening panel water trough and rear trough guides installed securely and free from obstructions?
Yes
GO to E3 .

No
REMOVE all obstructions from the roof opening panel water trough and install securely. SECURE the rear trough guides or INSTALL new roof opening panel rear trough guides if damaged. REFER to Roof Opening Panel Rear Trough Guide in this section. TEST the system for normal operation. E3 VERIFY THE ROOF OPENING PANEL ADJUSTMENT
  • Verify the roof opening panel is adjusted correctly.
  • Is the roof opening panel adjusted correctly?
Yes
GO to E4 .

No
ADJUST the roof opening panel. REFER to Roof Opening Panel Alignment - Horizontal Adjustment and Roof Opening Panel Alignment - Height Adjustment in this section. TEST the system for normal operation. E4 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR INITIALIZATION
    NOTE: The roof opening panel motor initialization procedure must be done when repairs are carried out on any part of the roof opening panel assembly, including whenever the roof opening panel motor/module has been removed from the roof opening panel assembly, a new roof opening panel motor/module has been installed or when a new roof opening panel assembly has been installed. Refer to Roof Opening Panel Motor Initialization in this section.
  • Carry out the Roof Opening Panel Motor Initialization procedure. Refer to Roof Opening Panel Motor Initialization in this section.
  • If the concern still present?
Yes
GO to E5 .

No
The system is operating correctly. The roof opening panel motor/module was uninitialized. E5 CHECK THE POWER WINDOWS
  • Key in ON position.
  • Verify the power windows operate.
  • Do the power windows operate?
Yes
GO to E6 .

No
REFER to Section 501-11 to diagnose the accessory delay relay circuit. E6 CHECK THE ROOF OPENING PANEL SWITCH
  • Carry out the roof opening panel switch component test. Refer to Wiring Diagrams Cell 149 for schematic and connector information.
  • Did the roof opening panel switch pass the component test?
Yes
GO to E7 .

No
INSTALL a new roof opening panel switch. TEST the system for normal operation. E7 CHECK CIRCUIT CBP47 (GN/BU) FOR VOLTAGE
  • Key in OFF position.
  • Disconnect: Roof Opening Panel Motor/Module C922.
  • Key in ON position.
  • Measure the voltage between roof opening panel motor/module C922-4, circuit CBP47 (GN/BU), harness side and ground.
    s7j~tr~en~file=a0083978.gif~gen~ref.gif
  • Is the voltage greater than 9 volts but less than 16 volts?
Yes
GO to E8 .

No
VERIFY the smart junction box (SJB) circuit breaker 47 (30A) is OK. If OK, REPAIR the circuit. TEST the system for normal operation. E8 CHECK CIRCUIT GD143 (BK/VT) FOR AN OPEN
  • Key in OFF position.
  • Measure the resistance between roof opening panel motor/module C922-3, circuit GD143 (BK/VT), harness side and ground.
    s7j~tr~en~file=a0084276.gif~gen~ref.gif
  • Is the resistance less than 5 ohms?
Yes
GO to E9 .

No
REPAIR the circuit. TEST the system for normal operation. E9 CHECK CIRCUITS CPR37 (YE/GY), CPR39 (VT/WH) AND CPR40 (YE/OG) FOR AN OPEN
  • Disconnect: Roof Opening Panel Switch C930.
  • Measure the resistance between the roof opening panel motor/module C922-1, circuit CPR40 (YE/OG), harness side and roof opening panel switch C930-8, circuit CPR40 (YE/OG), harness side. Measure the resistance between roof opening panel motor/module C922-2, circuit CPR39 (VT/WH), harness side and roof opening panel switch C930-11, circuit CPR39 (VT/WH), harness side. Measure the resistance between roof opening panel motor/module C922-5, circuit CPR37 (YE/GY), harness side and roof opening panel switch C930-14, circuit CPR37 (YE/GY), harness side.
    s7j~tr~en~file=n0054600.gif~gen~ref.gif
  • Are the resistances less than 5 ohms?
Yes
GO to E10 .

No
REPAIR the circuit. TEST the system for normal operation. E10 CHECK FOR CORRECT ROOF OPENING PANEL MOTOR/MODULE OPERATION
  • Disconnect the roof opening panel motor/module connectors.
  • Check for:
    • corrosion.
    • pushed-out pins.
  • Connect all roof opening panel motor/module connectors and make sure they seat correctly.
  • Operate the system and verify that the concern is still present.
  • Is the concern still present?
Yes
CHECK the jumper harness between the vehicle harness and the roof opening panel for open or shorted circuits. If the jumper harness is not OK, INSTALL a new jumper harness between the vehicle harness to the roof opening panel motor/module. Otherwise, INSTALL a new roof opening panel module/motor. REFER to Roof Opening Panel Motor in this section. TEST the system for normal operation.

No
The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.

May 08, 2016 | 2008 Ford Expedition El

1 Answer

Cannot find motor for sunroof in 1998 lincoln towncar limo


Before removing the motor ,check for B+ at the switch , in an out of the switch . Lincoln calls this a moon roof an there is a relay that powers it up . The location of relay an the motor is in the same place ,center of headliner behind the roof .
  • Sliding Roof Panel Does Not Open or Close
  • Damaged circuit breaker.
  • Circuitry open/shorted.
  • Damaged roof sliding panel switch.
  • Damaged sliding roof panel motor.
  • GO to Pinpoint Test E .
PINPOINT TEST E: SLIDING ROOF PANEL DOES NOT OPEN OR CLOSE E1 CHECK WINDOW OPERATION
  • Operate window.
Does window operate? Yes No GO to E2 . SERVICE safety relay circuits. REFER to Section 01-11 . E2 CHECK SUPPLY TO SLIDING ROOF PANEL MOTOR
  • Remove roof sliding panel switch as described.
  • Turn ignition switch to the RUN position.
  • Using a voltmeter connected to a known good ground, check Circuit 400 (LB/BK) at roof sliding panel switch connector C900 for voltage.
Is B+ present? Yes No GO to E3 . SERVICE open Circuit 400 (LB/BK). E3 CHECK SLIDING ROOF PANEL SWITCH GROUND
  • Using an ohmmeter connected to a known good ground, connect second lead to Circuit 57 (BK) at roof sliding panel switch connector C900 . Measure resistance.
Is resistance 5 ohms or less? Yes No INSTALL roof sliding panel switch. GO to E4 . SERVICE Circuit 57 (BK) for open circuit. RESTORE vehicle. RETEST system. E4 CHECK CIRCUIT 692 (R)
  • Using voltmeter connected to ground, back probe Circuit 692 (R) at roof sliding panel switch connector C901 .
  • Toggle roof sliding panel switch to the open position.
Is B+ present? Yes No GO to E5 . REPLACE damaged roof sliding panel switch. RESTORE vehicle. RETEST system. E5 CHECK ROOF SLIDING PANEL SWITCH
  • Using voltmeter connected to ground, back probe Circuit 691 (DB) at roof sliding panel switch connector C901 .
  • Toggle roof sliding panel switch to the closed position.
Is B+ present? Yes No GO to E6 . REPLACE damaged roof sliding panel switch. RESTORE vehicle. RETEST system. E6 CHECK SLIDING ROOF PANEL MOTOR
  • Gain access to sliding roof panel motor as described.
  • Using voltmeter, back probe sliding roof panel motor Circuit (DB) at connector C903 .
  • Toggle roof sliding panel switch to the closed position.
Is B+ present? Yes No GO to E7 . SERVICE Circuit (DB) for open. RESTORE vehicle. RETEST system. E7 CHECK CIRCUIT 692 (R/Y)
  • Using voltmeter, back probe sliding roof panel motor Circuit (R/Y) at connector C903 .
  • Toggle roof sliding panel switch to the open position.
Is B+ present? Yes No REPLACE damaged sliding roof panel motor. RESTORE vehicle. RETEST system. SERVICE Circuit (R/Y) for open. RESTORE vehicle. RETEST system.

Sep 20, 2015 | Lincoln Cars & Trucks

1 Answer

I have a 2004 mini cooper convertible. The roof opens to half way and will then flash red if i want it ti close all the way, All windows shut initally, but now when closing the roof the driver side rear...


I am not sure what you are trying to do. But if the problem is that the roof will only open to the first stage, sun roof, and no further, the problem is the package shelf in the trunk.

If the package lid gets pushed up and is not pushed back to it's normal position, the roof will fail to open completely. If you lift the bottom of the roof at the boot, there are levers on either side to release the bottom edge of the roof, you can make certain that the package shelf is seated correctly. Once the shelf is seated, the roof will open in all of it's glory.

Apr 20, 2011 | 2004 Mini Cooper

1 Answer

Sun Roof


i think you need a new motor for the sunroof

Jun 13, 2010 | 2001 Jaguar XJ8

1 Answer

Rear windows dont workfrom master switch after battery disconnect


You have to reset the windows and sunroof after you change the battery. For windows open the driver half way and close the window up and hold the up switch for few seconds. If that don't work open the rear window from rear switch and that should work.
For moon roof open the moon roof and keep the hold the open button pressed for 10 seconds. Then close the moon roof and hold the close button pressed for 10 seconds

Oct 05, 2009 | 2006 Lexus Gs 300

4 Answers

Sun roof will nt close cant find the rite fuse


check fuse F1.401, 30 amp in central junction box (in truck). Check your owner manual for fuse information.
Headliner must be removed to access motor.



Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Roof opening panel frame
  • Roof opening panel drain hoses
  • Roof opening panel lifter assemblies
  • Roof opening panel water trough
  • Roof opening panel air deflector assembly
  • Roof opening panel seal
  • Roof opening panel shield
  • Battery junction box (BJB) fuse
  • Circuitry
  • Accessory delay relay
  • Roof opening panel switch


  • The roof opening panel does not open or close
  • Roof opening panel adjustment.
  • Battery junction box (BJB) fuse.
  • Circuitry.
  • Roof opening panel switch.
  • Roof opening panel motor assembly.
  • Roof opening panel lifter assemblies.


  • The roof opening panel does not open or close — one direction only
  • Circuitry.
  • Roof opening panel switch.
  • Roof opening panel motor assembly.



Apr 10, 2009 | 2003 Lincoln Navigator

1 Answer

I have no power to my 1999 explorer sunroof



Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Opening shield
  • Roof panel frame
  • Opening shield guide feet
  • Fuse junction panel Fuse 26 (10A)
  • Battery junction box Fuse 4 (30A) maxifuse
  • Relays
  • Roof opening panel switch
  • Wiring harness
  • roof opening panel motor

------------------------------------------------------------------------------------------
  • The roof opening panel does not open or close
  • Fuse junction panel Fuse 26 (10A).
  • Battery junction box Fuse 4 (30A).
  • Circuitry.
  • Switch.
  • Roof opening panel motor.

do the power door locks worK?


Mar 21, 2009 | Ford Explorer Sport Cars & Trucks

Not finding what you are looking for?
2003 Audi A4 Cabriolet Logo

Related Topics:

80 people viewed this question

Ask a Question

Usually answered in minutes!

Top Audi Experts

Colin Stickland
Colin Stickland

Level 3 Expert

22265 Answers

yadayada
yadayada

Level 3 Expert

77186 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

14384 Answers

Are you an Audi Expert? Answer questions, earn points and help others