I have a 2012 Ford Econoline put in complete new system everything works fine until I am driving then I lose air flow in the cabin can feel cold air but not blowing out the vents

5 Related Answers

Anonymous

  • 1 Answer
  • Posted on Jul 22, 2008

SOURCE: There is no air flow

You need part GM Part number 89018675 or ACDelco 15-73596. The Mode Selector Actuator. What happens is the part is a CHEAP part POORLY designed and when it goes to turn the flaps inside the HVAC unit its the plastic gear slips instead of turning the flap!!!

Just to forward you you might want a deal to install this art for you unless your good at fixing your own vehicle, because you need SMALL sockets and a lot of patience to get this part in!!!

The part is ALMOST directly above the steering shaft for your steering wheel, so theres a lot you got to remove before you will even see them!!!

I only recommend you to have a dealer put this part in for you, unless you have your own service manual!!

Because there is 5 of these darn things and if you pick the wrong one you will have to do it all over again!!!

3 on the Drivers side and 2 on the Passengers side!!

But replacing this part SHOULD solve all your problems!! AS it did for me and i was having the same issues as you have described!!


Ad

Denis Aube

  • 142 Answers
  • Posted on Aug 28, 2008

SOURCE: a/c problem

You either have a bad control, or motor running the air direction door in the front HVAC unit, or a door that is stuck.

The front and rear units are totally separate.

The door directs where the air, cold or hot, should come out, whether it is panel vents, floor, defrost, or any combination of those.

This door and motor are located inside the heater box which usually requires a lot of the vehicle dash assembly to be taken apart to get to these parts.

Stan R

  • 37 Answers
  • Posted on Mar 13, 2009

SOURCE: PROBLEM WHEN SELECTING THE DIRECTION FOR THE AIR

Sounds like you have a supply vacuum problem. When you lose supply vacuum to the control head it defaults to defrost.

Anonymous

  • 1 Answer
  • Posted on Apr 07, 2009

SOURCE: 2003 Ford Explorer. A/c blows cold, but not from front of vents

I have the 03 Expy with continuous rear air unit "clicking" or more accurately flapping of the air damper while the plastic gears in the 2L2H-19E616-AA grind away into toothlessness. Ford designed this unit to find the end of travel by jamming the motor to a stop and monitoring the current to determine when to stop applying voltage. That would probably be fine if the gears were designed to handle the jammed torque or the motor did not slip out of groove and continue turning and cracking the plastic gears.

There are two white colored boxes, one is for the temp plenum door, the other the upper/lower air flow. To be sure, do what I did, turn on the ignition, rear ac/heat and listen for the obnoxious click/thump as you move the temp control from full heat to full cool, you will know which part. Disconnect the electrical connector, four bolts and it is out!

Go to your dealer, part should be about $60 or less, look on line, lots of dealers sell for this or less on internet.

mkv0525

Mike Vincent

  • 358 Answers
  • Posted on Jun 16, 2009

SOURCE: 2004 toyota sienna a/c not working one side cold other side warm

there are two a/c lines that run down the fire wall under the van to the rear.right around the bottom of the fire wall the is a connection point on both lines. you will find a leak there .replace the orings and recharge system. also you will need two specail toyota tools to release the couplings.i have done this repair on several sienna's. let me know if this helps.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer
0helpful
1answer

My 2005 monte carlo heater blows cold air from drivers vents and warm air form passenger vents but it fluctuates as I drive. Sometimes though it works fine and blows normal hot air like it should.

Those engines are well known to lose cabin heat do to low coolant , and air trapped in upper cooling system will stop flow to heater core . I would check that first . If not that , the vacuumed controed vent flaps under the dash are not working properly maybe becauss of a vacuumed leak or electrical problem .
0helpful
1answer

No heat from vents

As per your problem mentioned. There are few solved help links to troubleshoot these problems. Go through the list and Click the link below:----

2000 Toyota Avalon: No heat on Passenger Side?

http://whatisbyme.blogspot.in/2012/05/2000-toyota-avalon-no-heat-on-passenger.html

------------

No heat on Oldsmobile Silhouette?


http://technoanswers.blogspot.in/2012/02/no-heat-on-oldsmobile-silhouette.html

------------

Heater blows cold?

http://schematicsdiagram.blogspot.in/2012/02/heater-blows-cold.html

-----------

Heat blows cold on drivers side and hot on passenger side?

http://schematicsdiagram.blogspot.com/2011/12/heat-blows-cold-on-drivers-side-and-hot.html

----------

Hot air on the driver's side vents only?

http://repairhelpcenter.blogspot.com/2012/01/hot-air-on-drivers-side-vents-only.html

--------------

Temperature gauge does not move and no heat when heater is ON?

http://technoanswers.blogspot.com/2012/01/temperature-gauge-does-not-move-and-no.html

-----------

1992 Toyota Camry: A/C Control light Flashing and A/C not Blowing Cold?

http://technoanswers.blogspot.in/2012/04/1992-toyota-camry-ac-control-light.html

--------------


No heat, blower blows only cold?

http://technoanswers.blogspot.in/2012/02/no-heatblower-blows-only-cold.html
----------

Ford F150 Ac only blows through defrost vents?

http://technoanswers.blogspot.com/2012/01/forf-f150-ac-only-blows-through-defrost.html

----------

Dodge A/C come out of defrost vents only?

http://technoanswers.blogspot.com/2012/01/dodge-ac-come-out-of-defrost-vents-only.html

---------

Ac vacuum line on dodge cummins?

http://technoanswers.blogspot.com/2012/01/ac-vacuum-line-on-dodge-cummins.html

---------

Ford ranger AC blows cold through defrost vents instead on cabin vents?

http://technoanswers.blogspot.com/2012/01/ford-ranger-ac-blows-cold-through.html

----------

2005 Chrysler PT Cruiser: A/C Blows Warm?

http://whoisbyme.blogspot.in/2012/06/2005-chrysler-p8t-cruiser-ac-blows-warm.html


-------------

2009 Mercury Grand Marquis: A/C blows Cold From Defrost Vent Only?

http://whoisbyme.blogspot.in/2012/06/2009-mercury-grand-marquis-ac-blows.html

-----------

AC not blowing through Vents on 2007 Chevy Trailblazer?

http://schematicsdiagram.blogspot.in/2012/04/ac-not-blowing-through-vents-on-2007.html

----------

Passenger side temperature is warm air out of dash vents?

http://schematicsdiagram.blogspot.in/2012/04/passenger-side-temperature-is-warm-air.html

----------


These will help.

Thanks.

1helpful
1answer

My 2004 mitsubishi galant isnt blowing cold or hot air.

If it has a cabin air filter the filter could be blocked.
It could also have a stuck or faulty blend door that directs air flow thru the HVAC box.
2helpful
2answers

Ac is blowing out of defrosterandnot panels in the dash. Air is cool cold air will blow out of rear seat panel/vent 1998 ford explored

The most common cause is a bad blend door actuator which controls air flow throughout the cabin. When air flow only flows from 1 section (either floor, vent, or defrost) it's an indication that the blend door actuator is either stuck or broken.
1helpful
1answer

2005 focus blows cold air then will stop and nornal air comes turn off car leave for awhile and it does same thing when restarted starts cold then stops cheers steve

your cabin air filter is probably clogged up, that can cause the ac to actually freeze up and wont feel cold until the car stops and thaws out. replace your cabin filter and see if it doesnt help. ehow.com has a good step by step for the process.
0helpful
1answer

I have a 2004 Buick Century. Over the weekend I seemed to have lost the oomph on my air flow, I checked the filter for the cabin air. Took it out and ran the system but still no help. The A/C works fine...

Feel,and make sure there is no air coming from the floor,or the defrost,if not,then the directional door is working,but if not,there will be a actuator motor that controls this not moving all the way,the other choice would be that the evaporator is stopped up with debris,from outside air flow.Of course the dash and blower box would have to be removed to repair the problem.
2helpful
1answer

Heat in a Econoline 150 just stopped. Blows out cold air. Dont have fuse diagram where do I find one

I'm not sure your problem is a blown fuse. If the blower motor is running and pushing out air, then it's working normally. First check would be the thermostat, let the engine warm up and feel the radiator hoses. If 1 hose gets hot and the other is cold, most likely you have a bad thermostat. If thats ok, make sure you dont have any vacuum leaks, as most of the blend air doors that allow heat into the van are vacuum operated. It doesnt take much of a vacuum leak to lose your heat. Finally, make sure the control cables behind the head unit are in place and not kinked or broken.
Not finding what you are looking for?

35 views

Ask a Question

Usually answered in minutes!

Top Ford Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

xxxxxx xxx

Level 3 Expert

5117 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...