Blower will not work replace blower and relay

Posted by on

  • leone C Jan 01, 2017

    Even with a bad resistor it will work on full bast number 4, is independent from the resistor witch works with 1,2,3 heating settings ,if not your fan is no good

×

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Cars & Trucks Master
  • 12,168 Answers

Testing the electrical circuit is the proper way to diagnose a non working blower motor . There are videos on youtube showing how to do trouble shooting . Blower Motor Problems Auto Repair Help

Posted on Jan 01, 2017

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 261 Answers

SOURCE: Heater Fan/Blower does not work.

what you need is a blower motor resistot

Posted on Dec 04, 2008

  • 1 Answer

SOURCE: 1998 ford contour blower motor not working

I have a 1998 Ford Contour. Believe it or not the ABS and the Blower Motor share the same fuse. It's a yellow 60 amp and you have to take off the battery to get at it. Of course this happened twice in the 6 years I had the car, both times in the dead of winter. Tires Plus in Pennsauken, NJ replaced it. Other than that, no complaints with my Contour.

Posted on Feb 11, 2009

SOURCE: blower motor does not work

I had the same problem, replace, replace, replace. Check, check and recheck. What I found was the blower motor resistor, located in the blower squirrel cage area, two prongs and a curly wire, was bad. Took the new one back, (it ohmed out okay, continuity ok, all ok!) replaced it with another, and Bingo, problem solved. Frustrating to say the least. After two relays and a blower switch, and test, test and retest. It was a faulty resistor. Made in Mexico. And no guarentee, even though new, it works. Trial and error. Even the dealer parts are Honcho en Mexico. Thanks NAFTA. You gonna make us all welfare babies.

Posted on Sep 28, 2009

  • 1 Answer

SOURCE: 2004 chrysler pacifica, front blower not working,

replace restor open glove box uplug 4 wire plug and two wire plug put 12 volts two wire plug to mke sure fan works if it does replace restor

Posted on Dec 27, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

I have replaced the blower relay, the resistor looks fine, but blower won't work on my 1986 Silverado


Change the resistor. For the 15-20 bucks it's a great diagnostic and a very common problem with GM vehicles.
Then you can start backtracing the harness as ray012965 suggested.

Dec 16, 2014 | Cars & Trucks

1 Answer

2004 blower moter keeps running


i would replace the blower motor relay .sounds like its stuck in the closed postion, normanlly it in the open . if you have a owner manual go to the index and look at relays ,locate relay pull it out and if it stops the blower with the key off its probally your problem..

Aug 05, 2012 | 2004 Chrysler Pacifica

1 Answer

Blower not working. have replaced the motor resister. what next? Does anyone know how to trouble shoot this system?


REPLACE BLOWER MOTOR RELAY.HOOK TEST LIGHT SEE POWER GOING TO BLOWER MOTOR IF YES BLOWER MOTOR FAULTY.IF NO POWER GOING TO BLOWER MOTOR, FAULTY RELAY, FAULTY CONTROL SWITCH OR POOR GROUND AT WIRE TO BLOWER MOTOR.

Jul 05, 2011 | Chrysler Voyager Cars & Trucks

1 Answer

Front blower motor will not blow out heat or nothing, if i replaced the relay in the fuse box in side suv could that work. relay for blower motor, also not sure which one is the relay in the fuse box.


This may be a faulty Blower motor resistor, usually mounted inside the blower motor air box, or defective blower motor. There is no single Relay for the blower motor.

Dec 11, 2010 | 2004 Mitsubishi Endeavor

1 Answer

Front blower dont work but back blower works


First Check the Front Blower Relay located in the IPM Fuses and Relay box in the Engine Compartment. There should be individual Front and Rear Blower Relays. The Identification and Location should be on the rear of the IPM Cover. If not check your Owner's Manual.
Switch these two Relays and recheck operation of the Front and Rear Blowers again. If the Front now works and the Rear does not, then the Relay was bad and needs to be replaced.
However the most common problems I have found is that the Front Blower only works on High. Is that the Case? Check it to be sure. If it only works on High then it is 100% the Resistor that is bad and needs to be replaced. The Front Blower Motor Resistor fail in these more often that the Blower Motor itself.
Remove the Dash Glove Box out of the Dash to gain access to the Resistor.
Let me know if this helped, or if you have additional information or questions. Feel free to contact me at FixYa.Com!

Feb 16, 2010 | 2004 Dodge Grand Caravan

1 Answer

Blower motor does not work


I had the same problem, replace, replace, replace. Check, check and recheck. What I found was the blower motor resistor, located in the blower squirrel cage area, two prongs and a curly wire, was bad. Took the new one back, (it ohmed out okay, continuity ok, all ok!) replaced it with another, and Bingo, problem solved. Frustrating to say the least. After two relays and a blower switch, and test, test and retest. It was a faulty resistor. Made in Mexico. And no guarentee, even though new, it works. Trial and error. Even the dealer parts are Honcho en Mexico. Thanks NAFTA. You gonna make us all welfare babies.

Sep 28, 2009 | 1997 Jeep Grand Cherokee

1 Answer

G6 - blower won't work on 1st speed.....


If the blower doesnt work on 1st speed it could be three things the blower itself, the blower relay, or the speed control on your consoul. the most common problem on chevy vehicles is the speed control.

Aug 10, 2009 | 2005 Pontiac G6

1 Answer

Blower working on top 2 settings but no air comeing from vents


Hi

Thanks for using FixYa. The possible causes due to which the blower is not working normally are fuse, blower resistor or a bad blower motor. Test the voltage at the blower with a test light. Please check the motor relay switch fuse under the dashboard. Use a multi meter to measure ohms for continuity. If these are fine, bypass the blower motor relay switch to make sure blower motor is running fine. Motor relay switch is right next to radiator fan relay switch under the hood. Pull out the blower motor relay switch to see 4 female pin holes. Test the relay switch using a 12 volts power source and a multi meter to measure continuity. If fan works after jumping the pin holes, then blower motor is fine but relay switch may be faulty. You may also need to replace the blower motor resistor. If still the problem persists, then you need to replace the blower motor.

Please do rate the solution and revert for further assistance.


Thanks
Rylee

Aug 09, 2009 | 1997 Honda Civic

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

15 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cars & Trucks Experts

yadayada
yadayada

Level 3 Expert

76649 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22219 Answers

Randy Ohler

Level 3 Expert

14585 Answers

Are you a Car and Truck Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...