Question about Cars & Trucks

Open Question

How do you get in to the blower - Cars & Trucks

Posted by on

  • Brad Brown Dec 07, 2016

    Hi bill shire, I want to help you with your question, but I need more information from you. Can you please add details in the comment box? On what

×

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Blower fan not working at all 2004 Buick rendezvous


Which system ?
HVAC Systems - Manual HVAC Systems - Automatic
If automatic it's probably the blower motor control processor .
Blower Motor Control Processor The blower motor control processor is an interface between the HVAC control module and the blower motor. The blower motor speed control, Blower motor speed signal, battery positive voltage and ground circuits enable the control processor to operate. The HVAC control module sends the commanded blower motor speed to the control processor through a 0 to 12-volt linear ramped blower motor speed control circuit. As the blower motor speed control voltage increases, the blower motor speed increases. The control processor sends the actual blower speed to the control module through a 0 to 12-volt blower motor speed signal circuit. The processor supplies 12volts to the blower motor through the blower motor voltage supply circuit. The control processor uses the blower motor ground as a low side control to adjust the blower motor speed.

Nov 19, 2016 | Buick Cars & Trucks

1 Answer

How to change ac blower on a 2001 chevy silverado with the 5.3 liter v8


With Delphi Blower Motor
  1. If equipped, remove the sound insulator panel.
  2. Remove the blower motor insulating cover screws.
  3. Disconnect the electrical connector from the blower motor.
  4. Remove the blower motor insulating cover.
  5. Pull the retaining tab down while turning the blower motor counterclockwise in order to disengage the blower motor from the heater/ventilation module.
  6. Remove the blower motor.

With Visteon Blower Motor
  1. Remove the sound insulator panel.
  2. Disconnect the electrical connector from the blower motor.
  3. Remove the screws from the blower motor.
  4. Remove the blower motor from the HVAC module.
  5. Remove the retainer from the blower motor wheel. Discard the retainer.
  6. Remove the blower motor wheel from the blower motor.

Jul 27, 2014 | 2001 Chevrolet Silverado

1 Answer

Blower stays on after key is removed, now a/c works in front once I hit the highway.


Which of these systems does your vehicle have ?
HVAC Systems - Automatic
Blower Motor Control Processor
The blower motor control processor controls the speed of the blower motor by increasing or decreasing the voltage drop on the ground side of the blower motor. The HVAC control module provides a voltage signal to the blower motor control processor over the blower motor speed control circuit. As the requested blower speed increases, the HVAC control module increases the amount of time that the speed signal is modulated to ground. As the requested blower speed decreases, the HVAC control module decreases the amount of time that the signal is modulated to ground.

HVAC Systems - Manual
Air Speed - Front Control
The blower motor forces outside air into the vehicle's interior. The vehicle operator determines the blower motor's speed when the driver places the blower switch in one of 5 blower speeds. The blower motor will always operate in any switch position other than OFF, as long as the ignition switch is in the RUN position. The blower motor and mode switches are located within the HVAC control module. The blower motor OFF input is connected in series with the HVAC control module by the off blower motor control circuit.
Depending upon the selected speed, power is provided to the blower motor from either the ignition 3 voltage or battery positive voltage circuits from the fuse block. The battery positive voltage circuit only provides power when the High blower switch position is selected. Power and ground are provided to the HVAC control module by the ignition 3 voltage and the ground circuits.
Low Blower Speed
When the Low 1 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the low blower motor control circuit. Voltage is divided between 4 series resistors, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
Medium Blower Speeds
When the Medium 1 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the medium 1 blower motor control circuit. Voltage is divided between 3 series resistors, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
When the Medium 2 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the medium 2 blower motor control circuit. Voltage is divided between 2 series resistors, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
When the Medium 3 blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the medium 3 blower motor control circuit. Voltage is divided between a series resistor, a blower relay, and the blower motor to achieve the desired blower speed. The blower motor is grounded through the ground circuit.
High Blower Speed
When the High blower speed is selected, the HVAC control module applies voltage to the blower motor resistor assembly through the high blower motor control circuit. The voltage energizes the blower relay, causing the blower motor to be connected directly to the battery positive voltage circuit. The blower motor and blower motor relay are grounded through the ground circuit.

HVAC Control Module
The HVAC control module is a class 2 device that interfaces between the operator and the HVAC system to maintain air temperature and distribution settings. The battery positive voltage circuit provides power that the control module uses for keep alive memory (KAM). If the battery positive voltage circuit loses power, all HVAC DTCs and settings will be erased from KAM. The body control module (BCM), which is the vehicle mode master, provides a device on signal. The control module supports the following features:

Feb 09, 2018 | 2005 Chevrolet Tahoe

1 Answer

The heater blower stopped working and the fuse is not blown?


Blower Motor Removal & Installation W/O Air Conditioning Blower Motor (W/O Air Conditioning) gm-10-00-634.gif

To Remove:
  1. Remove the PCM.
  2. Remove the coolant reservoir.
  3. Remove the rear coolant recovery reservoir mounting stud.
  4. Disconnect the cooling tube from the blower motor.
  5. Disconnect the electrical connector from the blower motor.
  6. Remove the blower motor mounting bolts.
  7. Remove the blower motor insulating cover.
  8. Remove the blower motor.
To Install:
  1. Install the blower motor.
  2. Install the blower motor mounting bolts.
  3. Connect the electrical connector to the blower motor.
  4. Connect the cooling tube to the blower motor.
  5. Install the rear coolant recovery reservoir mounting stud.
  6. Install the coolant reservoir.
  7. Install the PCM.
W/ Air Conditioning Blower Motor (W/ Air Conditioning) gm-10-00-633.gif

To Remove:
  1. Remove the PCM.
  2. Remove the coolant reservoir.
  3. Remove the rear coolant recovery reservoir mounting stud.
  4. Disconnect the electrical connector from the blower motor.
  5. Move the PCM connectors out of the way.
  6. Remove the blower motor access cover screws. CAUTION
    Do not cut any deeper than necessary in order to remove the access cover.
  7. Cut through the access cover on the cut line using a sharp utility knife.
  8. Disconnect the cooling tube from the blower motor.
  9. Remove the blower motor mounting bolts.
  10. Remove the blower motor.
To Install:
  1. Install the blower motor.
  2. Install the blower motor mounting bolts.
  3. Connect the cooling tube to the blower motor.
  4. Install the blower motor access cover.
  5. Install the blower motor access cover retaining screws.
  6. Using black weather-strip adhesive, seal the cut line.
  7. Connect the blower motor electrical connector.
  8. Reposition the PCM connectors.
  9. Install the rear coolant recovery reservoir mounting stud.
  10. Install the coolant reservoir.
  11. Install the PCM.
prev.gif next.gif

Feb 08, 2011 | 1996 Chevrolet Blazer

1 Answer

How to change blowermotor on 2001 gmc jimmy


Blower Motor Removal & Installation W/O Air Conditioning Blower Motor (W/O Air Conditioning) gm-10-00-634.gif

To Remove:
  1. Remove the PCM.
  2. Remove the coolant reservoir.
  3. Remove the rear coolant recovery reservoir mounting stud.
  4. Disconnect the cooling tube from the blower motor.
  5. Disconnect the electrical connector from the blower motor.
  6. Remove the blower motor mounting bolts.
  7. Remove the blower motor insulating cover.
  8. Remove the blower motor.
To Install:
  1. Install the blower motor.
  2. Install the blower motor mounting bolts.
  3. Connect the electrical connector to the blower motor.
  4. Connect the cooling tube to the blower motor.
  5. Install the rear coolant recovery reservoir mounting stud.
  6. Install the coolant reservoir.
  7. Install the PCM.
W/ Air Conditioning Blower Motor (W/ Air Conditioning) gm-10-00-633.gif

To Remove:
  1. Remove the PCM.
  2. Remove the coolant reservoir.
  3. Remove the rear coolant recovery reservoir mounting stud.
  4. Disconnect the electrical connector from the blower motor.
  5. Move the PCM connectors out of the way.
  6. Remove the blower motor access cover screws. CAUTION
    Do not cut any deeper than necessary in order to remove the access cover.
  7. Cut through the access cover on the cut line using a sharp utility knife.
  8. Disconnect the cooling tube from the blower motor.
  9. Remove the blower motor mounting bolts.
  10. Remove the blower motor.
To Install:
  1. Install the blower motor.
  2. Install the blower motor mounting bolts.
  3. Connect the cooling tube to the blower motor.
  4. Install the blower motor access cover.
  5. Install the blower motor access cover retaining screws.
  6. Using black weather-strip adhesive, seal the cut line.
  7. Connect the blower motor electrical connector.
  8. Reposition the PCM connectors.
  9. Install the rear coolant recovery reservoir mounting stud.
  10. Install the coolant reservoir.
  11. Install the PCM.
prev.gif next.gif

Dec 08, 2010 | 2001 GMC Jimmy

1 Answer

How to install a front blower motor in a 96 ford explorer


Blower Motor - REMOVAL & INSTALLATION
(see Figures 1 and 2)

8e5714d.jpg

Fig. 1: Exploded view of the blower motor mounting

ff3bdf8.jpg

Fig. 2: Exploded view of the blower motor and wheel (fan) assembly

Without Air Conditioning

  1. Disconnect the negative battery cable.
  2. Remove the air cleaner or air inlet duct, as necessary.
  3. If necessary, Remove the speed control module and the washer fluid reservoir.

2587a00.jpg

Fig. 3: To remove the blower motor, first disconnect the electrical wire harness plug...

f234e79.jpg

Fig. 4: ...then remove the blower motor cooling tube from the motor
  1. Disconnect the wire harness connector from the blower motor by pushing down on the connector tabs and pulling the connector off of the motor.
  2. Disconnect the blower motor cooling tube at the blower motor.
3bbd0e1.jpg

Fig. 5: Remove the blower motor attaching screws and the washer fluid reservoir...

8da3ac1.jpg

Fig. 6: ...then slide the blower motor from the housing. Take care to not damage the blower wheel (arrow)
  1. Remove the 2 screws attaching the blower motor and wheel to the heater blower assembly.
  2. Holding the cooling tube aside, pull the blower motor and wheel from the heater blower assembly and remove it from the vehicle.
  3. Remove the blower wheel push-nut and/or clamp from the motor shaft and pull the blower wheel from the motor shaft.
To install:
  1. Install the blower wheel on the blower motor shaft.
  2. Install the hub clamp and/or push-nut.
  3. Holding the cooling tube aside, position the blower motor and wheel on the heater blower assembly and install the 2 attaching screws.
  4. Connect the blower motor cooling tube and the wire harness connector.
  5. Install the vacuum reservoir on the hoses with the 1 screws.
  6. If removed, install the speed control module and the washer fluid reservoir.
  7. Install the air cleaner or air inlet duct, as necessary.
  8. Connect the negative battery cable and check the system for proper operation.

With Air Conditioning
  1. Disconnect the negative battery cable.
  2. In the engine compartment, disconnect the wire harness from the motor by pushing down on the tab while pulling the connection off at the motor.
  3. Remove the air cleaner or air inlet duct, as necessary.
  4. If necessary, remove the solenoid box cover retaining bolts and the solenoid box cover.
  5. Disconnect the blower motor cooling tube from the blower motor.
  6. Remove the blower motor mounting plate attaching screws and remove the motor and wheel assembly from the evaporator assembly blower motor housing.
  7. Remove the blower motor hub clamp from the motor shaft and pull the blower wheel from the shaft.
To install:
  1. Install the blower motor wheel on the blower motor shaft and install a new hub clamp.
  2. Install a new motor mounting seal on the blower housing before installing the blower motor.
  3. Position the blower motor and wheel assembly in the blower housing and install the attaching screws.
  4. Connect the blower motor cooling tube.
  5. Connect the electrical wire harness hard shell connector to the blower motor by pushing into place.
  6. If removed, position the solenoid box cover into place and install the 2 retaining screws.
  7. Install the air cleaner or air inlet duct, as necessary.
  8. Connect the negative battery cable and check the blower motor in all speeds for proper operation.

Hope this help (remember comment and rated this).

Apr 23, 2010 | 1996 Ford Explorer

1 Answer

How to replace the blower motor fan assembly in a 2000 GMC Yukon XL K1500 4X4


Blower Motor Removal & Installation Delphi
Blower Motor Replacement (Delphi)

1fb4643.gif
To Remove:
  1. Remove the instrument panel sound insulator panel (if equipped).
  2. Disconnect the electrical connector from the blower motor.
  3. Remove the blower motor insulating cover screws.
  4. Remove the blower motor insulating cover.
  5. Pull the retaining tab down and rotate blower motor counterclockwise to remove.
To Install:

  1. Position the blower motor and turn assembly clockwise until tab locks in place.
  2. Install the blower motor insulating cover.
  3. Connect the electrical connector to the blower motor.
  4. Install the instrument panel sound insulator panel (if equipped).

Visteon

Blower Motor Replacement (Visteon)

878e8d8.gif
To Remove:
  1. Remove the instrument panel sound insulator panel (if equipped).
  2. Disconnect the electrical connector from the blower motor.
  3. Remove the blower motor screws.
  4. Remove the blower motor from the HVAC module.
To Install:
  1. Position the blower motor and install mounting screws.
  2. Connect the electrical connector to the blower motor.
  3. Install the instrument panel sound insulator panel (if equipped).

Oct 02, 2009 | 2000 GMC Yukon XL

1 Answer

Blower motor


PART 1
If all blower speeds are not working I would check the blower, but if only one speed is not working I would check the resistor block for the blower it controls the speeds. they use 2 different blowers in this truck I have to sent a second message with the rest it will not hold it all inthis message.

2001–05 Models With Delphi Blower Motor
  1. If equipped, remove the sound insulator panel.
  2. Remove the blower motor insulating cover screws.
  3. Disconnect the electrical connector from the blower motor.
  4. Remove the blower motor insulating cover.
  5. Pull the retaining tab down while turning the blower motor counterclockwise in order to disengage the blower motor from the heater/ventilation module.
  6. Remove the blower motor.
c93043c.jpgPull the retaining tab down while turning the blower motor counterclockwise in order to disengage the blower motor

To install:
  1. Install the blower motor.
  2. Install the blower motor to the heater/ventilation module. Turn the blower assembly clockwise until the retaining tab locks into place.
  3. Install the blower motor insulating cover.
  4. Connect the electrical connector to the blower motor.
  5. Install the blower motor insulating cover screws.
    1. Tighten the screws to 14 inch lbs. (1.6 Nm).
  6. If equipped, install the sound insulator panel

Nov 27, 2008 | 2004 Chevrolet Silverado

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

14 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cars & Trucks Experts

yadayada
yadayada

Level 3 Expert

79024 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22326 Answers

john h

Level 3 Expert

13652 Answers

Are you a Car and Truck Expert? Answer questions, earn points and help others

Answer questions