SOURCE: ford fusion 1.4 tdci will not start unless the hand pump is used
HAVE YOU CHECKED THE FUEL LINES WHERE THE FUEL PRIMING PUMP IS CONNECTED FOR ANY CHAFFING THEY ARE COMMON FOR CHAFFING BESIDE THE FUEL FILTER WHICH WOULD EXPLAIN WHY FUEL IS RETURNING TO FUEL TANK.
SOURCE: can i use biodiesel in a 1.4 tdci
I recommend using no more than B20 (20% biodiesel) unless you are willing to replace some fuel lines, because pure biodiesel can dissolve them over time in vehicles not designed for biodiesel.
The fuel filter issue is also correct on vehicles that have been running on dino diesel. Consider getting both filters changed shortly after you switch (maybe 1000 miles or as soon as you notice any driveability problems).
SOURCE: have a code p0010 on
P0010 - Intake Camshaft Position Actuator Circuit Open Bank 1
Possible Causes:
- Variable Camshaft Timing (VCT) position circuit is open or shorted
- Variable Camshaft Timing (VCT) position circuit poor electrical connection
- Faulty Variable Camshaft Timing (VCT) position solenoid
SOURCE: ford fusion gas cap light keeps coming on
Any number of EVAP System issues
What was the code?
A small leak doesn't just have to be a gas cap
Have the system smoke tested
Testimonial: "Any idea what that costs?"
145 views
Usually answered in minutes!
×