What would cause the fuse to keep blowing on the fuel pump for a 2004 Isuzu rodeo?

2 Answers

_-__-___-_

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Isuzu Master 20,706 Answers
  • Posted on Jan 12, 2016
_-__-___-_
Isuzu Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Apr 06, 2013
Answers
20706
Questions
2
Helped
6794469
Points
57965

I missed this. an NO engine stated, 3.2 or 3.5 DI?????????
car have the IMMOBLIzer option?
now a real answer , not guessing... just facts, if above true.
1:shorted wires to the pump (end to end ,long)
2;wrong amp fuse. not spec. (the one blown)
3: a shorted pump.
4: fuel pump relay shorted.
5: some fuses on cars (most) run other things too, not just a pump (not this case, it seems
no fuse number stated or engine size)

6: tank dry and this burned up the pump as all do. like that. no gas.? in tank.
7: pump clogged.and impeller jammed.

now Ill read the FSM pages on topic for you.
ok,on the schematic page,3.25
there is no such fuse, in uSA 2004,
its gets power on both engines from the IG1-b1 fuse
fuse eb f15, engine bay = eb
why not tell
that was 3.2
next the 3.5DI (a totally different setup)
ill pretend that next
if eb12 fuse blew (engine bay fuse f12) marked pump
that means, the pump is bad or the pump controller is shorted.
so unplug pump, if fuse holds its the pump
if not?, its the controller
here is proof on the 3.1

try mitchels.
its all there.
no books. ? well, read this,

http://www.eautorepair.net/Marketing/Default.asp




What would cause the fuse to keep blowing on the f - 26046168-fl3daiq2yrajyvah2fqqnein-3-0.jpgphotos sux here.

  • Anonymous Jan 13, 2016

    in real shop we see all facts
    no engine was stated so cant wax savvy much.
    we see ahh the pump runs ,for 5min then blows the fuse.
    we then scope the (lab scope)the pump + wire
    and look at commutator hashs.(noise)
    we can see shorted motor armatures, easy
    even see pumps that work now, but will fail soon.
    pulling the tank is not fun.
    so we check pump currents (ammeter)
    and check the controller if opted.
    and all related parts, for sorts (looking works)

  • Anonymous Jan 13, 2016

    on many many cars, see connectors run hot
    to pump even mid body
    turn brown,the black,then melt and its now shorted, good pump.
    caused by corrosion. and real poor factory connectors then. (poor or no water seals)

×

Thomas Perkins

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Isuzu Master 15,088 Answers
  • Posted on Jan 09, 2016
Thomas Perkins
Isuzu Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Feb 12, 2010
Answers
15088
Questions
0
Helped
3385375
Points
54869
Ad

5 Related Answers

stevenhurc

Steve Hurc

  • 459 Answers
  • Posted on Jul 03, 2009

SOURCE: I need advice on installing a new fuel pump 1992 Isuzu Rodeo

fuel tank has to be removed to remove fuel pump sender unit. make sure tank is near empty so its not as heavy to remove
some models have two round rings on top of tank, one is sender unit (for gauge) the other incorporates the fuel pump
others have one round ring which is both in one
remove the one near middle section of tank
be carefull not to bend float arm for sender unit if twin type (sender & fuel pump in one)

Ad
emissionwiz

Marvin

  • 85242 Answers
  • Posted on Dec 05, 2009

SOURCE: 2008 Ford F450 fuel pump relay fuse keeps blowing.

the fuel pump and radio are not on the same circuit, most liokely the fuel pump is shorted, that is the most common cause, get under the truck and disconnect the fuel pump connector at the tank, if the fuse doesn't blow then u need a new pump.

jturcotte

Jeffrey Turcotte

  • 8991 Answers
  • Posted on Jul 19, 2011

SOURCE: Fuel pump fuse constantly blowing

Hi, the fuse comes after the relay and only powers the pump. Therefore, the likely problem is your pump motor having shorted windings, sorry. :o(
There is a way to test the pump before replacing, but you would need an ammeter. Disconnect the pump connector and use a jumper wire from battery positive in series with a high current or shunted ammeter that can handle at least 20 amps. Connect the meter to the pump and run it just long enough to get the amperage reading. The pump motor is on the gray wire, and make sure the black wire is grounded to get the pump to come on. The current should be less than about 15 amps. A good shop can run this test for about $40. The cost of a new pump will be many hundreds, so you might want to be sure it's bad before replacing. A new pump is $270 at Autozone, and labor to replace the pump will be several hours. Some shops will discount the price of testing the pump if you have to pay to replace it. Please let me know if you have any questions and thanks for using FixYa.

jturcotte_1954.gif

sakthikumar

  • 12 Answers
  • Posted on Aug 01, 2012

SOURCE: 20 amp fule pump fuse keeps blowing on my isuzu rodeo 2004 v6 it will run for a while then it will blow also when i turn truck on it takes a while for it to starts it just cranks then kicks on

Better you use correct fuse and note there is no loose contacts between the fuse and its connection

Anonymous

  • 104 Answers
  • Posted on Oct 17, 2012

SOURCE: What could be the cause of my 1994 Isuzu Rodeo to keep blowing the #1 fuse for the tail lights and dash lights?

More likely coming from the tail lite area. Check all bulbs, replace if the filament looks black, even if it works. Next look underneath car for wire(s) hanging or broken and grounding out on chassis or other metal. Must be something shorting the circuit to ground or a bulb drawing too many amps.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

2004 Isuzu Rodeo. Bypass immobilization feature.

Question edited and add maker.
Question moved to model category.

The first thing to do is always reset the security system and engine immobilizer. If that doesn't work, you find a local auto electrician. Their pro grade scan tool computer will interrogate the electrical systems and check for DTCs.

https://www.google.com/search?q=2004+isuzu+rodeo+immobilizer+reset

..
0helpful
1answer

2003 Isuzu Rodeo RA utility keeps blowing a fuse labelled EDM. What is that one for please?

Question edited for clarity, add maker.
Question moved to model category.

The is no 'EDM' fuse. Do you mean 'ECM'?

Engine Control Module, the engine main computer that makes everything work.

Isuzu Rodeo / Amigo (1998-2004) fuses and relays

Fuse-Box.info https://fuse-box.info > isuzu > isuzu-rodeo-amigo-199...

Here you will find fuse box diagrams of Isuzu Rodeo / Amigo 1998, 1999, 2000, 2001, 2002, 2003 and 2004, get information about the location of the fuse ...

..
0helpful
1answer

Fuel pump fuse hot in fuse box under hood and fuel pump doesn't go on

most likely a fuel pump that has taken a dump. isuzu uses typical crappy gm/ac delco/dephi parts. you would need to drop the fuel tank to replace the fuel pump.
1helpful
1answer

How can you tell your fuel pump is going bad in a 2003 Isuzu rodeo

Place a pressure gauge in the fuel line check the reading while slowly crimping the return line if the pressure starts to rise the pumps ok. a partly blocked filter can over load a pump and cause it to fail or shorten its life.
0helpful
1answer

How can you tell if your pump is going bad 2003 Isuzu rodeo

check fuse holder contacts. what else stops when fuel pump fuse breaks? check that circuit.
0helpful
3answers

Why does the 20amp fuse for the fuel pump keep popping?

rodeo or rodeo SPORT?
2.2 or 3.2 engine> not even a cylinder count....
i wish all problems were this simple. (easy with ammeter)
the load is SHORTEd, the fuse saved the fire.
x2 all above answers
but keep in mind some fuses run more that one thing, ill check.

20amp fuse (no label) no engine option stated, must be the 6ve1, v6 twin cam.
fuel systems vary by (engine type)
not the 3.5L vin Y engines. 2.2 or 3.2L>?
fuse EB12, Engine bay fuse blows, 20a, fuel pump.

so pull these conn.
H-15 first
then if ok, (no blow)
H-25: if not blow now the pump is shorted
or the wire from H25 to F1 is ground to the frame.
wire inspections are first. on that path.
i use a EB12 , circuit breaker and mag ammeter to find this fast.
ask.



2.2L
25112994-qvzg5ivccfb4p0rjgycwet1k-2-0.jpg
0helpful
1answer

Why dose my fuel pump fues keep blowing

check the wiring from the fuse to the pump for broken insulation that is earthing out the wire and causing a dead short. Check for screws .pinched wires under mounts, melted wires on exhaust, shorting out in connections.
1helpful
2answers

Fuse to fuel pump keeps blowing

sounds like a bad fuel fuel pump or a wire chafe someplace on its way to the pump
0helpful
1answer

No power to fuel pump on 1992 izuzu rodeo

check ground under car behind fuel tank its grounded on the frame make sure it getting good connection,fuel pump relay is bad or bad wire from pump to fuse box.
Not finding what you are looking for?

419 views

Ask a Question

Usually answered in minutes!

Top Isuzu Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Are you an Isuzu Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...