At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
The Passlock family has two basic relearn procedures-a ten-minute procedure and a thirty-minute procedure-and which one you use depends on the system and what components have been replaced.
The ten-minute procedure involves trying to start the engine. If nothing happens or the engine starts and dies, the security light will be flashing. Wait ten minutes. The flashing light should go off or illuminate without flashing. When it does, turn the ignition off, wait twenty seconds, and then try to start the engine. If it starts and runs, everything is okay. If you get the same result as previously-nothing happens or the engine starts and dies with the security light flashing-wait ten more minutes.
You will now begin the thirty-minute relearn procedure, which is just the ten-minute procedure repeated three times. After turning the ignition off for the third time and waiting for twenty seconds, the engine should start and run. If it doesn't, there may still be something wrong with the system.
After the learn procedure is completed and the engine is running, the security light may stay on steady for a few minutes and then go off-this is normal. Depending on the system, replacement of key components will necessitate that a relearn procedure be completed. These include the ignition lock cylinder, Powertrain Control Module (PCM), Body Control Module (BCM), or Instrument Panel Cluster (IPC) ............ .Logic lock-up is an internal software issue within a control module which may be cleared by disconnecting and reconnecting the affected module (re-booting the system).
Electronic control modules can develop internal software issues which can cause erratic or no operation of the affected module. In most cases the module can be restored to proper operation by electrically disconnecting and reconnecting the affected module, just as you would reboot your home computer when it begins acting strangely.
Repeated Logic Lock-up failures of the same module would normally warrenty replacement of the affected module.
If the motor gets hot and cuts off and will not start for a period of time the problem would be the crank sensor. The sudden cut off and starting right back up can be due to dirty battery cable connections. Remove them from battery and clean all three of them with a wire brush and replace both bolts.
Do you get a check engine light? If so, read the codes with a scanner and chase down the clues. Does the PCM match the car and engine? Was the original engine a 3.8L? 5 to 10 minutes is not very long for an engine to cool down appreciably. Hopefully, the PCM codes will indicate whether the missing problem is fuel or ignition related.
try with the key on engine off press the gas pedal 3 times within 5 seconds. wait up to a minute and see if the oil change light start flashing and goes out.
The ignition switch on that model is rated @ 50amps. When I was driving my 2001 Regal LS (at 120,000 miles) and used the turn signal, the engine would die, when I switched the turn signal off, the engine ran. So I replaced the ignition switch, and all is well.
×