Where is the power distribution center for the blower

1 Answer

Layla Daniels

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Scholar:

An expert who has written 20 answers of more than 400 characters.

  • Expert 76 Answers
  • Posted on Dec 03, 2015
Layla Daniels
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Scholar:

An expert who has written 20 answers of more than 400 characters.

Joined: Dec 03, 2015
Answers
76
Questions
0
Helped
68041
Points
207

This is a common failure on 1999-2004 WJ models with the AZC (Automatic Zone Control) system. The connector on the blower motor control module overheats, resulting in intermittent or no operation of the blower motor. Mopar released a connector harness repair kit to fix the problem. The damaged connector is cut off and new wires are spliced into place. Only the green wires from the kit are used. One end of each of the 3 green wires goes into the new connector end that is provided. When inserting the wires into the connector, the locking spring tabs should be on the bottom. There is a gray plastic retainer that is then installed around the three wires that were just inserted into the connector.

1 Related Answer

Anonymous

  • 1 Answer
  • Posted on Dec 06, 2008

SOURCE: blower motor not working 1994 jeep cherokee

Sounds like your blower motor rheostat needs to be replaced. I'm about to replace mine for the second time. Fan just quits working altogether when the rheostat goes.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Heater fan 98 jeep cherokee not blowing

This should be a really simple fix if you posses a automotive test lamp to check the circut of the blower motor.

If you have a test lamp, ground the connector terminal on the fram of the vehicle, prob the tan and black wire at the blower motor and the light should come on when turning the switch to high speed, check at the blower motor connector. if you have power then you may have a defective B/M.

Also check fuse #46 at the power distribution center under the hood.

hope this helps.

Rodney
1helpful
1answer

Wheres the fuse box for the ciggerette lighter fuse

The fuse for the blower also powers the cigar lighter it is fuse F in the engine compartment power distribution center.
3helpful
1answer

What fuse operates the blower on my 1999 jeep cherokee? Where does the fuse go on the fuse panel?

Fuse #1 in the Power Distribution Center under the hood, it is a 40A fuse.
1helpful
1answer

Does the 2006 dodge magnum have more than two sets of fuses?

THERE ARE JUST TWO.
Power Distribution Centers/FUSE BOXES
1. Front Power Distribution Center
A power distribution center is located in the engine
compartment. This center contains fuses and relay

2. Rear Power Distribution Center
There is also a power distribution center located in the
rear compartment under the spare tire access panel. This
center contains fuses and relays.
Opening The Access Panel
Rear
0helpful
1answer

Which fuse is for the blower motorSuggested Sites

Fuse 1-40 amp fuse in power distribution center
0helpful
1answer

89 BMW 325i Relay

The blower motor relay is located in behind the climate control center mounted to the ac box.The window relays are located in the power distribution center under the hood number k-5 and k-7.
0helpful
1answer

Wipers turn signals and ac/heater not comming on

looks like they are on more than one fuse. your passenger compartment fuse box is down below your dash panel on drivers side between brake pedal and left side kick panel. the heater a/c fuse is a 25 amp fuse, should be fuse 6. the wipers are fed through a 4.8 amp circuit breaker which might be in the same fuse box, or not. your car also has a power distribution center under the hood. if you don't get anywhere with the fuses in the passenger compartment, look in the power distribution center. chrysler doesn't always share lots of info and i can only look up part of the wiring diagram. can't find anything about turn signals, my guess is that fuse is in power distribution box. hope that helps
0helpful
2answers

Blower motor not working 1994 jeep cherokee

It sounds like you have an issue with your fuse block. Pull the fuse for the radio and remove the buzzer. see if this changes the situation.
0helpful
1answer

Blower motor won't work

In some models the relay is in the power distribution center in the engine compartment, they should be marked, if not your owners manual may have info.
Not finding what you are looking for?

173 views

Ask a Question

Usually answered in minutes!

Top Jeep Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

john h

Level 3 Expert

29494 Answers

Are you a Jeep Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...