Question about 1986 Isuzu Pickup

Open Question

Fan blower motor does not work

Replaced all relays and blower motor still does not run

Posted by Anonymous on

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 261 Answers

SOURCE: Heater Fan/Blower does not work.

what you need is a blower motor resistot

Posted on Dec 04, 2008

  • 7353 Answers

SOURCE: Blower motor on 96 Isuzu Rodeo does not blow on

if fuses are good, check for power at blower motor, when truck is running and a/c on. the resistor and the switch provide ground, so the blue/white wire should have power, and the blue/black wire should have NO power, if it does have power, then most likely the resistor is bad. if it has no power and the motor doesnt run, the motor is bad.

Posted on Oct 20, 2009

Testimonial: "I will give that a try.. and post the results.."

  • 395 Answers

SOURCE: My blower fan dosen't work even after checking all

It sounds like the fan control switch is faulty or that the connector on the rear of the switch is not making proper contact. It may also be the blower resistor but when any of the the resistors fail, you usually can still get high speed to operate. T o access the switch you will have to remove part of the dash front panel so that you can get to the rear of the switch to check the connector and remove / replace switch which is usually a snap in setup..
You could also check the resistor block for proper connection. The Blower Fan Resistor Block is usually located in the air ducting adjacent to the Blower Fan. The Resistor Block consists of 3 or 4 coils of special resistance wire attached to terminals which connect to the wiring that comes from the fan switch and then to the Blower Fan. The block is on the output side of the fan unit so that the airflow from the fan past the coils inside the duct assists in preventing them from overheating and burning out.
As you already have replaced the fan motor you will know where to look for the resistor block. To replace, remove the multi-pin connector and then undo the screws holding in the block. Check air duct for leaves and dirt which may have caused the coils to fail. Replacement is the reverse procedure

Posted on Nov 07, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fan is not running


First check the fuse in the fuse box .
It also depends on witch fan /engine cooling fan /Blower motor fan.
Engine fans will have a relay more so then a blower motor .
The differences is this the blower draws more power and runs on a different ckt then the engine controls .So you can use the blower motor with out the engine running key on .
You don't say witch one you are having the problem with so I will try to explain both .
Most of the time both have relays and fuse's .The heater fan works on HI only off the relay so the relay is good if it works on HI.
The relay for the fan to cool the engine is different it controls all speeds do to temp change its cold some times has to handle more information .The relay the one thing they both have in common is the connections tend to get corroided Most of the time you can unplug and clean the plug in connectors to fix the issue

Jul 09, 2016 | Cars & Trucks

1 Answer

02 sunfire


If the 30amp blower fuse has power, and you can run power to the blower motor and it runs, I would say its the blower relay or the control switch on the dash. The control switch provides power to turn the blower relay on. The fan switch provides the ground circuit.

Feb 27, 2014 | Pontiac Sunfire Cars & Trucks

2 Answers

Heater fan not working


Smack it and see if it comes on. If it does then the motor brushes are bad. If it does not come on, check the fuses. If the fuses are ok, check the voltage on the plug to the motor.

Feb 06, 2014 | 2001 Dodge Durango

1 Answer

Dodge Stratus R/T fan doesn't come on while car is running and car is getting hot.


FAN NOT WORKING


It can be issue with faulty motor or its faulty fan control relay.


Bother are to be inspected.

Test volt at fan relay and fan motor.

-------------

For more help, I suggest you to go through the troubleshooting links mentioned below:-----

Click the link below: ------

How to replace Cooling Fan on Acura Car models?

http://repairhelpcenter.blogspot.com/2011/11/how-to-replace-cooling-fan-on-acura-car.html

--------------

OBD Code P1490 low speed fan relay ckt open-short

http://schematicsdiagram.blogspot.com/2012/11/obd-code-p1490-low-speed-fan-relay-ckt.html

---------------

Engine cooling components working?

http://repairhelpcenter.blogspot.com/2011/11/engine-cooling-components-working.html

----------

How does Vehicles Engine cooling system works?

http://repairhelpcenter.blogspot.com/2011/11/how-does-vehicles-engine-cooling-system.html

---------------

Hyundai Sonata cooling fan not working

http://schematicsdiagram.blogspot.in/2012/02/hyundai-sonata-cooling-fan-not-working.html

-------------

Fuel pump relay and cooling fan relay troubleshooting on 1997 ford thunderbird?

http://repairhelpcenter.blogspot.com/2011/10/fuel-pump-relay-and-cooling-fan-relay.html

--------------

Fan belt routing diagram for 2004 Volkswagen Jetta?

http://carbeltrouting.blogspot.com/2011/12/fan-belt-routing-diagram-for-2004.html

---------

Timing belt, drive belt, serpentine belt, accessory belt, fan belt, engine belt routing diagrams for all types of car models?

http://carbeltrouting.blogspot.in/2012/02/timing-beltdrive-beltserpentine.html

-------------

A/C, heater, defroster fan, not working?

http://technoanswers.blogspot.in/2012/02/ac-heater-defroster-fan-not-working.html

---------

Blower fan not running on Isuzu trooper?

http://technoanswers.blogspot.in/2012/02/blower-fan-not-running-on-isuzu-trooper.html

---------

How to replace blower motor fan assembly on 2000 GMC Yukon?

http://repairhelpcenter.blogspot.com/2012/01/how-to-replace-blower-motor-fan.html

----------

Heater AC or defroster fan not working on KIA?

http://technoanswers.blogspot.in/2012/02/heater-ac-or-defroster-fan-not-working.html

------------

These will help.

Thanks.

Nov 27, 2012 | Cars & Trucks

3 Answers

Fan won't work


It can be issue with faulty motor or its faulty fan control relay.
Bother are to be inspected.Test volt at fan relay and fan motor.-------------
For more help,i suggest you to go through the troubleshooting links mentioned below:-----Click the link below:------

How to replace Cooling Fan on Acura Car models?

http://repairhelpcenter.blogspot.com/2011/11/how-to-replace-cooling-fan-on-acura-car.html
--------------

OBD Code P1490 low speed fan relay ckt open-short
http://schematicsdiagram.blogspot.com/2012/11/obd-code-p1490-low-speed-fan-relay-ckt.html
---------------

Engine cooling components working?

http://repairhelpcenter.blogspot.com/2011/11/engine-cooling-components-working.html

----------

How does Vehicles Engine cooling system works?

http://repairhelpcenter.blogspot.com/2011/11/how-does-vehicles-engine-cooling-system.html

---------------

Hyundai Sonata cooling fan not working

http://schematicsdiagram.blogspot.in/2012/02/hyundai-sonata-cooling-fan-not-working.html

-------------

Fuel pump relay and cooling fan relay troubleshooting on 1997 ford thunderbird?

http://repairhelpcenter.blogspot.com/2011/10/fuel-pump-relay-and-cooling-fan-relay.html
--------------

Fan belt routing diagram for 2004 Volkswagen Jetta?

http://carbeltrouting.blogspot.com/2011/12/fan-belt-routing-diagram-for-2004.html
---------

Timing belt, drive belt, serpentine belt, accessory belt, fan belt, engine belt routing diagrams for all types of car models?

http://carbeltrouting.blogspot.in/2012/02/timing-beltdrive-beltserpentine.html
-------------

A/C, heater, defroster fan, not working?

http://technoanswers.blogspot.in/2012/02/ac-heater-defroster-fan-not-working.html
---------

Blower fan not running on Isuzu trooper?

http://technoanswers.blogspot.in/2012/02/blower-fan-not-running-on-isuzu-trooper.html
---------

How to replace blower motor fan assembly on 2000 GMC Yukon?

http://repairhelpcenter.blogspot.com/2012/01/how-to-replace-blower-motor-fan.html
----------

Heater AC or defroster fan not working on KIA?

http://technoanswers.blogspot.in/2012/02/heater-ac-or-defroster-fan-not-working.html
------------These will help.Thanks.

Nov 27, 2012 | Cars & Trucks

3 Answers

Where is the blower motor relay on the 1994 Ford Econoline. The fan is going one speed - SLOW. I replaced the blower motor, because it was squealing, but that never solved the problem. I'm thinking it's...


On your vehicle, if it works on low speed, that eliminates the fuse, the blower motor relay and the blower motor resistor. All of the parts of the resistor must bee good for it to work on low. The relay supplies power to the motor and the controls provide the ground, so if the motor runs at all, it is not the relay or the fuse. The only thing left is the switch. Fords are bad about burning the wire connector that conects to the switch. You will most likely have to replace the switch and the connector. Both of these parts are widely avaiable at most aftermarket parts stores.

Jan 15, 2011 | Ford E-Series Cars & Trucks

2 Answers

The heater fan is not working. Is it a fuse?


fuses are the easy thing to check just pull one and look at it if you see a burned spot replace it, checking relays and blower motor resesters and blower motors are harder if you dont know how to do it. there best left to a shop to check.

Dec 16, 2010 | 1999 Plymouth Voyager

1 Answer

Blower working on top 2 settings but no air comeing from vents


Hi

Thanks for using FixYa. The possible causes due to which the blower is not working normally are fuse, blower resistor or a bad blower motor. Test the voltage at the blower with a test light. Please check the motor relay switch fuse under the dashboard. Use a multi meter to measure ohms for continuity. If these are fine, bypass the blower motor relay switch to make sure blower motor is running fine. Motor relay switch is right next to radiator fan relay switch under the hood. Pull out the blower motor relay switch to see 4 female pin holes. Test the relay switch using a 12 volts power source and a multi meter to measure continuity. If fan works after jumping the pin holes, then blower motor is fine but relay switch may be faulty. You may also need to replace the blower motor resistor. If still the problem persists, then you need to replace the blower motor.

Please do rate the solution and revert for further assistance.


Thanks
Rylee

Aug 09, 2009 | 1997 Honda Civic

2 Answers

Inside Fan Relay location


replace blower motor switch on dash

Dec 18, 2008 | 1998 GMC Sierra

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

15 people viewed this question

Ask a Question

Usually answered in minutes!

Top Isuzu Experts

yadayada
yadayada

Level 3 Expert

74945 Answers

Steve Hurc
Steve Hurc

Level 3 Expert

450 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22095 Answers

Are you an Isuzu Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides