DB9 roof failure


Could be failed motor, water gets in around that area and can't escape. Begins to corrode worm gear.
Sometimes the ambient temp sensor can interfere with opening roof, like give false readings then locks roof thinking it's too hot or cold.
As an emergency, you can close roof manually (see in your manual for instructions) all the tools you need are in the cars toolkit.
Resetting the windows can sometimes fix it and check the fuses. It's not uncommon for these cars to leave showroom with some incorrect fuses.

Oct 10, 2016 | Aston Martin DB9 Cars & Trucks

1 Answer

Sunroof will not close. Was working fine earlier today


The roof opening panel assembly uses an integrated motor and module to operate the roof opening panel. The roof opening panel motor and module are installed new as an assembly. The roof opening panel is an electronically operated glass panel that can be opened or closed by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor/module. The soft-stop function is controlled by the roof opening panel motor/module. The roof opening panel has 3 modes of operation, manual mode, express open and tilt. The express open feature is activated when the switch is pressed momentarily. The tilt feature is activated when the tilt switch is depressed. These functions are controlled by the roof opening panel motor/module.
Visual Inspection Chart Mechanical Electrical
  • Roof opening panel
  • Roof opening panel frame
  • Roof opening panel drain hoses
  • Roof opening panel lifter assemblies
  • Roof opening panel water trough
  • Roof opening panel rear trough guides
  • Roof opening panel air deflector assembly
  • Roof opening panel seal
  • Roof opening panel shield
  • Smart junction box (SJB) circuit breaker 47 (30A)
  • Circuitry
  • Accessory delay relay
  • Roof opening panel switch
  • The roof opening panel does not open or close - one direction only
  • Circuitry
  • Roof opening panel switch
  • Roof opening panel motor assembly
  • Go To Pinpoint Test E .
PINPOINT TEST E: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE Test Step Result / Action to Take E1 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES FOR OBSTRUCTIONS OR DAMAGE
  • Check the roof opening panel lifter assemblies for obstructions and damage.
  • Are the roof opening panel lifter assemblies OK?
Yes
GO to E2 .

No
REMOVE all obstructions and REPAIR any damage. If lifter assemblies cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel Frame in this section. TEST the system for normal operation. E2 CHECK THE ROOF OPENING PANEL WATER TROUGH AND REAR TROUGH GUIDES
  • Check the water roof opening panel water trough and rear trough guides for any loose obstructions.
  • Are the roof opening panel water trough and rear trough guides installed securely and free from obstructions?
Yes
GO to E3 .

No
REMOVE all obstructions from the roof opening panel water trough and install securely. SECURE the rear trough guides or INSTALL new roof opening panel rear trough guides if damaged. REFER to Roof Opening Panel Rear Trough Guide in this section. TEST the system for normal operation. E3 VERIFY THE ROOF OPENING PANEL ADJUSTMENT
  • Verify the roof opening panel is adjusted correctly.
  • Is the roof opening panel adjusted correctly?
Yes
GO to E4 .

No
ADJUST the roof opening panel. REFER to Roof Opening Panel Alignment - Horizontal Adjustment and Roof Opening Panel Alignment - Height Adjustment in this section. TEST the system for normal operation. E4 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR INITIALIZATION
    NOTE: The roof opening panel motor initialization procedure must be done when repairs are carried out on any part of the roof opening panel assembly, including whenever the roof opening panel motor/module has been removed from the roof opening panel assembly, a new roof opening panel motor/module has been installed or when a new roof opening panel assembly has been installed. Refer to Roof Opening Panel Motor Initialization in this section.
  • Carry out the Roof Opening Panel Motor Initialization procedure. Refer to Roof Opening Panel Motor Initialization in this section.
  • If the concern still present?
Yes
GO to E5 .

No
The system is operating correctly. The roof opening panel motor/module was uninitialized. E5 CHECK THE POWER WINDOWS
  • Key in ON position.
  • Verify the power windows operate.
  • Do the power windows operate?
Yes
GO to E6 .

No
REFER to Section 501-11 to diagnose the accessory delay relay circuit. E6 CHECK THE ROOF OPENING PANEL SWITCH
  • Carry out the roof opening panel switch component test. Refer to Wiring Diagrams Cell 149 for schematic and connector information.
  • Did the roof opening panel switch pass the component test?
Yes
GO to E7 .

No
INSTALL a new roof opening panel switch. TEST the system for normal operation. E7 CHECK CIRCUIT CBP47 (GN/BU) FOR VOLTAGE
  • Key in OFF position.
  • Disconnect: Roof Opening Panel Motor/Module C922.
  • Key in ON position.
  • Measure the voltage between roof opening panel motor/module C922-4, circuit CBP47 (GN/BU), harness side and ground.
    s7j~tr~en~file=a0083978.gif~gen~ref.gif
  • Is the voltage greater than 9 volts but less than 16 volts?
Yes
GO to E8 .

No
VERIFY the smart junction box (SJB) circuit breaker 47 (30A) is OK. If OK, REPAIR the circuit. TEST the system for normal operation. E8 CHECK CIRCUIT GD143 (BK/VT) FOR AN OPEN
  • Key in OFF position.
  • Measure the resistance between roof opening panel motor/module C922-3, circuit GD143 (BK/VT), harness side and ground.
    s7j~tr~en~file=a0084276.gif~gen~ref.gif
  • Is the resistance less than 5 ohms?
Yes
GO to E9 .

No
REPAIR the circuit. TEST the system for normal operation. E9 CHECK CIRCUITS CPR37 (YE/GY), CPR39 (VT/WH) AND CPR40 (YE/OG) FOR AN OPEN
  • Disconnect: Roof Opening Panel Switch C930.
  • Measure the resistance between the roof opening panel motor/module C922-1, circuit CPR40 (YE/OG), harness side and roof opening panel switch C930-8, circuit CPR40 (YE/OG), harness side. Measure the resistance between roof opening panel motor/module C922-2, circuit CPR39 (VT/WH), harness side and roof opening panel switch C930-11, circuit CPR39 (VT/WH), harness side. Measure the resistance between roof opening panel motor/module C922-5, circuit CPR37 (YE/GY), harness side and roof opening panel switch C930-14, circuit CPR37 (YE/GY), harness side.
    s7j~tr~en~file=n0054600.gif~gen~ref.gif
  • Are the resistances less than 5 ohms?
Yes
GO to E10 .

No
REPAIR the circuit. TEST the system for normal operation. E10 CHECK FOR CORRECT ROOF OPENING PANEL MOTOR/MODULE OPERATION
  • Disconnect the roof opening panel motor/module connectors.
  • Check for:
    • corrosion.
    • pushed-out pins.
  • Connect all roof opening panel motor/module connectors and make sure they seat correctly.
  • Operate the system and verify that the concern is still present.
  • Is the concern still present?
Yes
CHECK the jumper harness between the vehicle harness and the roof opening panel for open or shorted circuits. If the jumper harness is not OK, INSTALL a new jumper harness between the vehicle harness to the roof opening panel motor/module. Otherwise, INSTALL a new roof opening panel module/motor. REFER to Roof Opening Panel Motor in this section. TEST the system for normal operation.

No
The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.

May 08, 2016 | 2008 Ford Expedition El

1 Answer

Sunroof opens on its own, when driving, just opens about 10th of an inch, you can push on it and it lifts also


it sounds as though the actual glass roof section has come loose from the frame that allows the roof to slide back and forth , try opening the roof half way and see if there are any securing screws/bolts from the glass roof edge to the frame , i've tried to get a schematic but have'nt found one yet , will forward one when i do , hope this helps

Jun 28, 2015 | 2006 Ford Expedition

1 Answer

Chrysler sebring roof wont open


Look under the back seat to see if there is any oil . Sometimes the hydrolic rams that move the top will leak fluid. If there is oil refill the fluid may help get the top open, but the ram will need to be replaced.

Jan 23, 2013 | 2008 Chrysler Sebring Convertible

1 Answer

On my 1998 mercedes benz sl600 i cant get the convertable top to open. i have replaced two of the struts for the roof and now my roof wont open. is there a way to resync the roof or am i just doing so


The top is controlled by you guessed it a computer module, have the dealer test that with a scan tool. The top is very complex in the control end, not simple like the old Mustangs I used to fix

Jun 08, 2012 | Cars & Trucks

1 Answer

I have a 2004 mini cooper convertible. The roof opens to half way and will then flash red if i want it ti close all the way, All windows shut initally, but now when closing the roof the driver side rear...


I am not sure what you are trying to do. But if the problem is that the roof will only open to the first stage, sun roof, and no further, the problem is the package shelf in the trunk.

If the package lid gets pushed up and is not pushed back to it's normal position, the roof will fail to open completely. If you lift the bottom of the roof at the boot, there are levers on either side to release the bottom edge of the roof, you can make certain that the package shelf is seated correctly. Once the shelf is seated, the roof will open in all of it's glory.

Apr 20, 2011 | 2004 Mini Cooper

1 Answer

Electric windows are fine the roof gets half way


If the top is half way down that means that the trunk is open and should be touching the trunk switch to continue the process. The switch must be bad and it is inside the rear right fender close the the stop light

Jul 25, 2010 | 1999 Mercedes-Benz SLK

1 Answer

My sun roof doesn't work well


I would open the sunroof COMPLETELY , clean tracks , and lubricate tracks as far back as you can. Operate the roof back and forth a few times. This should help

May 14, 2009 | 1995 Lincoln Continental

1 Answer

Roof stuck half open.


There's a hidden side pannel that you pry open. It's located on the drivers side of the side-dash. Basically open the drivers side door and try to pry open the side of the dash console. It's right inside there with all the fuses and things.

Jul 22, 2008 | 2003 Audi A4 Cabriolet

Not finding what you are looking for?
2006 Peugeot 307 CC Logo

Related Topics:

51 people viewed this question

Ask a Question

Usually answered in minutes!

Top Peugeot Experts

Colin Stickland
Colin Stickland

Level 3 Expert

22246 Answers

mike hayward

Level 2 Expert

279 Answers

lloyd cole

Level 2 Expert

250 Answers

Are you a Peugeot Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...