Question about 2005 Ford Taurus

1 Answer

Heater in 2005 ford taurus blows warm then cold

When the heater starts it warm air coming out inafew minutes it blows cold

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Cheetah:

    An expert who has answered 20 or more questions within one hour.

    Night Owl:

    An expert who has answered 10 or more questions between 12 midnight and 6am on the same day.

  • Expert
  • 159 Answers

Check vent door operation

Posted on Dec 28, 2013

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 68 Answers

SOURCE: Heater blows cold air

change the heater core

Posted on Dec 21, 2008

  • 141 Answers

SOURCE: heater on ford 2003 ford pick up blows cold air

on the evap box there is a control mtr that switches the hot cold door. these mtrs are prone to failure. the other problem that i have seen is that the door breakes in side the evap box and that means removing the box to replace the door . if i remeber correctly you may have to slide the dash back to gain assces to the control mtr to test it good luck

Posted on Dec 22, 2008

alicantecoli
  • 22156 Answers

SOURCE: Ford Expedition 2002 Front Heater blows cold air below 45 MPH

impeller is made of plastic on teh water pump and its slipping and spinning on the shaft renew before weather warms up as engine will overheat

Posted on Jan 01, 2009

  • 104 Answers

SOURCE: heater blows cold air have replaced the thermostat

sounds like the controller went bad use temp checker see what your temp is at inlet of heater core from hose

Posted on Sep 08, 2009

emissionwiz
  • 76118 Answers

SOURCE: 2000 Ford Taurus heater blows cold air ?

this problem is caused by a part called the "temperature control blend door actuater motor" this litttle motor drive moves the door that diverts air over the heater core or AC evaporator core, when it fails it almost alwys fails in the AC only position, u will need to have the motor drive replaced

Posted on Oct 16, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

2002 Ford Taurus, Heater blows cold air?


What have you checked so far ?
Radiator full of coolant ? Heater hoses getting hot ?

Feb 23, 2015 | 2002 Ford Taurus

1 Answer

Ford taurus 2005, no air condition or heat


Blend door motor likely, located behind center of the dash.

Feb 22, 2014 | 2005 Ford Taurus

1 Answer

No heat from vents


As per your problem mentioned. There are few solved help links to troubleshoot these problems. Go through the list and Click the link below:----

2000 Toyota Avalon: No heat on Passenger Side?

http://whatisbyme.blogspot.in/2012/05/2000-toyota-avalon-no-heat-on-passenger.html

------------

No heat on Oldsmobile Silhouette?


http://technoanswers.blogspot.in/2012/02/no-heat-on-oldsmobile-silhouette.html

------------

Heater blows cold?

http://schematicsdiagram.blogspot.in/2012/02/heater-blows-cold.html

-----------

Heat blows cold on drivers side and hot on passenger side?

http://schematicsdiagram.blogspot.com/2011/12/heat-blows-cold-on-drivers-side-and-hot.html

----------

Hot air on the driver's side vents only?

http://repairhelpcenter.blogspot.com/2012/01/hot-air-on-drivers-side-vents-only.html

--------------

Temperature gauge does not move and no heat when heater is ON?

http://technoanswers.blogspot.com/2012/01/temperature-gauge-does-not-move-and-no.html

-----------

1992 Toyota Camry: A/C Control light Flashing and A/C not Blowing Cold?

http://technoanswers.blogspot.in/2012/04/1992-toyota-camry-ac-control-light.html

--------------


No heat, blower blows only cold?

http://technoanswers.blogspot.in/2012/02/no-heatblower-blows-only-cold.html
----------

Ford F150 Ac only blows through defrost vents?

http://technoanswers.blogspot.com/2012/01/forf-f150-ac-only-blows-through-defrost.html

----------

Dodge A/C come out of defrost vents only?

http://technoanswers.blogspot.com/2012/01/dodge-ac-come-out-of-defrost-vents-only.html

---------

Ac vacuum line on dodge cummins?

http://technoanswers.blogspot.com/2012/01/ac-vacuum-line-on-dodge-cummins.html

---------

Ford ranger AC blows cold through defrost vents instead on cabin vents?

http://technoanswers.blogspot.com/2012/01/ford-ranger-ac-blows-cold-through.html

----------

2005 Chrysler PT Cruiser: A/C Blows Warm?

http://whoisbyme.blogspot.in/2012/06/2005-chrysler-p8t-cruiser-ac-blows-warm.html


-------------

2009 Mercury Grand Marquis: A/C blows Cold From Defrost Vent Only?

http://whoisbyme.blogspot.in/2012/06/2009-mercury-grand-marquis-ac-blows.html

-----------

AC not blowing through Vents on 2007 Chevy Trailblazer?

http://schematicsdiagram.blogspot.in/2012/04/ac-not-blowing-through-vents-on-2007.html

----------

Passenger side temperature is warm air out of dash vents?

http://schematicsdiagram.blogspot.in/2012/04/passenger-side-temperature-is-warm-air.html

----------


These will help.

Thanks.

Nov 28, 2012 | 2006 Ford Taurus

1 Answer

Air conditioner not blowing cold air intermittently


you need a ac charge or the heater control valve is bad also check the compressor

May 30, 2012 | 2001 Ford Taurus

1 Answer

1999 ford taurus se 155thousand miles, 3.0 V6


sounds like your thermostat is stuck open, if its takes a very long time for the engine to warm up and you get nothing but cold air from your heat then thats the first place i would start.

May 21, 2010 | 1999 Ford Taurus

1 Answer

No heat air is blowing cold


First you have to identify what causes the problem.
To do this you have to:
1) When engine is cold check the level of coolant. If it is low fill it up.
2) Start engine and check if engine reaches regular temperature. If your engine is not heated enough it means your thermostat does not work properly and should be replaced.
3) If engine temperature is normal, then check the temperature of pipes that go to/from heater core. These pipes are located up the fire wall (easier access is from the passenger side). If pipe/pipes are cold (even engine is worm) it means you heater core is plugged and should be flushed. Keep in mind, flushing the whole cooling system is different from flushing heater core.
4) If pipe/pipes are hot/warm, turn off the fan, switch controller to the hot position, wait for 3-4 minutes and turn on the fan. Note if the cold air blows first or warm air blows first but it cools down in 5-10 seconds. If the air blows cold than it is most probably the problem with blend door or blend door actuator.
5) If air blows warm first and then cools down, then while running engine and remaining the transmission in PARKING position, press on the gas pedal until your engine reaches 3,000 RPM. Check if your heater blows warm/hot air. If it does, then your water pump does not work properly and should be replaced. If the air still cold, I would suggest to flush the heater core.

Oct 22, 2009 | 1998 Ford Taurus

1 Answer

MY 1998 FOR TARUS HEATER WILL NOT WORK.WAS DRIVING


It is most probably the problem with blend door or blend door actuator. But just in case I would suggest to follow the entire procedure:

First you have to identify what causes the problem.
To do this you have to:
1) When engine is cold check the level of coolant. If it is low fill it up.
2) Start engine and check if engine reaches regular temperature. If your engine is not heated enough it means your thermostat does not work properly and should be replaced
3) If engine temperature is normal, then check the temperature of pipes that go to/from heater core. These pipes are located up the fire wall (easier access is from the passenger side). If pipe/pipes are cold (even engine is warm) it means you heater core is plugged and should be flushed. Keep in mind, flushing the whole cooling system is different from flushing heater core.
4) If pipe/pipes are hot/warm, turn off the fan, switch controller to the hot position, wait for 3-4 minutes and turn on the fan. Note if the cold air blows first or warm air blows first but it cools down in 5-10 seconds. If the air blows cold than it is most probably the problem with blend door or blend door actuator.
5) If air blows warm first and then cools down, then while running engine and remaining the transmission in PARKING position, press on the gas pedal until your engine reaches 3,000 RPM. Check if your heater blows warm/hot air. If it does, then your water pump does not work properly and should be replaced. If the air still cold, I would suggest flushing the heater core.

Oct 17, 2009 | 1998 Ford Taurus

1 Answer

Heater not working


First you have to identify what causes the problem.
To do this you have to:
1) When engine is cold check the level of coolant. If it is low fill it up.
2) Start engine and check if engine reaches regular temperature. If your engine is not heated enough it means your thermostat does not work properly and should be replaced.
3) If engine temperature is normal, then check the temperature of pipes that go to/from heater core. These pipes are located up the fire wall (easier access is from the passenger side). If pipe/pipes are cold (even engine is warm) it means you heater core is plugged and should be flushed. Keep in mind, flushing the whole cooling system is different from flushing heater core.
4) If pipe/pipes are hot/warm, turn off the fan, switch controller to the hot position, wait for 3-4 minutes and turn on the fan. Note if the cold air blows first or warm air blows first but it cools down in 5-10 seconds. If the air blows cold than it is most probably the problem with blend door or blend door actuator.
5) If air blows warm first and then cools down, then while running engine and remaining the transmission in PARKING position, press on the gas pedal until your engine reaches 3,000 RPM. Check if your heater blows warm/hot air. If it does, then your water pump does not work properly and should be replaced. If the air still cold, I would suggest flushing the heater core.

Oct 17, 2009 | 1998 Ford Taurus

2 Answers

Heater blows cold air ac blows warm air


Your problem is the air temp control blend door actuator is defective and not controlling temp u set. to change/access this part the dash assembly must be removed from the car.

Mar 24, 2009 | 1998 Ford Taurus

Not finding what you are looking for?
2005 Ford Taurus Logo

147 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ford Experts

yadayada
yadayada

Level 3 Expert

76109 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

fordexpert

Level 3 Expert

5520 Answers

Are you a Ford Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...