Question about Cars & Trucks

Open Question

Where is fan motor relay on 05 pontiac pursuit tried bloewer motor resister but still only one speed now and then

Posted by Anonymous on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 18 Answers

SOURCE: cooling fan relay placement 05 pacifica

IF YOU OPEN THE HOOD ON THE RIGHT SIDE THERE IS A SQUAR BOX THAT SITS RIGHT NEXT TO THE BATTERY OPEN THAT BOX AND LOOK UNDER THE PART YOU OPEN AND IT HAS A DIAGRAM AND THE NUMBER WHERE IT GOES

Posted on Dec 29, 2008

  • 3640 Answers

SOURCE: coolant fan not coming on, change motor, relay, censor & fuse sti

if the fans are not broken, here is a way to check them--- disconnect fans at wiring connection, then run a wire from positive on fans to positive post on battery,then run other side to ground if nessesary. if the fans are ok they will turn on. if not the coolant temp sensor is bad. or a short in wiring.

Posted on Aug 30, 2009

  • 7353 Answers

SOURCE: Blower motor on 96 Isuzu Rodeo does not blow on

if fuses are good, check for power at blower motor, when truck is running and a/c on. the resistor and the switch provide ground, so the blue/white wire should have power, and the blue/black wire should have NO power, if it does have power, then most likely the resistor is bad. if it has no power and the motor doesnt run, the motor is bad.

Posted on Oct 20, 2009

Testimonial: "I will give that a try.. and post the results.."

  • 323 Answers

SOURCE: I have a 2001 chevy S-10 pickup and recently lost

You'll figure it out you came this far, sound like you know what your doing

Posted on Jan 16, 2010

  • 262 Answers

SOURCE: 1997 Pontiac Grand Prix GT; Elec problem with fan

Replace the blower resistor that is mounted next to the blower motor on the passenger side of the vehicle.
This will restore correct blower operation and I suspect it is also back-feeding voltage resulting in your electrical issues.
Two screws hold the blower resistor into the heater case and it is very easy to replace.
Good luck

Posted on Mar 12, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

A/c relay location for 1999 ford exployer


Ac/clutch relay should b under hood
I'm assuming u mean blower motor resister behind glove box area..fan speed has no relay/fuse..just control unit/blend doors/blower motor basically

m

Sep 02, 2014 | Cars & Trucks

2 Answers

I have a 2008 Ford Edge, the a/c gets cold, but the fan runs at diff speeds when it wants to and sometimes not at all. I have replaced the blower motor, resister & blower motor relay. The problem still...


try running your fan motor w/o the ac being on, ie: defrost, heat etc..

If the problem with fan speed persists, try replacing the fan speed selector switch. FYI FREON was Dupont's version of R12 refrigerant which hasn't been made in decades. Your car uses R134a, not freon.

Jul 01, 2014 | Cars & Trucks

1 Answer

84 pontiac fiero 2.5l previous owner cut the factory wire harness and wired in a single pole relay. Now the two speed fan only runs when the engine gets to temp. need diagrams or someone to explain how to...


what you have to know is the ECM in those year start the injection . Coolant fan work by a relay and the relay is control by ECM a ground to relay. Find out the wire for A/C to relay.then find a + wire for current to relay then power from relay to coolant fan.if you want two speed to coolant fan you need at least 3 wires at coolant fan motor.

Sep 16, 2013 | Pontiac Cars & Trucks

1 Answer

IS GM tech2 available on my Cadillac year 1996?


GM Tech 2 support for on-board diagnostics on all GM systems 1992 thru 2011.The following GM vehicles utilize the CAN interface:

05 Buick Allure (3.6L)
05 Buick LaCrosse (3.6L)
05 Buick Rainier (5.3L)
04-05 Buick Rendezvous (3.6L)
04-05 Cadillac CTS (3.6L)
04-05 Cadillac SRX (3.6L / 4.6L)
04-05 Cadillac XLR (4.6L)
05 Cadillac STS (3.6L / 4.6L)
05 Chevrolet Cobalt (2.2L)
05 Chevrolet Corvette (6.0L)
05 Chevrolet Equinox (3.4L)
05 Chevrolet TrailBlazer (5.3L)
05 Chevrolet SSR (6.0L)
04 Chevrolet Malibu (Body/Chassis only)
05 Chevrolet Malibu (3.5L)
05 GMC Envoy (5.3L)
05 Pontiac G6 (3.5L)
05 Pontiac GTO (6.0L)
05 Pontiac Pursuit (2.2L)

Jul 03, 2013 | Cars & Trucks

2 Answers

Blower motor speed not working


This is usually due to 1 of 3 possible problems.

  1. Bad blower motor resistor - attaches to blower motor and regulates fan speeds. Not uncommon to lose 1 speed at a time until you get stuck with only 1 speed
  2. Bad blower motor
  3. Bad heater control module - less likely but still possible the module is bad and the whole unit requires replacing

Oct 16, 2011 | 2000 Kia Sportage

1 Answer

On my wife's 2008 Pontiac Vibe, the heater fan does not come on. No one remembers it stopping, but when I drove it yesterday, it was not working at all. I have checked any related fuses, and they are...


it could be a bad blower motor resister that controls fan speed depending on what fan setting you have set the dash switch on.it could also be the blower motor itself that needs to be replaced.with the blower on try tapping the motor and see if it tries to start.if it tries or starts to work then the motor will need replacing.

May 09, 2011 | 2005 Pontiac Vibe

1 Answer

Front blower not working on 2003 Pontiac Montana. Tried new blower motor, but did not work. What else could it be?


there is a blower motor resister located around the electrical connection of the blower fan usally one or two speeds quit on the fan when they go bad make sure that the connecter is in good shape and not burned on the plug

Mar 07, 2011 | 2003 Pontiac Montana

1 Answer

Pontiac montana 2000 general fan (all air-hot and cold) doesnt function changed the fuse and now only works from settings 3-5 and change the heater relay is my fuse labelled 'air" not the right...


there is a blower motor resister which controls fan speed i believe its located pass side of dash by blower motor has one plug about 5 wires red ,orange .blue yellow

Feb 09, 2011 | 2001 Pontiac Montana

1 Answer

Only have 1 speed on HVAC fan


the fan relay(resister) that control fan speed is probably burned out.When this occurs it will only blow at high speed because its getting 12volts directly to the fan

May 25, 2009 | 2004 Pontiac Vibe

1 Answer

05 ford excurson front blower fan works on high only.


it's the resister in the blower motor case.

Resistor Removal
  1. Disconnect the electrical connector.
  1. Remove the screws and remove the A/C blower motor resistor.

4209c39.gif
Installation


  1. Follow the removal procedure in reverse order.

Apr 01, 2009 | 2005 Ford Excursion

Not finding what you are looking for?
Cars & Trucks Logo

Related Topics:

16 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cars & Trucks Experts

yadayada
yadayada

Level 3 Expert

75822 Answers

Colin Stickland
Colin Stickland

Level 3 Expert

22156 Answers

Randy Ohler

Level 3 Expert

14585 Answers

Are you a Car and Truck Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...